IMZ TWIN PLUS SCREW
Device Facts
| Record ID | K963520 |
|---|---|
| Device Name | IMZ TWIN PLUS SCREW |
| Applicant | Imz, GmbH |
| Product Code | DZE · Dental |
| Decision Date | Aug 12, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 872.3640 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
IMZ implants are indicated for single tooth replacement, as immediate abutments on long span to bridgework, as distal abutments on free-end edentulous areas to be restored with fixed bridgework, to support overdentures in totally or partially edentulous arches, and as abutments supporting a full arch fixed prosthesis in the totally edentulous mandible or maxila.
Device Story
IMZ Twin Plus Screw is a dental implant system used for prosthetic restoration. Device serves as an artificial root/abutment to support single crowns, fixed bridges, or overdentures. Used by dental surgeons/clinicians in clinical settings to restore function and aesthetics in edentulous or partially edentulous patients. System integrates into jawbone to provide stable foundation for dental prosthetics. Benefits include improved masticatory function and oral rehabilitation.
Clinical Evidence
bench testing only
Technological Characteristics
Dental implant system; screw-type design; intended for osseointegration in mandibular or maxillary bone. Specific materials and ASTM standards not detailed in provided text.
Indications for Use
Indicated for patients requiring dental restoration, including single tooth replacement, fixed bridgework (long span or distal abutments), and overdentures or full arch fixed prostheses in totally or partially edentulous mandibular or maxillary arches.
Regulatory Classification
Identification
An endosseous dental implant is a prescription device made of a material such as titanium or titanium alloy that is intended to be surgically placed in the bone of the upper or lower jaw arches to provide support for prosthetic devices, such as artificial teeth, in order to restore a patient's chewing function.
Special Controls
*Classification.* (1) Class II (special controls). The device is classified as class II if it is a root-form endosseous dental implant. The root-form endosseous dental implant is characterized by four geometrically distinct types: Basket, screw, solid cylinder, and hollow cylinder. The guidance document entitled “Class II Special Controls Guidance Document: Root-Form Endosseous Dental Implants and Endosseous Dental Implant Abutments” will serve as the special control. (See § 872.1(e) for the availability of this guidance document.)(2) *Classification.* Class II (special controls). The device is classified as class II if it is a blade-form endosseous dental implant. The special controls for this device are:(i) The design characteristics of the device must ensure that the geometry and material composition are consistent with the intended use; (ii) Mechanical performance (fatigue) testing under simulated physiological conditions to demonstrate maximum load (endurance limit) when the device is subjected to compressive and shear loads; (iii) Corrosion testing under simulated physiological conditions to demonstrate corrosion potential of each metal or alloy, couple potential for an assembled dissimilar metal implant system, and corrosion rate for an assembled dissimilar metal implant system; (iv) The device must be demonstrated to be biocompatible; (v) Sterility testing must demonstrate the sterility of the device; (vi) Performance testing to evaluate the compatibility of the device in a magnetic resonance (MR) environment; (vii) Labeling must include a clear description of the technological features, how the device should be used in patients, detailed surgical protocol and restoration procedures, relevant precautions and warnings based on the clinical use of the device, and qualifications and training requirements for device users including technicians and clinicians; (viii) Patient labeling must contain a description of how the device works, how the device is placed, how the patient needs to care for the implant, possible adverse events and how to report any complications; and (ix) Documented clinical experience must demonstrate safe and effective use and capture any adverse events observed during clinical use.
Related Devices
- K963521 — IMZ TWIN PLUS - CYLINDER · Imz, GmbH · Aug 6, 1997
- K053478 — ENDOSSEOUS DENTAL IMPLANT SYSTEM · Northern Implants, LLC · Apr 5, 2006
- K162004 — PREMIUM Implant Systems SHELTA Implant Systems · Sweden & Martina S.P.A. · Dec 5, 2016
- K022425 — SCREWLINE · Altatec Biotechnologies N.A., Inc. · Aug 14, 2002
- K973049 — IMCOR EXTERNALLY HEXED, SELF-TAPPING SCREW IMPLANT SURGICAL DRILLING SYSTEM · Imcor · Nov 13, 1997