SIMPLER TOADSTOOL MINI IMPLANT

K092674 · Pan Global Implant · DZE · Dec 28, 2009 · Dental

Device Facts

Record IDK092674
Device NameSIMPLER TOADSTOOL MINI IMPLANT
ApplicantPan Global Implant
Product CodeDZE · Dental
Decision DateDec 28, 2009
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3640
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Simpler Toadstool Mini Implant is intended to be used as an artificial root to provide immediate long term or transitional support for overdentures.

Device Story

Simpler Toadstool Mini Implants are narrow-diameter (2.5mm) endosseous dental implants used as artificial roots for overdenture support. Manufactured from 6/4 titanium alloy, they feature a one-piece design with a flattened, toadstool-shaped abutment and hexagonal top. Implants are grit-blasted and acid-etched; some models include a hydroxylapatite (HA) coating on the threaded portion. During clinical use, the hex ball abutment fits into a keeper with a rubber o-ring within the prosthesis to reduce loading and improve retention. Used by dental professionals in surgical settings, these implants provide a minimally invasive alternative to conventional implants for stabilizing soft tissue-supported overdentures in edentulous or partially edentulous patients. They support immediate loading when primary stability is achieved, benefiting patients by providing stable, removable prosthetic support.

Clinical Evidence

No clinical data provided. Substantial equivalence is based on bench testing and comparison to predicate devices regarding materials, surface treatment, and fatigue performance.

Technological Characteristics

Narrow diameter (2.5mm) endosseous dental implants. Material: 6/4 Titanium alloy (90% Ti, 6% Al, 4% V). Surface: Grit-blasted and acid-etched; optional hydroxylapatite (HA) coating on threads. Design: One-piece with flattened toadstool-shaped abutment and hexagonal top. Lengths: 10mm, 13mm, 15mm, 18mm. Mechanical retention via rubber o-ring in prosthesis.

Indications for Use

Indicated for long-term intra-bony support of soft tissue-supported overdentures in partial or fully edentulous patients (mandible/maxilla). Suitable for immediate loading given good primary stability and appropriate occlusal load. Also indicated for temporary support. Contraindications: local infection, vascular impairment, uncontrolled diabetes, chronic high-dose steroids, clotting disorders, anticoagulant therapy, metabolic bone disease, or systemic disorders affecting bone/wound healing.

Regulatory Classification

Identification

An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.

Special Controls

*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ 172 3. SUMMARY K092674 510(K) 092674 Dr. Harold Bergman, President Pan Global Implant Corp. Simpler Implants #404 1023 Wolfe Ave. DEC 2 8 2009 Vancouver, BC V6H 1V6 Phone: 604 736 9890 Fax: 604-736-9747 Contact: Karen Bergman. QA Assurance Officer or Dr. Bergman, President Trade Name: Simpler Toadstool Mini Implant & Simpler Toadstool HA Mini Implant Common Name: Simpler Toadsfool Mini Implants & Simpler Toadstool Mini Implant Classification: Endosseous Dental Implants Leaally marketed devices to which S.E. is claimed K083886: Simpler Mini Implants K031106 : Imtec Sendax MDI and MDI plus K050586: Leone Implant System K70601: Mini Drive-Lock Implant Description The Simpler Toadstool Minis and the Simpler HA Toadstool Minis are Narrow Diameter implants. They are manufactured using 6/4 Titanium alloy 90% titanium 6% aluminum and 4% vanadium for strength. All implants are arit blasted and also acid etched and are available uncoated or coated with hydroxylapatite only on the threaded part of the implant. The diameter is 2.5mm and the lenaths are 10mm. 13mm, 15 mm and 18 mm in both the coated and uncoated implants. The implants are designed as one piece with a flattened toadstool shaped abutment with a hexagonal outline at the top of the implant. The flattened, hex ball fits into a keeper with a rubber o-ring placed in the prosthesis to reduce loading and to help with retention. Intended Use: The Simpler Toadstool Mini Implant is intended to be used as an artificial root to provide immediate long term or transitional support for overdentures. Indications for Use: The Simpler Toadstool Mini Implants and the Simpler HA Toadstool Mini Implants are intended to provide long term intra-bony applications for Soft Tissue Supported Over Dentures only. They are designed for immediate loading when there is good primary stability and an appropriate occlusal load. These implants may also be used for {1}------------------------------------------------ K092674 temporary soft tissue overdenture support for partial and fully edentulous restoration in the mandible and maxilla. They may be used as a minimally invasive surgical technique option for full or partial edentuloism as an alternative to more invasive surgery involving conventional implants Contraindications: Contraindications customary to the placement of any dental implants may be observed. These include, but are not limited to current local infection, vascular impairment, uncontrolled diabetes, chronic high doses of steroids, clotting disorders, current anticoagulant therapy, metabolic bone disease, and other metabolic or systemic disorders which will affect bone or wound healing. Excessive loading or placement of implants in inadequate bone may result in fracture. Complications: Possible complications with any oral reconstructive surgery include, infection, closure perforation, abscess formation, bone loss, pain soft tissue irregularities and additional complications associated with anesthesia and dental surgery. Summary of Testing: Simpler Toadstool Mini Implants do not introduce new issues for materials, surface treatment, fatigue testing and risk management that have not been addressed in all other approved Simpler Implants. {2}------------------------------------------------ Food and Drug Administration 10903 New Hampshire Avenue Document Control Room W-O66-0609 Silver Spring, MD 20993-0002 Dr. Harold Bergman Chief Executive Officer Pan Global Implant Corporation #404 1023 wolfe Avenue Vancouver, British Columbia CANADA V6H 1V6 DEC 2 8 2009 Re: K092674 Trade/Device Name: Simpler Toadstool Mini Implant, Simpler HA Toadstool Mini Implant Regulation Number: 21CFR 872.3640 Regulation Name: Endosseous Dental Implant Regulatory Class: II Product Code: DZE Dated: December 17, 2009 Received: December 22, 2009 Dear Dr. Bergman: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2- Dr. Bergman Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free. number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, Cinchin 0.2m Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ K092674 ( 1) ## 510(k) K092674 Device Name: Simpler Toadstool Mini Implant Simpler HA Toadstool Mini Implant ## Indications for Use: The Simpler Toadstool Mini Implants and the Simpler HA Toadstool Mini Implants are intended to provide long term intra-bony applications for Soft Tissue Supported Over Dentures only. They are designed for immediate loading when there is good primary stability and an minimal occlusal load. These implants may also be used for temporary soft tissue overdenture support for partial and fully edentulous restoration in the mandible and maxilla. They may be used as a minimally invasive surgical technique option for full or partial edentulism as an alternative to more invasive surgery involving conventional implants. Prescription Use X AND/OR Part 21 CFR 801 Subpart D) Over the Counter Use (21 CFR 801 Subpart C) ## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED ## Concurrence of CDRH, Office of Device Evaluation (ODE) Cunten her (Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices 4992674 510(k) Number:
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...