LAMINOSS DENTAL IMPLANT
Device Facts
| Record ID | K982925 |
|---|---|
| Device Name | LAMINOSS DENTAL IMPLANT |
| Applicant | Impladent , Ltd. |
| Product Code | DZE · Dental |
| Decision Date | May 18, 1999 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The LAMINOSS® Osteocompressive Implant System consists of a one-piece and twopiece immediately-loaded screw implants for the maxillary and mandibular arches to support fixed or removable prostheses.
Device Story
LaminOss Osteocompressive Implant System comprises one-piece and two-piece screw implants; designed for immediate loading in maxillary and mandibular arches; supports fixed or removable dental prostheses; used by dental clinicians in clinical settings; provides structural foundation for prosthetic restoration; benefits patients by enabling immediate functional replacement of missing teeth.
Technological Characteristics
Screw-type dental implant system; available in one-piece and two-piece configurations; intended for osseous integration in maxillary and mandibular arches.
Indications for Use
Indicated for patients requiring support for fixed or removable prostheses in the maxillary or mandibular arches.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Related Devices
- K053478 — ENDOSSEOUS DENTAL IMPLANT SYSTEM · Northern Implants, LLC · Apr 5, 2006
- K160106 — LUNA DENTAL IMPLANT SYSTEM · Shinhung Mst Co., Ltd. · Aug 26, 2016
- K060957 — MODIFICATION TO BLUE SKY BIO DENTAL IMPLANT SYSTEM · Blue Sky Bio, LLC · May 5, 2006
- K040946 — ANKYLOS DENTAL IMPLANT SYSTEM · Friadent GmbH · Jul 1, 2004
- K081751 — ADIN DENTAL IMPLANTS SYSTEM · Adin Dental Implants System, Ltd. · Dec 19, 2008