ZINC PHOSPHATE CEMENT

K983018 · Medental Intl. · EMA · Oct 22, 1998 · Dental

Device Facts

Record IDK983018
Device NameZINC PHOSPHATE CEMENT
ApplicantMedental Intl.
Product CodeEMA · Dental
Decision DateOct 22, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3275
Device ClassClass 2

Indications for Use

Zinc phosphate cement is without any adhesive properties and is used as a luting agent. It is always referred to as a cement and is used for the attachment of indirect restorations and appliances to the teeth and for the cementation of inlays, crowns, bridges, facings, and orthodontic brackets.

Device Story

Zinc Phosphate Cement is a traditional dental luting agent consisting of a powder (zinc oxide, magnesium oxide) and a liquid (phosphoric acid, distilled water, alumina hydrate, zinc oxide). Used by dental professionals for the permanent attachment of indirect restorations and orthodontic appliances to teeth. The device functions as a mechanical luting agent without inherent adhesive properties. It is prepared by mixing the powder and liquid components and applied to the restoration or appliance before placement on the tooth structure. It serves as a clinical standard for dental cementation.

Clinical Evidence

No clinical data provided; substantial equivalence is based on the device's long-standing historical use as a standard dental cement.

Technological Characteristics

Two-part system: powder (zinc oxide, magnesium oxide) and liquid (phosphoric acid, distilled water, alumina hydrate, zinc oxide). Non-adhesive luting agent. No electronic or software components.

Indications for Use

Indicated for the cementation of indirect dental restorations and appliances, including inlays, crowns, bridges, facings, and orthodontic brackets.

Regulatory Classification

Identification

Zinc oxide-eugenol is a device composed of zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp. Dental cement other than zinc oxide-eugenol is a device composed of various materials other than zinc oxide-eugenol intended to serve as a temporary tooth filling or as a base cement to affix a temporary tooth filling, to affix dental devices such as crowns or bridges, or to be applied to a tooth to protect the tooth pulp.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/2 description: The image contains a combination of abstract shapes and text. On the left side, there is a stylized, dark shape that resembles a flourish or decorative element. To the right, there is a horizontal line, and below that, there is some text, although it is difficult to discern the exact letters or words due to the image quality. OCT 22 1998 Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Debra Olson Official Correspondent Medental International 1246 Clear Creek Road Evergreen, Colorado 80439 Re : K983018 Trade Name: Zinc Phosphate Cement Regulatory Class: II Product Code: EMA August 25, 1998 Dated: Received: August 28, 1998 Dear Ms. Olson: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions The general controls provisions of the Act of the Act. include reguirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions aqainst misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Requlations, Title 21, Parts 800 to 895. ਸ substantially equivalent determination assumes compliance with the Good Manufacturing Practice for Medical Devices: General (GMP) regulation (21 CFR Part 820) and that, through periodic GMP inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations. {1}------------------------------------------------ Page 2 - Ms. Olson This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4692. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638 2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html". Sincerely Timothy A. Ulatowski Director Division of Dental, Infection Control and General Hospital Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## MEDENTAL INTERNATIONAL 1246 Clear Creek Road Evergreen, CO 80439 Establishment # 1723973 14983018 510(k) Number: Unknown Device Name: Zinc Phosphate Cement Indications for Use: Zinc Phosphate is the oldest of the cementation agents and thus the one with the longest track record (introduced in 1878). It serves as a standard by which newer systems can be compared. It consists of powder and liguid in two separate bottles. The main ingredients of the powder are zinc oxide and magnesium oxide. The liquid contains phosphoric acid, distilled water, alumina hydrate, and zinc oxide. Zinc phosphate cement is without any adhesive properties and is used as a luting agent. It is always referred to as a cement and is used for the attachment of indirect restorations and appliances to the teeth and for the cementation of inlays, crowns, bridges, facings, and orthodontic brackets. Yewed Sheppon (Division Sign Off) (Division Sign-Off) Division of Dental, Infection Control, and General Hospital Devices K943018 510(k) Number.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...