Browse hierarchy: [Dental (DE)](/submissions/DE) → [Subpart D — Prosthetic Devices](/submissions/DE/subpart-d%E2%80%94prosthetic-devices) → [21 CFR 872.3540](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/872.3540) → NKJ — Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter

# NKJ · Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter

_Dental · 21 CFR 872.3540 · Class 1_

**Canonical URL:** https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/NKJ

## Overview

- **Product Code:** NKJ
- **Device Name:** Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
- **Regulation:** [21 CFR 872.3540](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/872.3540)
- **Device Class:** 1
- **Review Panel:** [Dental](/submissions/DE)

## Identification

An OTC denture cushion or pad is a prefabricated or noncustom made disposable device that is intended to improve the fit of a loose or uncomfortable denture, and may be available for purchase over-the-counter.

## Classification Rationale

Class I if the device is made of wax-impregnated cotton cloth that the patient applies to the base or inner surface of a denture before inserting the denture into the mouth. The device is intended to be discarded following 1 day's use. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 872.9. Class II (special controls) if the OTC denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended use of the device differs from that described in paragraph (b)(1) of this section. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9.

## Special Controls

*Classification.* (1) Class I if the device is made of wax-impregnated cotton cloth that the patient applies to the base or inner surface of a denture before inserting the denture into the mouth. The device is intended to be discarded following 1 day's use. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 872.9.(2) Class II (special controls) if the OTC denture cushion or pad is made of a material other than wax-impregnated cotton cloth or if the intended use of the device differs from that described in paragraph (b)(1) of this section. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. The special controls for this device are FDA's:
(i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical—Devices Part I: Evaluation and Testing,’ ” and
(ii) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits.”

## Recent Cleared Devices (0 of 0)

_No cleared devices on record._

---

**Source:** [https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/NKJ](https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/NKJ)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
