Record IDK021969
Device NameCHROLOY
ApplicantNeirynck & Vogt NV
Product CodeEJH · Dental
Decision DateJul 30, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3710
Device ClassClass 2

Intended Use

Chroloy alloy is intended to be used by dentists and dental laboratories for the fabrication of custom made dental devices such as removable partial dentures.

Device Story

Chroloy is a base metal alloy used by dental professionals and laboratories to fabricate custom dental prosthetics, specifically removable partial dentures. The device serves as the raw material for casting or forming dental appliances. It is intended for prescription use only.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Base metal alloy classified under 21 CFR 872.3710 (Product Code: EJH).

Indications for Use

Indicated for use by dentists and dental laboratories for the fabrication of custom dental devices, specifically removable partial dentures.

Regulatory Classification

Identification

A base metal alloy is a device composed primarily of base metals, such as nickel, chromium, or cobalt, that is intended for use in fabrication of cast or porcelain-fused-to-metal crown and bridge restorations.

Special Controls

*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: Dental Base Metal Alloys.” The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. See § 872.1(e) for availability of guidance information.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular border with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the top half of the circle. Inside the circle is an emblem featuring a stylized depiction of three overlapping human figures. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUL 3 0 2002 Neirynck & Vogt NV C/O Mr. Josh Andrachek Vacalon Company, Incorporated 12960 Stonecreek Drive Pickerington, Ohio 43147 Re: K021969 Trade/Device Name: Chroloy Regulation Number: 872.3710 Regulation Name: Base Metal Alloy Regulatory Class: II Product Code: EJH Dated: June 17, 2002 Received: June 17, 2002 Dear Mr. Andrachek: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Page 2 - Mr. Josh Andrachek Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Victor A Timothy A. Ulatowski Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## Indications for Use Page 1 of 1 510(k) Number (if known): K021969 Device Name: Chroloy Indications for Use: Chroloy alloy is intended to be used by dentists and dental laboratories for the fabrication of custom made dental devices such as removable partial dentures. (Please do not write below this line- Continue on another page if needed) Prescription Use_ (Per 21 CFR 801-109) OR Over-the-counter Use _________________________________________________________________________________________________________________________________________________________ (optional; format 1-2-96) Susan Rurser (Division Sign-Off) Division of Dental, Infection Control, and General Hospital Devices 510(k) Number ________________________________________________________________________________________________________________________________________________________________
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...