K014027 · Kerr Dental Materials Center · KLE · Feb 22, 2002 · Dental
Device Facts
Record ID
K014027
Device Name
OPTIBOND SOLO PLUS 4
Applicant
Kerr Dental Materials Center
Product Code
KLE · Dental
Decision Date
Feb 22, 2002
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3200
Device Class
Class 2
Indications for Use
Optibond Solo Plus 4 is a self-etch primer designed to work in conjunction with a tooth bonding agent. Optibond Solo Plus 4 can be used for indirect situations, i.e., composite to enamel and/or dentin, composite repair, porcelain repair, composite to metal, amalgam sealing, post and core build-up materials, and indirect situations, i.e., veneers, onlays, inlays, crowns and bridges (used in conjunction with a resin luting agent).
Device Story
OptiBond Solo Plus 4 is a self-etch dental primer used in conjunction with a resin tooth bonding agent. It eliminates the need for separate phosphoric acid etching, reducing post-operative sensitivity and simplifying the bonding process. The device is applied by dental professionals in a clinical setting to prepare tooth surfaces for direct restorations (e.g., composite fillings, core build-ups) or indirect restorations (e.g., veneers, crowns, bridges). By conditioning the enamel and dentin, it facilitates the adhesion of restorative materials, potentially improving clinical outcomes and patient comfort.
Clinical Evidence
No clinical data provided; substantial equivalence is based on technological characteristics and intended use compared to the predicate device.
Technological Characteristics
Resin tooth bonding agent (Product Code: KLE). Self-etch primer chemistry. Designed for use with OptiBond Solo Plus adhesive and dual cure activator. Class II medical device.
Indications for Use
Indicated for dental patients requiring direct restorations (composite to enamel/dentin, composite/porcelain repair, composite to metal, amalgam sealing, post and core build-up) and indirect restorations (veneers, onlays, inlays, crowns, bridges) when used with a resin luting agent.
Regulatory Classification
Identification
A resin tooth bonding agent is a device material, such as methylmethacrylate, intended to be painted on the interior of a prepared cavity of a tooth to improve retention of a restoration, such as a filling.
Predicate Devices
Clearfil Liner Bond 2V (Kuraray America, Inc.)
Submission Summary (Full Text)
{0}------------------------------------------------
KO McQrz
Image /page/0/Picture/1 description: The image shows a logo with the letters 'sds' in a stylized, interconnected design. A curved line extends from the left, arcing over the letters to add a dynamic element. Below the letters, partial text is visible, suggesting the words 'DENTAL SPECIALIST' are present, though the beginning of the phrase is cut off.
## BRON DENTAL SPECIALTIES
FEB 2 2 2002
Section III - 510(k) Summary of Safety and Effectiveness
Submitter:
Sybron Dental Specialties, Inc. 1717 W. Collins Avenue Orange, California 92867 (714) 516-7484 - Phone (714) 516-7488 - Facsimile Colleen Boswell - Contact Person
December 2001
Date Summary Prepared:
#### Device Name:
11. 11
- Trade Name -- Optibond Solo Plus 4 .
- Common Name Resin Tooth Bonding Agent •
- Common Name -- Resin Tooth Bonding Agent, per 21 CFR § 872.3200 .
Devices for Which Substantial Equivalence is Claimed:
Kuraray America, Inc., Clearfil Liner Bond 2V .
## Device Description:
OptiBond Solo Plus 4 self-etch primer is designed for use with OptiBond Solo Plus adhesive of OptiBond Solo Plus 4 seti-etch primer is designior (in Unidose or bottle delivery), both a Class II
OptiBond Solo Plus adhesive with dual cure activator (in cubmission of a 5 OptiBond Solo Flus addiesIve will dadi care access by FDA following the submission of a 510(k)
device which were granted marketing clearance by Flaxed Solo Rus with Acity device which were grained marketing trearance of the or OptiBond Solo Plus will Activator,
premarket notification. When used with OptiBond Solo Plus or restorations. The self premarket notification. When used in the bonding of both direct restorations. The self-etch the self etch primer can be used in the bonumy of the bonding process. Some advantages
primer is used to eliminate the phosphoric acid etch separitive and an elimination of primer is used to enminate the phospilore actires and other of i
of using a self etch primer include reduction of post-operative sensitivity and an elimination of steps in the bonding process.
# Intended Use of the Device:
The intended use of Optibond Solo Plus 4 can be used for direct situations, i.e., composite to enamel The intended tise of Optional Solo I rus 4 can or assess to metal, annalgam sealing, post and bridges and/or dentin, composite repart, porcelan ropan, composite of theys, crowns and bridges
core build-up materials, and indirect situations, i.e., veneers, onlays, inlays, crown (used in conjunction with a resin luting agent).
## Substantial Equivalence:
Optibond Solo Plus 4 is substantially equivalent to other legally marketed devices in the United Optibond Solo Plus 4 is substantially equivalent volter regal, Inc. finctions in a maners similar to
States. The self-etching primer marketed by Kurray Marchal Materials Cen States. The self-etching primer marketed by Kultiray Princitus, and
800-537-7824 714-516-7400 1717 West Collins Avenue, Orange, CA 92800
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white circular seal. The seal contains the symbol of the Department of Health & Human Services, which is an abstract image of an eagle. The text around the seal reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA".
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
FEB 2 2 2002
Ms. Colleen Boswell Kerr Dental Materials Center Center A Division of Sybron Dental Specialties, Incorporated 1717 West Collins Avenue Orange, California 92867
Re: K014027
Trade/Device Name: Optibond Solo Plus 4 Regulation Number: 872.3200 Regulation Name: Resin Tooth Bonding Agent Regulatory Class: II Product Code: KLE Dated: December 4, 2001 Received: December 6, 2001
Dear Ms. Boswell:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general approvisions of the Act. The general controls provisions of the Act include contrements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting (1 will), it ind) 00 basyon in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies.
{2}------------------------------------------------
Page 2 - Ms. Boswell
You must comply with all the Act's requirements, including, but not limited to: registration I ou must compry with an are reseling (21 CFR Part 801); good manufacturing practice allu listing (21 CFR Pac 007), lacems (QS) regulation (21 CFR Part 820); and if requirences as set forth in als quality sion control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section I mis letter will anow you to ocelli manage you of substantial equivalence of your device to 310(K) promation nownloate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 II you desire specific ac not 10-10-10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and Othoo of Collightance are, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under nothication (21CF ICPart For 001997).
the Act may be obtained from the Division of Small Manufacturers, International and the Act may be counter its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Timothy A. Ulatowski
Timothy A. Ulatowski Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
Section I
Indications for Use Statement
Ver/3-4/24/96
Applicant: Kerr Dental Material Center
| <strong>Labels</strong> | <strong>Values</strong> |
|---------------------------|-------------------------|
| 510(k) Number (if known): | 2014027 |
Device Name: Optibond Solo Plus 4
Indications For Use:
Optibond Solo Plus 4 is a self-etch primer designed to work in conjunction with a tooth bonding agent. Optibond Solo Plus 4 can be used for indirect situations, i.e., composite to enamel and/or dentin, composite repair, porcelain repair, composite to metal, amalgam sealing, post and core build-up materials, and indirect situations, i.e., veneers, onlays, inlays, crowns and bridges (used in conjunction with a resin luting agent).
Susan Runs
(Division Sign-Off)
Division of Dental, Infection Control,
and General Hospital Devices,
| <strong>Labels</strong> | <strong>Values</strong> |
|-------------------------|-------------------------|
| 510(k) Number | K014007 |
(PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
(Per 21 CFR 801.109)
(Optional Format 1-2-96)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Report an issue or suggest a feature
Spot a broken citation, a wrong extraction, a missing document, or something you wish this app did? Tell us — no account needed.
or drag and drop files here
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the Tutorial button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.