HERADOR EC, PF, C, H, NH, G, GG AND MP; HERALOY U AND G; HERABOND N; ALBABOND C, B AND A; BIO HERANORM
Applicant
Heraeus Kulzer,GmbH
Product Code
EJT · Dental
Decision Date
Mar 1, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3060
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
Reconstruction of porcelain to metal dental restorations/reconstruction of dental restorations.
Device Story
Device consists of a line of gold-based and precious metal alloys used in dental laboratories for the fabrication of dental restorations. These alloys serve as the metallic substructure for porcelain-fused-to-metal (PFM) crowns, bridges, and other dental prosthetics. Dental technicians cast these alloys into the desired shape to provide structural support for porcelain veneers. The resulting restorations are placed by dentists to restore patient tooth function and aesthetics. The alloys provide biocompatible, durable frameworks for dental prostheses.
Clinical Evidence
No clinical data provided; substantial equivalence is based on material composition and physical property testing typical for dental casting alloys.
Technological Characteristics
Gold-based and precious metal alloys. Materials include various combinations of gold, platinum, palladium, and other precious metals. Form factor is casting alloy ingots/pellets. Intended for dental laboratory fabrication of prosthetic substructures. Class II medical device.
Indications for Use
Indicated for the reconstruction of porcelain to metal dental restorations or general dental restorations.
Regulatory Classification
Identification
A noble metal alloy is a device composed primarily of noble metals, such as gold, palladium, platinum, or silver, that is intended for use in the fabrication of cast or porcelain-fused-to-metal crown and bridge restorations.
Special Controls
*Classification.* Class II (special controls). The special control for these devices is FDA's “Class II Special Controls Guidance Document: Dental Noble Metal Alloys.” The devices are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9. See § 872.1(e) for availability of guidance information.
Related Devices
K041433 — BRIGHT GOLD XH · Ivoclar Vivadent, Inc. · Aug 19, 2004
K033446 — APEX93, APEX87, APEX84, APEX85, APEX77, E-SARANG 88 AND E-SARANG 82 · We Dong Myung Dental Industrial Co., Ltd. · Nov 13, 2003
K981002 — ORION WX DENTAL ALLOY · European Dental Imports, Inc. · May 18, 1998
K030436 — BIO UNIVERSAL · Ivoclar Vivadent, Inc. · Apr 15, 2003
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the seal of the Department of Health & Human Services (HHS) of the United States. The seal features a circular design with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is an abstract symbol resembling three stylized waves or stripes, which is a common element in the HHS seal.
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
MAR = 1 2004
Heraeus Kulzer GmbH & Company KG C/O Ms. Cheryl V. Zimmerman Manager, Quality Operations and Compliance Heraeus Kulzer, Incorporated 4315 South Lafayette Boulevard South Bend, Indiana 46614
Re: K034049
KU34049
Trade/Device Names: Herador EC, Herador PF, Herador H, Herador NH, Herador G, Heralor d N Herador GG, Herador MP, Heraloy U, Heraloy G, Herabond N, Albabond C, Albabond B, Albabond A, Bio Heranorm, Mainbond KF, Albabold C, Firsterer KF, Alba KF, Maingold SG, Maingold MP, Kelainingold FRF, Horagold TK, Maingold G, Maingold GV, Bio Maingold IT, Bio Maingold I, Hera SG, Hera PF, and Alba SG Regulation Number: 21 CFR 872.3060 Regulation Name: Gold Based Alloys and Precious Metal Alloys for Clinical Use Regulatory Class: II Product Code: EJT and EJS Dated: December 18, 2003
Received: January 08, 2004
Dear Ms. Zimmerman:
We have reviewed your Section 510(k) premarket notification of intent to market the device We have revewed your section 510(x) premained is substantially equivalent (for the indications for referenced above and have decemined the ac-rices marketed in interstate comments on to devices that use stated in the enclosure) to regally manufacture . Amedical Device American . Or to devices that prior to May 26, 1970, the enactions and of the Federal Food, Drug, and Cosmetic
have been reclassified in accordance with the provisions of the stime (DMA). You may have been reclassified in accordance with the provision (PMA). You may.
Act (Act) that do not require approval of a premarket approval application Act. The separa Act (Act) that do not require approval or a provisions of the Act . The ect. The general therefore, market the device, subject to the general voir annual registration, listing of devices, good
controls provisions of the Act include requirements for and adultarsti controls provisions of the nerade requibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it If your device is classified (Sec above) into Existing major regulations affecting your device can be may be subject to such additions, Title 21, Parts 800 to 898 In addition, FDA may publish found in the Oode of I concerning your device in the Federal Register.
{1}------------------------------------------------
## Page 2 – Ms. Cheryl V. Zimmerman
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4613. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97) you may obtain. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely vours.
Clus
Chiu S. Lin. PhD Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
Page 1 of 1
11 - 11 -
## 1634049 510(k) Number (if Known):
Device Name:
Herador EC Mainbond KF Keramikgold PKF Herador PF Hera KF Herador C Alba KF Herador H Herador NH Maingold SG Maingold MP Herador G Maingold OG Herador GG Bio Maingold TK Herador MP Maingold G Heraloy U Heraloy G Maingold GV Bio Maingold IT Herabond N Bio Maingold I Albabond C Hera SG Albabond B Hera PF Albabond A Alba SG Bio Heranorm
Indications For Use:
Reconstruction of porcelain to metal dental restorations/reconstruction of dental restorations.
## (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
| Concurrence of CDRH, Office of Device evaluation (ODE) | |
|------------------------------------------------------------------------------------|----------------------|
| <div><img alt="Signature" src="signature.png"/></div> | |
| (Division Sign-Off) | |
| Division of Anesthesiology, General Hospital,<br>Infection Control, Dental Devices | |
| 510(k) Number: | X034049 |
| Prescription Use<br>(Per 21 CFR 801.109) | X |
| OR | Over-The-Counter Use |
(Optional Format 1-2-96)
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.