← Product Code [KLE](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/KLE) · K051796

# CLEARFIL TRI-S BOND SINGLE DOSE (K051796)

_Kuraray Medical Kurashiki Plant · KLE · Aug 9, 2005 · Dental · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/KLE/K051796

## Device Facts

- **Applicant:** Kuraray Medical Kurashiki Plant
- **Product Code:** [KLE](/submissions/DE/subpart-d%E2%80%94prosthetic-devices/KLE.md)
- **Decision Date:** Aug 9, 2005
- **Decision:** SESE
- **Submission Type:** Traditional
- **Regulation:** 21 CFR 872.3200
- **Device Class:** Class 2
- **Review Panel:** Dental

## Intended Use

1) Direct restorations using light-cured composite resin 2) Cavity sealing as a pretreatment for indirect restorations 3) Treatment of exposed root surfaces 4) Core build-ups using light- or dual-cured composite resin

## Device Story

Resin-based dental adhesive system; composed of dimethacrylate monomers. Intended for application to prepared tooth cavities to improve restorative material retention. Supplied in single-dose disposable tips. Used by dental professionals in clinical settings. Applied to tooth structure to bond composite resins for direct restorations, indirect restoration pretreatment, root surface treatment, and core build-ups. Enhances clinical outcomes by improving marginal sealing and bond strength between tooth structure and restorative materials.

## Clinical Evidence

Bench testing only. Evaluated bond strengths between bovine tooth and composite resin, bovine dentin and core build-up composite resin, and marginal sealing compared to the predicate device. Results demonstrated substantial equivalence in effectiveness.

## Technological Characteristics

Resin-based dental adhesive; contains dimethacrylate monomers. Delivered via single-dose disposable tips. No electronic components, software, or energy sources. Sterilization method not specified.

## Regulatory Identification

A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted on the interior of a prepared cavity of a tooth to improve retention of a restoration, such as a filling.

## Predicate Devices

- Clearfil tri-S bond ([K042913](/device/K042913.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

[Clearfil tri-S bond Single dose, Kuraray Medical Inc.] AUG 9 - 2005

K051796

# 510(k) SUMMARY

1. Submitter

| 1) Name                     | KURARAY MEDICAL INC.                                                                                                                                                                        |
|-----------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| 2) Address                  | 1621 Sakazu, Kurashiki, Okayama 710-8622, Japan                                                                                                                                             |
| 3) 1. Contact person        | Masaya Sasaki<br>Dental Material Division, Kuraray Medical Inc.                                                                                                                             |
| 2. Contact person in U.S.A. | Satoshi Yamaguchi<br>Kuraray America Inc.<br>101 East 52nd Street, 26th Floor<br>New York, NY 10022<br>Telephone: (212)-986-2230 (Ext.115)<br>1-(800)-879-1676<br>Facsimile: (212)-867-3543 |
| 4) Date                     | October XX, 2004                                                                                                                                                                            |

#### 2. Name of Device

| 1) Proprietary Name    | Clearfil tri-S bond Single dose            |
|------------------------|--------------------------------------------|
| 2) Classification Name | Resin tooth bonding agent (21CFR 872.3200) |
| 3) Common/Usual Name   | Resin-based dental adhesive system         |

3. Predicate device

The predicate device is as follow; a) Resin Tooth Bonding Agent 1. Clearfil tri-S bond

by Kuraray Medical Inc. (K042913)

#### 4. Description for the premarket notification

This device is classified into the resin tooth bonding agent, CFR 21 Section 872.3200, because it is a device composed of materials such as dimethacrylate monomers intended to be painted on the interior of a prepared cavity of a tooth to improve retention of restorative materials.

{1}------------------------------------------------

## 5. Statement of the intended use

The intended use of this device is as follows. It is the same as that of Clearfil triS bond (K042913) manufactured by Kuraray Medical Inc.

| Indications for Use                                                                                                                                                                                                                   | Predicate device              |
|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-------------------------------|
| 1) Direct restorations using light-cured composite resin<br>2) Cavity sealing as a pretreatment for indirect<br>restorations<br>3) Treatment of exposed root surfaces<br>4) Core build-ups using light- or dual-cured composite resin | Clearfil tri-S bond (K042913) |

6. Statement of the safety and technological characteristics

#### 6-1. Safty

The ingredients and composition of this device are the same as that of Clearfil tri-S bond (K042913) and it only differs in that it is filled in single dose tips (disposable tips). Therefore this device is the same as the legally marketed predicate devices, Clearfil tri S bond, in respect of safety.

### 6-2. Technological characteristics

The bond strengths between bovine tooth and a composite resin, between bovine dentin and core build up composite resin and marginal sealing were evaluated in comparison with Clearfil tri-S bond . As to the result, this device is substantially equivalent to the legally marketed predicate devices, Clearfil tri-S bond, in effectiveness.

{2}------------------------------------------------

Image /page/2/Picture/1 description: The image shows the seal of the Department of Health and Human Services (HHS). The seal is circular and features the department's name around the perimeter. In the center is an abstract emblem resembling an eagle or bird-like figure, composed of curved lines. The overall design is simple and monochromatic.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

AUG 9 - 2005

Kuraray Medical, Incorporated C/O Mr. Satoshi Yamaguchi Kuraray America, Incorporated 101 East 52nd Street, 26th Floor New York, New York 10022

Re: K051796

Trade/Device Name: Clearfil™ tri-S Bond Single Dose Regulation Number: 21 CFR 872.3200 Regulation Name: Resin Tooth Bonding Agent Regulatory Class: II Product Code: KLE Dated: July 01, 2005 Received: July 12, 2005

Dear Mr. Yamaguchi:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{3}------------------------------------------------

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely vours.

Susan Runne

Chiu S. Lin, PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{4}------------------------------------------------

510(k) Number (if known):

K051796

Device Name: Clearfil tri-S bond Single dose

## Indications for Use

Clearfil tri-S bond Single dose is indicated for the following applications:

- 1) Direct restorations using light cured composite resin
- 2) Cavity sealing as a pretreatment for indirect restorations
- 3) Treatment of exposed root surfaces
- 4) Core build-ups using light- or dual-cured composite resin

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

| Concurrence of CDRH, Office of Device Evaluation (ODE) |
|--------------------------------------------------------|
|--------------------------------------------------------|

Prescription Use

OR

Over-The-Counter Use

(Optional Format 1-2-96)

Susan Gunn

(Division Sign-Off)
Division of Anesthesiology, General Hosp

Division of Anesthesiology, General Hospital, Infection Control, Dental Devices

510(k) Number:

---

**Source:** [https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/KLE/K051796](https://fda.innolitics.com/submissions/DE/subpart-d%E2%80%94prosthetic-devices/KLE/K051796)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
