OPTIBAND LC

K032407 · Sybron Dental Specialties, Inc. · DYH · Oct 6, 2003 · Dental

Device Facts

Record IDK032407
Device NameOPTIBAND LC
ApplicantSybron Dental Specialties, Inc.
Product CodeDYH · Dental
Decision DateOct 6, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3750
Device ClassClass 2

Intended Use

The intended use of Optiband LC is as a light-cured orthodontic band cement that is designed for the attachment of orthodontic appliances to teeth.

Device Story

Optiband LC is a resin-based, fluoride-releasing orthodontic band cement. It is supplied as a single paste, eliminating the need for manual powder/liquid mixing or catalyst/activator blending. The material is light-cured, allowing for immediate placement of active archwires. It is formulated for high adhesion to enamel and metal surfaces to minimize band loosening and wash-out. The device is used by dental professionals in a clinical setting to secure orthodontic appliances. It offers higher tensile and compressive strength compared to traditional glass ionomer or zinc phosphate cements and lacks unpleasant taste or odor. Available in chromatic and blue shades.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Resin-based, fluoride-releasing orthodontic cement. Single-paste formulation. Light-cured. High tensile and compressive strength. Available in chromatic and blue shades. Class II device (21 CFR 872.3750).

Indications for Use

Indicated for the attachment of orthodontic appliances to teeth in patients requiring orthodontic treatment.

Regulatory Classification

Identification

A bracket adhesive resin and tooth conditioner is a device composed of an adhesive compound, such as polymethylmethacrylate, intended to cement an orthodontic bracket to a tooth surface.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ OCT = 6 2003 Section III - 510(k) Summary of Safety and Submitter: K032407 Sybron Dental Specialties, Inc. 1717 W. Collins Avenue Orange, California 92867 (714) 516-7484 - Phone (714) 516-7488 - Facsimile Colleen Boswell - Contact Person Date Summary Prepared: July 2003 ## Device Name: - Trade Name Optiband LC ● - Common Name -- Orthodontic Band Cement ● - Classification Name Bracket Adhesive Resin and Tooth Conditioner, per 2 i CFR & 872.3750 . ## Devices for Which Substantial Equivalence is Claimed: - 3M Unitek Dental Products Division, Transbond Plus . ## Device Description: The device is a resiri-based fluoride releasing band cement. It is a single paste so messy powder and liquid mixing is eliminated as well as inconsistent mixing of catalyst/activator type cements. Optiband LC achieves high strength following light cure allowing active archwires to be placed immediately. Optiband LC has higher tensile and compressive strength than glass ionomers or zinc phosphates and does not have an unpleasant taste or odor. It is specially formulated to have high adhesion to enamel and metal surfaces to reduce the chances of wash-out and loose bands. Optiband LC is offered in two shades, chromatic formula and blue formula. ## Intended Use of the Device: The intended use of Optiband LC is as a light-cured orthodontic band cement that is designed for the attachment of orthodontic appliances to teeth. ## Substantial Equivalence: Optiband LC is substantially equivalent to other legally marketed devices in the United States. Optiband LC functions in a manner similar to and is intended for the same use as Transbond Plus that is currently marketed by 3M Unitek Dental Products Division. {1}------------------------------------------------ DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/1/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo features a stylized depiction of a human face in profile, composed of three curved lines. The logo is surrounded by a circular border containing the text "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" in capital letters. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 OCT - 6 2003 Ms. Colleen Boswell Director, Corporate Compliance Sybron Dental Specialties, Incorporated 1717 West Collins Avenue Orange, California 92867 Re: K032407 Trade/Device Name: Optiband LC Regulation Number: 21 CFR 872.3750 Regulation Name: Bracket Adhesive Resin and Tooth Conditioner Regulatory Class: II Product Codes: DYH Dated: July 31, 2003 Received: August 04, 2003 Dear Ms. Boswell: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {2}------------------------------------------------ ### Page 2 - Ms. Colleen Boswell Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Chiu S. Lin, PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health {3}------------------------------------------------ # Section I - Indications for Use : | Ver/ 3 - 4/24/96 | | |--------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------| | Applicant: | Ormco Corporation | | 510(k) Number (if known): | K032407 | | Device Name: | Optiband LC | | Indications For Use: | | | Optiband LC Band Cement is a light-cured orthodontic bonding cement that is intended to be used for the attachment of orthodontic appliances to teeth. | | (Division Sign-Off) Division of Anesthesiology, General Hospital, Infection Control, Dental Devices | 510(k) Number: | K032407 | |----------------|---------| |----------------|---------| (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) (Per 21 CFR 801.109) (Optional Format 1-2-96)
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...