K241673 · Shenzhen Piocreat 3D Technology Co., Ltd. · EBF · Oct 15, 2024 · Dental
Device Facts
Record ID
K241673
Device Name
Denture Base Resin (PN-Denture (Red, White))
Applicant
Shenzhen Piocreat 3D Technology Co., Ltd.
Product Code
EBF · Dental
Decision Date
Oct 15, 2024
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 872.3690
Device Class
Class 2
Indications for Use
Denture Base Resin is a light-curable resin indicated for the fabrication of: ·individual and fixed permanent full single crowns, permanent partial crowns in front and posterior area ·denture bases Denture Base Resin is intended exclusively for professional dental work.
Device Story
Light-curable resin for dental appliance fabrication; used with PioNext D Series 3D printers utilizing Digital Light Processing (DLP) and 405nm UV LED curing. Workflow: CAD/CAM system design; 3D printing; post-curing in PioNext UV-02 chamber; final adjustment by dental professional. Output: permanent crowns and denture bases. Benefits: alternative to traditional heat-cured/auto-polymerization resins; enables precise, customized dental restorations.
Clinical Evidence
No clinical data. Bench testing only. Performance tests included dimensional stability, color stability, translucency, flexural strength, flexural modulus, freedom from porosity, water solubility, and cleaning/disinfection tolerance verification.
Technological Characteristics
Light-curable resin; DLP 3D printing technology; 405nm UV LED curing. Complies with ISO 10477, ISO 20795, ISO 7491, and ISO 4049. Workflow involves CAD/CAM integration.
Indications for Use
Indicated for professional dental fabrication of individual and fixed permanent full single crowns, permanent partial crowns (front and posterior), and denture bases.
Regulatory Classification
Identification
Tooth shade resin material is a device composed of materials such as bisphenol-A glycidyl methacrylate (Bis-GMA) intended to restore carious lesions or structural defects in teeth.
K253324 — UltraPrint-Dental Denture UV · Guangzhou Heygears IMC., Inc. · Nov 20, 2025
K222623 — Digital Crown · Sprintray, Inc. · Dec 14, 2022
K203641 — E-Denture Pro · Envisiontec GmbH · Mar 30, 2021
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/0 description: The image shows the logo of the U.S. Food and Drug Administration (FDA). The logo consists of two parts: the Department of Health & Human Services logo on the left and the FDA logo on the right. The FDA logo is in blue and includes the letters "FDA" followed by the words "U.S. Food & Drug Administration".
October 15, 2024
Shenzhen Piocreat 3D Technology Co., Ltd. % Youshan Gong RA Specialist Feiying Drug & Medical Consulting Technical Service Group Rm 2401 Zhenye International Business Center, No. 3101-90, Oianhai Road Shenzhen, Guangdong 518052 CHINA
Re: K241673
Trade/Device Name: Denture Base Resin (PN-Denture (Red, White)) Regulation Number: 21 CFR 872.3690 Regulation Name: Tooth Shade Resin Material Regulatory Class: Class II Product Code: EBF, EBG, PZY, ELM, EBI Dated: September 19, 2024 Received: September 19, 2024
Dear Youshan Gong:
We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download).
Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30. Design controls; 21 CFR 820.90. Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181).
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050.
All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-device-advicecomprehensive-regulatory-assistance/unique-device-identification-system-udi-system.
Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems.
For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatory
{2}------------------------------------------------
assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100).
Sincerely,
# Michael E. Adjodha -S
Michael E. Adjodha, MChE, RAC, CQIA Assistant Director DHT1B: Division of Dental and ENT Devices OHT1: Office of Ophthalmic, Anesthesia, Respiratory, ENT, and Dental Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
### Indications for Use
Submission Number (if known)
K241673
Device Name
Denture Base Resin (PN-Denture (Red, White))
Indications for Use (Describe)
Denture Base Resin is a light-curable resin indicated for the fabrication of: ·individual and fixed permanent full single crowns, permanent partial crowns in front and posterior area
·denture bases
Denture Base Resin is intended exclusively for professional dental work.
Type of Use (Select one or both, as applicable)
Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{4}------------------------------------------------
| 510(k) #: K241673 | | 510(k) Summary | | Prepared on: 2024-09-20 |
|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------|-----------------------------------------------------------------------------------|--|-------------------------|
| Contact Details | | | | 21 CFR 807.92(a)(1) |
| Applicant Name | | Shenzhen Piocreat 3D Technology Co., Ltd. | | |
| Applicant Address | | Rm 1308 Bldg 3, Jincheng Ind Park,Longhua Dist Shenzhen Guangdong<br>518109 China | | |
| Applicant Contact Telephone | | +86-13349894887 | | |
| Applicant Contact | | Mr. Jason Cai | | |
| Applicant Contact Email | | jasonwales@163.com | | |
| Device Name | | | | 21 CFR 807.92(a)(2) |
| Device Trade Name | | Denture Base Resin (PN-Denture (Red, White)) | | |
| Common Name | | Tooth shade resin material | | |
| Classification Name | | Material, Tooth Shade, Resin | | |
| Regulation Number | | 872.3690 | | |
| Product Code(s) | | EBF, EBI, EBG, PZY, ELM | | |
| Legally Marketed Predicate Devices | | | | 21 CFR 807.92(a)(3) |
| Predicate # | Predicate Trade Name (Primary Predicate is listed first) | | | Product Code |
| K210977 | E-Dent 1000 | | | EBF |
| K220771 | Stratasys TrueDent | | | EBF |
| Device Description Summary | | | | 21 CFR 807.92(a)(4) |
| The Denture Base Resin is an alternative to traditional heat cured and auto polymerization resins. The resins are available in two (2)<br>different colors ( white, red). Denture Base Resin can be used with PioNext D Series. PioNext D Series printers include a 3D printing<br>system that utilizes Digital Light Process (DLP) technology, with automatic feeding process, and a UV LED (405nm) curing process. The<br>dental appliance is then cured in the PioNext UV-02 curing chamber and sent back to the dentist for try-in and final adjustment. | | | | |
| Intended Use/Indications for Use | | | | 21 CFR 807.92(a)(5) |
| Denture Base Resin is a light-curable resin indicated for the fabrication of:<br>-individual and fixed permanent full single crowns, permanent partial crowns in front and posterior area<br>•denture bases<br>Denture Base Resin is intended exclusively for professional dental work. | | | | |
| Indications for Use Comparison | | | | 21 CFR 807.92(a)(5) |
| The subject device and predicate devices have the same indications for use. | | | | |
| Though the Indications for Use of subject device is little different from the predicate device, the main difference is that the subject<br>device is indicated for denture bases which is not included in the indications of the primary predicate but is addressed by the reference<br>device. The Indications for Use for both the subject device and primary predicate include statements that the material is an alternative to | | | | |
{5}------------------------------------------------
traditional light-curable resin and is intended exclusively for professional dental work. Both the subject device and primary predicate require fabrication of these devices using a computer aided design and manufacturing (CAD/CAM) system. The subject device Indications for Use Statement does not list the process components, as it is not necessary that such components be listed in the Statement. Thus, this difference is insignificant and do not raise any safety or effectiveness problems.
## Technological Comparison
### 21 CFR 807.92(a)(6)
The subject device and predicate devices have the same technological characteristics, the subject device conduct performance test, it can comply with ISO 10477, and ISO 20795, ISO 7491, ISO 4049, guidance "Denture Base Resins - Performance Criteria for Safety and Performance Based Pathway: Guidance for Industry and Food and Drug Administration Staff".
The technological characteristics such as mechanical aroperties, printing technology, chemical description, material type, cutting method, product state, product characteristics, and workflow are similar to the predicate device. Any minor differences between the subject device and the listed predicate device do no raise any issues of safety or efficacy. Performance data supports that the device is safe and as effective as the predicate device for its intended use.
# Non-Clinical and/or Clinical Tests Summary & Conclusions 21 CFR 807.92(b)
Non-clinical: We conducted the Denture Base Resin Performance test, including Woimensional stability, Molor and color stability, ITranslucency, Wexural strength and flexural modulus, Mreedom from porosity, Mater Solublity, and we also conducted the Verification Report of Cleaning and Disinfection Tolerance. The subject device can meet the requirements.
Clinical test: Not Applicable.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.