K030312 · Wieland Dental + Technik GmbH & Co. KG · EJT · Mar 26, 2003 · Dental
Device Facts
Record ID
K030312
Device Name
PORTA IMPLANT
Applicant
Wieland Dental + Technik GmbH & Co. KG
Product Code
EJT · Dental
Decision Date
Mar 26, 2003
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3060
Device Class
Class 2
Intended Use
Porta Implant is a gold-palladium-platinum ceramic alloy that can be used by dental technicians to fabricate dental appliances for patients. It is intended for manufacturing - Crowns - Short span bridges - Long span bridges - Removable partials and can be used for • Telescopic and milling work Porta Implant can be veneered with suitable dental ceramics as well as with dentalcomposites.
Device Story
Porta Implant is a gold-palladium-platinum ceramic alloy (97.6% noble metal content) used by dental technicians to fabricate dental restorations, including crowns, bridges, and removable partials. The alloy is designed for porcelain fusing, offering high sag resistance, making it suitable for implant supraconstructions. It is veneered with dental ceramics or composites. The device is used in dental laboratories; it provides a biocompatible, corrosion-resistant material for restorative dentistry, enabling the creation of durable, functional dental appliances for patients.
Clinical Evidence
No clinical data. Bench testing only; device complies with ISO 9693 and European directive 93/42/ECC.
Technological Characteristics
Gold-palladium-platinum ceramic alloy; 97.6% noble metal content. High sag resistance at porcelain fusing temperatures. Corrosion resistant. Complies with ISO 9693.
Indications for Use
Indicated for patients requiring dental restorations including crowns, short/long span bridges, removable partials, and telescopic/milling work. Intended for use by dental technicians to fabricate appliances.
Regulatory Classification
Identification
A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver, that is intended for use in the fabrication of cast or porcelain-fused-to-metal crown and bridge restorations.
Special Controls
*Classification.* Class II (special controls). The special control for these devices is FDA's “Class II Special Controls Guidance Document: Dental Noble Metal Alloys.” The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. See § 872.1(e) for availability of guidance information.
Predicate Devices
SMG-3 (Degussa-Ney)
Related Devices
K012827 — PORTA AURIUM, MODEL 2067 · Wieland Edelmetalle GmbH & Co. · Nov 1, 2001
K040672 — PORTA REFLEX · Wieland Dental + Technik GmbH & Co. KG · May 27, 2004
K031264 — PORTA PRESSOVER · Wieland Dental + Technik GmbH & Co. KG · Jun 12, 2003
K012828 — PORTA SMK 82, MODEL 2032 · Wieland Edelmetalle GmbH & Co. · Nov 1, 2001
K012835 — PORTA MAXIMUM, MODEL# 2066 · Wieland Edelmetalle GmbH & Co. · Nov 1, 2001
Submission Summary (Full Text)
{0}------------------------------------------------
K030312
## Premarket Notification 510(k)
# Porta Implant
### 5. 510 (k) Summary
| Submitter of 510(k): | Wieland Dental + Technik GmbH & Co. KG |
|----------------------|----------------------------------------|
| | Schwenninger Str. 13 |
| | D-75179 Pforzheim |
| | Germany |
| | Phone: +49-7231-3705-0 |
| Contact person: | Dr. Gerhard Polzer |
|-----------------|----------------------------------|
| Phone: | +49-7231-3705-219 |
| Fax: | +49-7231-357959 |
| e-mail: | gerhard.polzer@wieland-dental.de |
Date of Summary: 2003-01-27
PORTA IMPLANT Trade name:
Classification name: Product code: C.D.R section: Classification:
Alloy, gold based, for clinical use EJT 872.3060 Class II
| Legally marketed equivalent device: | SMG-3 (Degussa-Ney) |
|-------------------------------------|---------------------|
| 510(k) number: | Not known |
#### Device description
PORTA IMPLANT is a gold-palladium-platinum ceramic alloy with high contents of noble metals (97,6%) intended for dental technicians to fabricate dental restorations.
It has an indication for use which ranges from single crowns up to long span bridges with two or more pontics. At porcelain fusing temperatures, it has a high sagresistance and therefore it is suitable for manufacturing of implant supraconstructions.
PORTA IMPLANT is highly corrosion resistant and has an excellent biocompatibility. It fully complies to the international standard ISO 9693 and fulfills the essential requirements of the European directive 93/42/ECC concerning medical devices.
PORTA IMPLANT can be veneered with suitable dental ceramics and with dental composites.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a seal for the Department of Health & Human Services. The seal is circular and contains the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. In the center of the seal is a stylized image of an eagle with its wings spread.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 2 6 2003
Dr. Gerhard Polzer Director, Regulatory Affairs Wieland Dental + Technik GmbH & Co. KG Schwenninger Strasse 13 D-75179 Pforzheim GERMANY
Re: K030312
Trade/Device Name: Porta Implant Regulation Number: 21 CFR 872.3060 Regulation Name: Gold Based Alloys and Precious Metal Alloys for Clinical Use Regulatory Class: II Product Codes: EJT Dated: January 27, 2003 Received: January 30, 2003
Dear Dr. Polzer:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
Page 2 – Dr. Gerhard Polzer
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act): 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits vour device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801). please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on vour responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Susan Penner
Susan Runner, DDS, MA Interim Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
{3}------------------------------------------------
. Page 1 . c
Porta Implant DEVICE NAME :
(IF KNOWN)
INDICATIONS FOR USE:
NUMBER
510(k)
Porta Implant is a gold-palladium-platinum ceramic alloy that can be used by dental technicians to fabricate dental appliances for patients.
It is intended for manufacturing
- Crowns
- Short span bridges
- Long span bridges
- Removable partials
and can be used for
• Telescopic and milling work
Porta Implant can be veneered with suitable dental ceramics as well as with dentalcomposites.
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED.)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription Use (Per 21 CFR 801.109)
ﯩﺮ
OR
Over-The-Counter-Use (Optional Format 1-2-96)
Kai Muly for NSP
nesthesiology, General Hospital, ntrol lien
510(k) Number. K030312
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.