K020190 · Wieland Dental + Technik GmbH & Co. KG · EJT · Mar 13, 2002 · Dental
Device Facts
Record ID
K020190
Device Name
PORTADUR P 4
Applicant
Wieland Dental + Technik GmbH & Co. KG
Product Code
EJT · Dental
Decision Date
Mar 13, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3060
Device Class
Class 2
Intended Use
Portadur P 4 is a gold casting alloy that can be used by dental technicians to fabricate dental appliances for patients. It is intended for manufacturing Inlays/ Onlays Crowns Short span bridges Long span bridges Removable partials . and can be used for Telescopic and milling work
Device Story
Portadur P 4 is an extra-hard gold casting alloy (75.5% noble metal content) used by dental technicians to fabricate dental restorations. The alloy is processed via casting techniques to create dental appliances, including inlays, onlays, crowns, bridges, and removable partials. It is designed for high corrosion resistance and biocompatibility. The device is used in a dental laboratory setting by trained technicians. The final restoration is placed by a dentist to restore patient dental function and aesthetics.
Clinical Evidence
No clinical data. Substantial equivalence is based on material properties, compliance with international standard ISO 1562, and biocompatibility assessment.
Technological Characteristics
Extra-hard gold casting alloy; 75.5% noble metal content. Complies with ISO 1562. High corrosion resistance and biocompatibility. Form factor: casting alloy for dental laboratory use.
Indications for Use
Indicated for patients requiring dental restorations including inlays, onlays, crowns, short and long span bridges, removable partials, and telescopic or milling work.
Regulatory Classification
Identification
A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver, that is intended for use in the fabrication of cast or porcelain-fused-to-metal crown and bridge restorations.
Special Controls
*Classification.* Class II (special controls). The special control for these devices is FDA's “Class II Special Controls Guidance Document: Dental Noble Metal Alloys.” The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. See § 872.1(e) for availability of guidance information.
K012843 — PORTADUR P 2, MODEL #2031 · Wieland Edelmetalle GmbH & Co. · Nov 2, 2001
K023395 — PORTADUR P2 · Wieland Dental + Technik GmbH & Co. KG · Dec 11, 2002
K012831 — BIO PORTADUR, ORDER-NO.:2017 · Wieland Edelmetalle GmbH & Co. · Nov 1, 2001
K012827 — PORTA AURIUM, MODEL 2067 · Wieland Edelmetalle GmbH & Co. · Nov 1, 2001
K031264 — PORTA PRESSOVER · Wieland Dental + Technik GmbH & Co. KG · Jun 12, 2003
Submission Summary (Full Text)
{0}------------------------------------------------
Kozlod
## Premarket Notification 510(k)
## Portadur P 4
MAR 1 3 2002
# 5. 510 (k) Summary
Wieland Dental + Technik GmbH & Co. Submitter of 510(k): Schwenninger Str. 13 D-75179 Pforzheim Germany Phone: +49-7231-3705-0
| Contact person: | Dr. Gerhard Polzer |
|-----------------|----------------------------------|
| Phone: | +49-7231-3705-219 |
| Fax: | +49-7231-357959 |
| e-mail: | gerhard.polzer@wieland-dental.de |
2001-07-21
Date of Summary:
Trade name:
Portadur P 4
Classification name: Product code: C.D.R section: Classification:
Alloy, gold based, for clinical use EJT 872.3060 Class II
Legally marketed Harmony Line PF equivalent device:
510(k) number:
K950517
### Device description
Portadur P 4 is an extra-hard gold casting alloy with high contents of noble metals (75.5%), intended for dental technicians to fabricate dental restorations.
It has an indication which ranges from inlays/onlays and crowns up to long span bridges with two or more pontics and to removable partials. In addition, it is suitable for telescopic and milling work.
Portadur P 4 is highly corrosion resistant and has an excellent biocompatibility. It fully complies to the international standard ISO 1562 and fulfills the essential requirements of the European directive 93/42/ECC concerning medical devices.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle with its wings spread.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR 1 3 2002
Dr. Gerhard Polzer Director, Regulatory Affairs Wieland Dental + Technik GmbH & Co. KG Schwenninger Strasse 13 75120 Pforzheim, GERMANY
Re: K020190
Trade/Device Name: Portadur P 4 Regulation Number: 872.3060 Regulation Name: Gold-Based Alloys and Precious Metal Alloys for Clinical Use Regulatory Class: Class II Product Code: EJT Dated: January 18, 2002 Received: January 22, 2002
Dear Dr. Polzer:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{2}------------------------------------------------
# Page 2 - Dr. Gerhard Polzer
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must
comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4659. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Valclouth
Timothy Ilatowski Director Division of Dental, Infection Control, and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
#### Page 1 of 1
510(k) Number (if known): k020190
Portadur P 4 Device Name:_
Indications For Use:
- Portadur P 4 is a gold casting alloy that can be used by dental technicians to fabricate dental appliances for patients.
It is intended for manufacturing
- Inlays/ Onlays
- Crowns
- Short span bridges
- Long span bridges
- Removable partials .
and can be used for
Telescopic and milling work
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Susan Runse
(Division Sign-Off) Division of Dental, Infection Control, ENTSion or Bentul, Inneouting (9) 9) (1) 5100k) Number _
Prescription Use V (Per 21 CFR 801.109) ાર
Over-The-Counter Use__
(Optional Format 1-2-96
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.