DX. Bond V Dental Bonding Adhesive

K232978 · Sino-Dentex Co., Ltd. · KLE · Sep 22, 2023 · Dental

Device Facts

Record IDK232978
Device NameDX. Bond V Dental Bonding Adhesive
ApplicantSino-Dentex Co., Ltd.
Product CodeKLE · Dental
Decision DateSep 22, 2023
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3200
Device ClassClass 2
Attributes3rd-Party Reviewed

Indications for Use

Bonding for all Classes of direct composite restoration Bonding for indirect procedures involving metal, porcelain and composite

Device Story

DX. Bond V is a multi-purpose dental bonding adhesive used for direct composite restorations, indirect procedures (metal, porcelain, composite), amalgam bonding, self-cure composite bonding, and orthodontic bracket bonding. The adhesive consists of methylmethacrylates and solvents. It is applied as a thin layer to the bonding area and polymerized via free radical initiation using blue light, forming a cross-linked polymer network. The device is used in dental clinics by dental professionals. The resulting bonding membrane provides a strong, solid interface for restorative materials, benefiting the patient by ensuring the retention and stability of dental restorations.

Clinical Evidence

Bench testing only. Biocompatibility testing conducted per ISO 10993-5 (cytotoxicity), ISO 10993-10 (sensitivity), ISO 10993-23 (irritation), ISO 10993-11 (acute systemic toxicity), and ISO 10993-3 (genotoxicity). Performance bench testing included film thickness (ISO 4049:2010), shear bonding (ISO/TS 11405:2015; ISO 29022:2013), light sensitivity (ISO 4049:2010), and microleakage (ISO/TS 11405:2015). Results demonstrated performance comparable to the predicate device.

Technological Characteristics

Resin-based dental bonding agent. Composition: BisGMA, HEMA, Ethylene dimethacrylate, Camphorquinone, Ethyl-4-dimethyl amino benzoate, acetone, and ethanol. Polymerization initiated by blue light. Complies with ISO 4049:2010 (film thickness, light sensitivity) and ISO/TS 11405:2015 (shear bonding, microleakage).

Indications for Use

Indicated for bonding all classes of direct composite restorations and indirect procedures involving metal, porcelain, and composite materials.

Regulatory Classification

Identification

A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted on the interior of a prepared cavity of a tooth to improve retention of a restoration, such as a filling.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food & Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is in blue and includes the letters "FDA" in a square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in a sans-serif font. September 22, 2023 Sino-Dentex Co., Ltd. % Prithul Bom Most Responsible Person Regulatory Technology Services, LLC 1000 Westgate Drive, Suite 510k Saint Paul, Minnesota 55114 Re: K232978 Trade/Device Name: DX. Bond V Dental Bonding Adhesive Regulation Number: 21 CFR 872.3200 Regulation Name: Resin tooth bonding agent Regulatory Class: Class II Product Code: KLE Dated: September 21, 2023 Received: September 21, 2022 Dear Prithul Bom: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely. # Michael E. Adjodha -S Michael E. Adjodha, M.ChE. Assistant Director DHT1B: Division of Dental and ENT Devices OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT and Dental Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ #### Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2023 See PRA Statement below. Submission Number (if known) K232978 Device Name DX. Bond V Dental Bonding Adhesive (Universal-003, Universal-005) Indications for Use (Describe) [ Bonding for all Classes of direct composite restoration [ Bonding for indirect procedures involving metal, porcelain and composite Type of Use (Select one or both, as applicable) Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ K232978 Image /page/3/Picture/1 description: The image shows the logo for DENTEX. The word "DENTEX" is written in a bold, sans-serif font and is blue. Below the word "DENTEX" is the Chinese translation of the word. To the right of the Chinese translation is the registered trademark symbol. DX. Bond V Dental Bonding Adhesives Traditional 510(k) Notification SINO-DENTEX CO.,LTD. Kxxxxxxx # 510 K SUMMARY ## 1. SUBMITTER INFORMATION | Applicant Information: | SINO-DENTEX CO.,LTD.<br>721Chenggong Road,<br>High-Tech Development District, Changchun,<br>Jilin P.R. China,130000<br>Email: dentex-ypt@163.com<br>Tel: (086) 18943173317<br>Fax: (086) 431-87855157 | |------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Manufacturer Contact: | SINO-DENTEX CO., LTD.<br>721Chenggong Road, High-Tech Development<br>District, Changchun, Jilin P.R. China,130000<br>Contact: Pengtao Yan<br>Owner Operator Number: 10083627<br>Facility Registration Number: 3018283083<br>Email: dentex-ypt@163.com<br>Tel: (086) 18943173317<br>Fax: (086) 431-87855157 | | Summary Preparation Date: | 8/25/2023 | | Type of 510(k) Submission: | Traditional 510 (k) | | 2. DEVICE DETAIL: | | | Device Classification Name:<br>Device Trade Name:<br>Common Name:<br>Model Number: | Agent, tooth bonding, resin<br>DX. Bond V Dental Bonding Adhesive<br>Dental Bonding Adhesive<br>Universal-003, Universal-005 | 21 CFR 872.3200 Regulation Number: {4}------------------------------------------------ Image /page/4/Picture/0 description: The image contains the logo for DENTEX. The word "DENTEX" is written in blue, block letters at the top of the image. Below the word "DENTEX" is the Chinese translation of the word, also written in blue. To the right of the Chinese translation is the registered trademark symbol. SINO-DENTEX CO.,LTD. | Regulation Medical Specialty: | Dental | |-------------------------------|----------| | Regulatory Class: | Class II | | Product Code: | KLE | ## 3. LEGALLY MARKETED PREDICATE DEVICE: | Device Classification Name: | Agent, tooth bonding, resin | |-------------------------------|-----------------------------| | Device Trade Name: | Scotchbond Dental Adhesive | | Common Name: | Dental Bonding Adhesive | | Regulation Number: | 21 CFR 872.3200 | | Regulation Medical Specialty: | Dental | | Regulatory Class: | Class II | | Product Code: | KLE | | 510 K: | K81380 | | Manufacture: | 3M | ## 4. DEVICE DESCRIPTION: DX. Bond V Dental Bonding Adhesive is a multi-purpose dental bonding adhesive for all classes of direct composite restoration as well as for indirect procedures involving metal, porcelain and composite. DX. Bond V is also used for amalgam, self- cure composite and orthodontic brackets bonding. DX. Bond V consists of methylmethacrylates and solvent. After applied to bonding area with thin layer, methylmethacrylates are initiated by free radical with blue light and then polymerized to form cross-linking polymer network resulting in solid and strong bonding membrane. The adhesive is dropped onto a mixing pad before application. ## 5. INDICATIONS FOR USE: 1.Bonding for all Classes of direct composite restoration 2.Bonding for indirect procedures involving metal, porcelain, and composite ## 6. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVCIE: Both Dentex DX. Bond V Dental Bonding Adhesive and the predicate device 3M Scotchbond Dental Adhesive have similar chemistry composition. Both use {5}------------------------------------------------ Image /page/5/Picture/0 description: The image shows a logo for a company called "DENTEX". The word "DENTEX" is written in blue, bold letters with a rounded rectangle around it. Below the word "DENTEX" are three Chinese characters, also in blue. To the right of the Chinese characters is the registered trademark symbol. #### SINO-DENTEX CO.,LTD. BisGMA, HEMA as main monomer, and Camphorquinone/ Ethyl-4-dimethyl amino benzoate as initiator system. The major difference is solvent and ethylene dimethacrylate monomer. Dentex DX. Bond V Dental Bonding Adhesive utilizes acetone/ethanol as the solvents and the predicate devices only has ethanol in it. Acetone/ethanol combination is more volatile for reduction of any residual solvent on bonding body which may decrease the curability of the adhesive. Both ethanol and acetone are common materials in dental application and evaporated in short time after application. Dentex DX. Bond V Dental Bonding Adhesive is added with Ethylene dimetharylate monomer which has been applied extensively in dental restorative materials for many years. Its major function is to dilute thick BisGMA. So, the difference has not affected the safety and effectiveness of the device. ## 7. PERFORMANCE DATA ### Biocompatibility testing DX. Bond V Dental Bonding Adhesive is considered a communicating device in long term contact with tissue/bone/dentin. A biological risk assessment and testing were conducted to assess the biocompatibility of the DX. Bond V: - Cytotoxicity tests (ISO 10993-5:2009) ● - Sensitivity Test (ISO 10993-10:2010) - Irritation Test (ISO 10993-23:2021) - Acute Systemic toxicity (ISO 10993-11:2017) ● - . Genotoxicity (ISO 10993-3:2014). The results of the biocompatibility testing and risk assessment demonstrates a low potential for an unacceptable adverse biological response from contact of the component materials of the device with the body. ### Non-clinical performance data Bench testing was conducted to determine the performance of the DX. Bond V compared to the predicate devices. The tests performed were: - Film thickness: ISO 4049:2010 ● - . Shear bonding: ISO/TS 11405:2015; ISO29022:2013 - Light sensitivity: ISO 4049:2010 ● {6}------------------------------------------------ Image /page/6/Picture/0 description: The image shows a logo for a company called "DENTEX". The word "DENTEX" is written in blue, bold letters with a rounded rectangle around it. Below the word "DENTEX" are three Chinese characters, also in blue. To the right of the Chinese characters is the registered trademark symbol. SINO-DENTEX CO.,LTD. - Microleakage: ISO/TS 11405:2015 ● Bench testing demonstrated the DX. Bond V Dental Bonding Adhesive met the relevant ISO standard requirement, where applicable, and performed comparably to the predicate devices for the parameters tested. #### Clinical performance data This section is not applicable. #### Electrical safety and electromagnetic compatibility (EMC) This section is not applicable. #### Software verification and validation testing This section is not applicable. #### Mechanical and acoustic testing This section is not applicable. ## 8. CONCLUSION REGARDING SUBSTANTIAL EQUIVALENCE The conclusions drawn from the bench and biocompatibility tests demonstrate that the proposed subject device is as safe, as effective, and performs as well as the legally marketed predicate device, 3M Scotchbond Dental Adhesive cleared under K813180.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...