INSPEKTOR PRO

K040063 · Inspektor Dental Care BV · NBL · Jun 24, 2004 · Dental

Device Facts

Record IDK040063
Device NameINSPEKTOR PRO
ApplicantInspektor Dental Care BV
Product CodeNBL · Dental
Decision DateJun 24, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.1745
Device ClassClass 2

Intended Use

The Inspektor™ Pro is intended to be used as an aid in the diagnosis of dental caries.

Device Story

Inspektor™ Pro is a dental fluorescence examination system used by dental professionals in clinical settings. The system comprises a handpiece, systembox, computer, monitor, and footswitch. It utilizes fluorescence technology to detect dental caries; the device captures optical signals from the tooth surface, which are processed by the integrated computer system to provide visual or quantitative feedback to the clinician. This output assists the dentist in identifying carious lesions, facilitating clinical decision-making regarding treatment. The device is intended to improve diagnostic accuracy for dental caries.

Technological Characteristics

System includes a handpiece, systembox, computer, monitor, mouse, keyboard, and footswitch. Operates via fluorescence detection of dental caries. Class II device (Product Code: NBL).

Indications for Use

Indicated for use as an aid in the diagnosis of dental caries in patients requiring dental examination.

Regulatory Classification

Identification

A laser fluorescence caries detection device is a laser, a fluorescence detector housed in a dental handpiece, and a control console that performs device calibration, as well as variable tone emitting and fluorescence measurement functions. The intended use of the device is to aid in the detection of tooth decay by measuring increased laser induced fluorescence.

Special Controls

*Classification.* Class II, subject to the following special controls:(1) Sale, distribution, and use of this device are restricted to prescription use in accordance with § 801.109 of this chapter; (2) Premarket notifications must include clinical studies, or other relevant information, that demonstrates that the device aids in the detection of tooth decay by measuring increased laser induced fluorescence; and (3) The labeling must include detailed use instructions with precautions that urge users to: (i) Read and understand all directions before using the device, (ii) Store probe tips under proper conditions, (iii) Properly sterilize the emitter-detector handpick before each use, and (iv) Properly maintain and handle the instrument in the specified manner and condition.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ JUN 2 4 2004 Image /page/0/Picture/1 description: The image shows the logo for Inspektor Dental Care. The logo consists of a right-pointing arrow followed by the word "INSPEKTOR" in bold, sans-serif font. Below "INSPEKTOR" is the phrase "DENTAL CARE" in a smaller, sans-serif font. The arrow is a simple line drawing with a triangular head. K040063 Head Office Pieter Baststraat 21-27 1071 TV Amsterdam The Netherlands T. +31 20-470 1512 F. +31 84 884 1199 E. idc@inspektordentalcare.com #### Development & production Quellijnstraat 92 1072 XX Amsterdam T. +31 20 676 4988 F. +31 20 679 3183 # 510(k) Summary # 4.1. Applicant | Name | Inspektor Dental Care bv | | |---------------------|-----------------------------|--| | Address | (Head office) | | | | Pieter Baststraat 21-27 | | | | 1071 TV Amsterdam | | | Telephone | +31 20 470 1512 | | | Fax | +31 20 679 3183 | | | e-mail | idc@inspektordentalcare.com | | | Establishment | | | | Registration number | not available | | | Contact Person | Elbert Waller | | | Address | Inspektor Dental Care bv | | | | (Development & Production) | | | | Quellijnstraat 92 | | | | 1072 XX Amsterdam | | | | Netherlands | | | Telephone | +31 20 676 4988 | | | Fax | +31 20 679 3183 | | | e-mail | c.waller@inspektor.nl | | ## 4.2. Date summary prepared June 17, 2004 c-mail ## 4.3. Name of the Device : Inspektor™ Pro Proprietary/trade name : Dental Fluorescence Examination Device Common name : K040064 510(k) Number 4.4. Predicate Devices: KaVo DIAGNOdent, K983658 ## 4.5. Device description The Inspektor™ Pro consists of a systembox equipped with a handpiece, mounted in a\trolley together with a computer, a monitor, mouse, keyboard and footswitch. Chamber of commerce Amsterdam 341 92 359 Van Lanschot banking 63.25.62.95 VAT NL 812 444 231 B01 {1}------------------------------------------------ #### 4.6. Intended Use The Inspektor™ Pro is intended to be used as an aid in the diagnosis of dental caries. #### 4.7. Indications for use The Inspektor™ Pro is indicated as an aid in the diagnosis of dental caries. ### 4.8. Substantial Equivalence Inspektor™ Pro resembles the predicate device DIAGNOdent as an aid in the diagnosis of dental caries. I hereby declare that the information stated in this 510(k) summary is truthful and accurate. Date June 17, 2004 Place Amsterdam Signature: Elbert Waller Elbert V er (CDO Inspektor Dental Čare BV) {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES • USA" around the perimeter. Inside the circle is an abstract symbol resembling an eagle or bird in flight, composed of three curved lines representing wings and a stylized tail. #### Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUN 2 4 2004 Inspektor Dental Care BV Mr. Elbert Waller (Development & Production) Quellijnstraat 92 1072 XX Amsterdam NETHERLANDS Re: K040063 Trade/Device Name: Inspektor™ Pro Regulation Number: 872.1745 Regulation Name: Laser Fluorescence Caries Detection Device Regulatory Class: II Product Code: NBL Dated: April 8, 2004 Received: April 13, 2004 Dear Mr. Waller: We have reviewed your Section 510(k) premarket notification of intent to market the device we have rother and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Interstate conments of press that have been reclassified in accordance with the provisions of Amendinens, or to do roug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general approvin apprevisions of the Act. The general controls provisions of the Act include controls provisions or al registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting (1 Mr), it may of each be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In your device early of ther announcements concerning your device in the Federal Register. {3}------------------------------------------------ Page 2 - Mr. Waller Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements mount that I Dr may Federal statutes and regulations administered by other Federal agencies. or the rice of all , outh all the Act's requirements, including, but not limited to: registration 1 od into comply with 807); labeling (21 CFR Part 801); good manufacturing practice and listing (21 CF read vir the quality systems (QS) regulation (21 CFR Part 820); and if requirements as the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) This letter will and A yourse of substantial equivalence of your device to a premarket notification - I s device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4618. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the may obtain other gManufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Ques Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # INDICATION FOR USE STATEMENT 510(k) Number: K040063 Device Name: Inspektor™ Pro Indications for use: The Inspektor™ Pro is indicated as an aid in the diagnosis of dental caries. # (PLEASE DO NOT WRITE BELOW THIS LINE -- CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDHR, Office of Device Evaluation (ODE) | Prescription use | X | OR (Per 21 CFR 801.109) | Over-The-Counter Use _____ | |------------------|---|-------------------------|----------------------------| |------------------|---|-------------------------|----------------------------| (Optional format 1-2-9) | | <center>(Division Sign-Off)</center> Division of Anesthesiology, General Hospital, Infection Control, Dental Devices | |--|----------------------------------------------------------------------------------------------------------------------------------| |--|----------------------------------------------------------------------------------------------------------------------------------| | 1602.510kAIR.02-02.doc | 510(k) Number: R040063 | 2-1 | |------------------------|------------------------|-----| |------------------------|------------------------|-----|