We're working on improving this tool, so please
email us
suggestions.
Sign up
for email updates to learn about new features.
✕
FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Diagnostic Devices
CFR Sub-Part
General Hospital and Personal Use Miscellaneous Devices
CFR Sub-Part
Miscellaneous
Miscellaneous
Miscellaneous Devices
CFR Sub-Part
Physical Medicine Diagnostic Devices
CFR Sub-Part
Physical Medicine Prosthetic Devices
CFR Sub-Part
Physical Medicine Therapeutic Devices
CFR Sub-Part
Prosthetic Devices
CFR Sub-Part
DZS
Capsule, Dental, Amalgam
1
Product Code
DYH
Adhesive, Bracket And Tooth Conditioner, Resin
2
Product Code
DZE
Implant, Endosseous, Root-Form
2
Product Code
EBC
Sealant, Pit And Fissure, And Conditioner
2
Product Code
EBD
Coating, Filling Material, Resin
2
Product Code
EBE
Coating, Denture Hydrophilic, Resin
2
Product Code
EBF
Material, Tooth Shade, Resin
2
Product Code
EBG
Crown And Bridge, Temporary, Resin
2
Product Code
EBH
Material, Impression Tray, Resin
1
Product Code
EBI
Resin, Denture, Relining, Repairing, Rebasing
2
Product Code
EBL
Pin, Retentive And Splinting, And Accessory Instruments
1
Product Code
EBO
Denture Repair Kit
2
Product Code
EBP
Reliner, Denture, Over The Counter
2
Product Code
EFD
Amalgamator, Dental, Ac-Powered
1
Product Code
EFT
Cleanser, Denture, Over The Counter
1
Product Code
EGG
Attachment, Precision, All
1
Product Code
EHE
Dispenser, Mercury And/Or Alloy
1
Product Code
EHO
Bar, Preformed
1
Product Code
EHP
Clasp, Preformed
1
Product Code
EHQ
Cusp, Preformed
1
Product Code
EHR
Pad, Denture, Over The Counter
2
Product Code
EHS
Cushion, Denture, Over The Counter
2
Product Code
EIT
Applicator, Rapid Wax, Dental
2
Product Code
EJH
Alloy, Metal, Base
2
Product Code
EJJ
Alloy, Amalgam
2
Product Code
EJK
Liner, Cavity, Calcium Hydroxide
2
Product Code
EJL
Bur, Dental
1
Product Code
EJP
Articulators
1
Product Code
EJS
Alloy, Other Noble Metal
2
Product Code
EJT
Alloy, Gold-Based Noble Metal
2
Product Code
EJW
Clasp, Wire
1
Product Code
EJX
Anchor, Preformed
1
Product Code
EKL
Point, Silver, Endodontic
1
Product Code
EKM
Gutta-Percha
1
Product Code
EKN
Point, Paper, Endodontic
1
Product Code
EKO
Denture Preformed (Partially Prefabricated Denture)
2
Product Code
ELE
Implant, Subperiosteal
2
Product Code
ELJ
Teeth, Artificial, Posterior With Metal Insert
1
Product Code
ELK
Teeth, Artificial, Backing And Facing
1
Product Code
ELL
Teeth, Porcelain
2
Product Code
ELM
Denture, Plastic, Teeth
2
Product Code
ELN
Teeth, Preformed Gold Denture
1
Product Code
ELO
Cusp, Gold And Stainless Steel
1
Product Code
ELR
Post, Root Canal
1
Product Code
ELS
Splint, Endodontic Stabilizing
2
Product Code
ELW
Material, Impression
2
Product Code
ELY
Mercury
2
Product Code
ELZ
Crown, Preformed
1
Product Code
EMA
Cement, Dental
2
Product Code
EMB
Zinc Oxide Eugenol
1
Product Code
JER
Cleaner, Denture, Mechanical
1
Product Code
KCR
Facebow
1
Product Code
KCS
Pantograph
1
Product Code
KIF
Resin, Root Canal Filling
2
Product Code
KLE
Agent, Tooth Bonding, Resin
2
Product Code
KOL
Adhesive, Denture, Carboxymethylcellulose Sodium (32%) And Ethylene-Oxide Homopolymer
1
Product Code
KOM
Adhesive, Denture, Acacia And Karaya With Sodium Borate
1
Product Code
KON
Adhesive, Denture, Polyacrylamide Polymer (Modified Cationic)
3
Product Code
KOO
Adhesive, Denture, Polyvinyl Methylether Maleic Acid Calcium-Sodium Double Salt
1
Product Code
KOP
Adhesive, Denture, Karaya
1
Product Code
KOQ
Adhesive, Denture, Carboxymethylcellulose Sodium (40-100&)
1
Product Code
KOR
Adhesive, Denture, Karaya With Sodium Borate
3
Product Code
KOS
Adhesive, Denture, Carboxymethylcellulose Sodium And Cationic Polyacrylamide Polymer
3
Product Code
KOT
Carboxymethylcellulose Sodium Or Polyvinyl Methylether Maleic Acid Calcium-Sodium
1
Product Code
KXR
Applicator, Resin
1
Product Code
KXW
Adhesive, Denture, Carboxymethylcellulose Sodium (49%) And Ethylene-Oxide Homopolymer
1
Product Code
KXX
Adhesive, Denture, Karaya And Ethylene-Oxide Homopolymer
1
Product Code
KXY
Polyvinyl Methylether Maleic Anhydride &/Or Acid Copolymer & Carboxymethylce
3
Product Code
KZN
Scanner, Color
2
Product Code
KZO
Ink, Arch Tracing
1
Product Code
KZP
Solution, Cement Dissolving
2
Product Code
LBH
Varnish, Cavity
2
Product Code
LPK
Bone Grafting Material, For Dental Bone Repair
2
Product Code
LYC
Bone Grafting Material, Synthetic
2
Product Code
LZD
Joint, Temporomandibular, Implant
3
Product Code
MMT
Resin, Root Canal Filling Containing Chloroform
3
Product Code
MMU
Adhesive, Denture, Acacia And Karaya With Sodium Borate > 12% By Weight
3
Product Code
MPI
Glenoid Fossa Prosthesis
3
Product Code
MPJ
Interarticular Disc Prosthesis (Interpositional Implant)
3
Product Code
MPL
Mandibular Condyle Prosthesis
3
Product Code
MZW
Dental Cement W/Out Zinc-Oxide Eugenol As An Ulcer Covering For Pain Relief
2
Product Code
NDP
Accessories, Implant, Dental, Endosseous
1
Product Code
NFE
Materials, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Alveolar Ridge Augmentation
2
Product Code
NHA
Abutment, Implant, Dental, Endosseous
2
Product Code
K
21
1396
Neoss Individual Prosthetics
2
Cleared 510(K)
K
22
0252
High Retention Attachment System
2
Cleared 510(K)
K
21
3063
TLX SRAs and TLX Gold Abutments
2
Cleared 510(K)
K
21
3432
MIS Angulated multi-unit abutments
2
Cleared 510(K)
K
21
2628
DESS Dental Smart Solutions
2
Cleared 510(K)
K
21
2676
Osteon Precision Milled Suprastructure
2
Cleared 510(K)
K
21
0356
Noris Medical Dental Implants System
2
Cleared 510(K)
K
21
0826
Healing Abutment, Cover Screw
2
Cleared 510(K)
K
20
1323
INNO SLA Submerged Implant System
2
Cleared 510(K)
K
21
3391
High Retention Attachment System
2
Cleared 510(K)
K
21
2730
BellaTek Encode Emergence Healing Abutments
2
Cleared 510(K)
K
21
2577
DESS Dental Smart Solutions
2
Cleared 510(K)
K
21
2664
Sherlock
2
Cleared 510(K)
K
21
1871
FAICO Dental Implant System and CAD/CAM Abutments
2
Cleared 510(K)
K
21
3449
DS Implants abutments provided with the EV connection
2
Cleared 510(K)
K
20
3808
Multi-unit Abutment, Multi-unit Angled Abutment
2
Cleared 510(K)
K
20
3750
Straumann CARES P-Series CAD/CAM System
2
Cleared 510(K)
K
21
2108
Dynamic TiBase
2
Cleared 510(K)
K
20
3649
TruAbutment DS, TruBase
2
Cleared 510(K)
K
21
0410
s-Clean Pre-Milled Abutment Mini
2
Cleared 510(K)
K
20
3344
Premilled Titanium Block System
2
Cleared 510(K)
K
21
0362
s-Clean Pre-Milled Abutment
2
Cleared 510(K)
K
20
0193
Kisses Plus Implant System
2
Cleared 510(K)
K
20
3464
DESS Dental Smart Solutions
2
Cleared 510(K)
K
20
3542
Neodent Implant System - Mini Abutment 60°
2
Cleared 510(K)
K
21
1225
MIS Ti-base abutment
2
Cleared 510(K)
K
21
0903
IS Multi Unit Abutment System
2
Cleared 510(K)
K
20
2579
TruAbutment DS, TruBase
2
Cleared 510(K)
K
20
3456
Straumann CARES M-Series CAD/CAM System
2
Cleared 510(K)
K
20
1842
TruBase S
2
Cleared 510(K)
K
20
3240
AccelX Abutments
2
Cleared 510(K)
K
20
2909
CreoDent Solidex Customized Abutment
2
Cleared 510(K)
K
20
1197
TruAbutment DS, TruBase S
2
Cleared 510(K)
K
20
1681
Straumann Immediate Temporary Abutments
2
Cleared 510(K)
K
20
3252
Multi-unit Abutments for CONELOG
2
Cleared 510(K)
K
20
1860
Elos Accurate Hybrid Base
2
Cleared 510(K)
K
20
3355
Straumann TLX Novaloc and Cementable Abutments
2
Cleared 510(K)
K
19
2742
Straumann Variobase C
2
Cleared 510(K)
K
20
2282
Neodent Implant System - Zirconia Implant System
2
Cleared 510(K)
K
20
2026
Blue Sky Bio CAD-CAM Abutments
2
Cleared 510(K)
K
20
2095
CreoDent Solidex Customized Abutment and Screw
2
Cleared 510(K)
K
20
1711
CARES Screw - Retained Bars and Bridges (SRBB)
2
Cleared 510(K)
K
20
2452
NobelProcera Zirconia Implant Bridge
2
Cleared 510(K)
K
20
2418
Magic UCLA Abutment System
2
Cleared 510(K)
K
20
2269
PRE-MILLED Abutment
2
Cleared 510(K)
K
19
3193
Telio CAD Abutment Solutions- extra systems
2
Cleared 510(K)
K
19
3084
TIB Abutment System
2
Cleared 510(K)
K
20
0827
LOCATOR R-Tx
2
Cleared 510(K)
K
20
0597
Straumann BLX Gold Abutments
2
Cleared 510(K)
K
19
3408
Sirona Dental CAD/CAM System with CEREC Chairside Software
2
Cleared 510(K)
K
19
3046
Straumann® Retentive System – Novaloc TiN Abutments
2
Cleared 510(K)
K
20
0355
Duranext Abutments
2
Cleared 510(K)
K
20
1621
Magicore II System
2
Cleared 510(K)
K
19
1152
MIS Ti-base Abutment
2
Cleared 510(K)
K
19
1913
TruAbutment DS
2
Cleared 510(K)
K
20
0753
IBS Implant System II
2
Cleared 510(K)
K
19
3404
UF(II) Bar holder abutment
2
Cleared 510(K)
K
19
2218
Custom Legacy and Custom InterActive Titanium Abutments
2
Cleared 510(K)
K
19
2108
Panthera Dental Milled Bars
2
Cleared 510(K)
K
19
2401
Straumann Screw-Retained Abutments
2
Cleared 510(K)
K
20
0040
Universal Base Conical Connection (CC)
2
Cleared 510(K)
K
19
3078
MIS CONNECT Conical Connection System
2
Cleared 510(K)
K
19
3335
Sherlock
2
Cleared 510(K)
K
19
3425
Pre-Milled Blank
2
Cleared 510(K)
K
19
3529
ATLANTIS Abutment for MIS Conical Connection Implants
2
Cleared 510(K)
K
19
3064
Atlantis suprastructures
2
Cleared 510(K)
K
19
3274
Rodo Abutment System
2
Cleared 510(K)
K
20
0189
Luna Dental Implant System- Healing Abutment
2
Cleared 510(K)
K
19
2263
UCLA CCM Abutment
2
Cleared 510(K)
K
19
2614
Meg-Ball Attachment System, Meg-Loc Abutment, Meg-Magnet Abutment
2
Cleared 510(K)
K
19
1919
Elos Accurate Hybrid Base
2
Cleared 510(K)
K
19
1890
Elos Accurate Customized Abutment
2
Cleared 510(K)
K
18
3106
TruAbutment DS
2
Cleared 510(K)
K
19
2436
Healing Abutments and Cover Screws
2
Cleared 510(K)
K
19
1123
Multi-unit Abutments
2
Cleared 510(K)
K
19
2893
Straumann Ceramic Healing Abutments
2
Cleared 510(K)
K
19
2457
Elos Accurate Customized Abutment
2
Cleared 510(K)
K
19
2229
Neodent Implant System- GM Titanium Base for Bridge
2
Cleared 510(K)
K
19
2522
TSV BellaTek Express and BellaTek Flex Abutments
2
Cleared 510(K)
K
19
1250
Southern Implants PEEK Abutments
2
Cleared 510(K)
K
19
1191
Neodent Implant System - Temporary Abutments
2
Cleared 510(K)
K
19
1986
DESS Dental Smart Solutions
2
Cleared 510(K)
K
19
1634
Scan Abutments and Comfort Caps
2
Cleared 510(K)
K
19
2029
Straumann PUREloc abutments
2
Cleared 510(K)
K
19
1458
Legacy SMARTBase Abutments
2
Cleared 510(K)
K
19
0048
UF(II) Anatomic abutment
2
Cleared 510(K)
K
19
1382
IPS e.max CAD Abutment Solutions- extra systems
2
Cleared 510(K)
K
19
0491
Blue Sky Bio Zygomatic Implant System
2
Cleared 510(K)
K
19
1222
Inclusive Titanium Abutments compatible with: Dentsply Implants Astra Tech Implant System EV
2
Cleared 510(K)
K
18
2455
A.B. DENTAL DEVICES Dental Implants System
2
Cleared 510(K)
K
18
2091
Osstem Abutment System
2
Cleared 510(K)
K
18
3079
Conometric Abutments
2
Cleared 510(K)
K
18
3138
Certain BellaTek Express and BellaTek Flex Abutments
2
Cleared 510(K)
K
19
0654
Straumann CI RD Ceramic Healing Caps
2
Cleared 510(K)
K
19
0299
Elos Accurate® Customized Abutment
2
Cleared 510(K)
K
19
0097
Straumann CARES Screw-Retained Bridges and Bars
2
Cleared 510(K)
K
18
3580
Panthera Dental Milled Bars
2
Cleared 510(K)
K
17
3570
SD Abutment
2
Cleared 510(K)
K
19
0082
Straumann BLX Variobase Abutment
2
Cleared 510(K)
K
18
2246
MIST IC
2
Cleared 510(K)
K
19
0040
Straumann BLX Line Extension - New Abutments
2
Cleared 510(K)
K
18
3518
Preat Abutments
2
Cleared 510(K)
K
18
1580
Cortex CAD/CAM Abutments
2
Cleared 510(K)
K
18
2228
MIS LOCKiT Abutments System, OT-Equators and Ball Attachments
2
Cleared 510(K)
K
18
0564
Medentika Abutment System, Medentika CAD/CAM Abutments, Medentika CAD/CAM TiBases
2
Cleared 510(K)
K
18
1037
DIO CAD/CAM Abutment
2
Cleared 510(K)
K
18
1869
On1 Universal Abutment
2
Cleared 510(K)
K
18
1381
A.B. Dental Devices Dental Implants System
2
Cleared 510(K)
K
18
0184
Zeramex(R) XT Dental Implant System, NobelPearl Dental Implant System
2
Cleared 510(K)
K
18
0899
Universal Base Abutment
2
Cleared 510(K)
K
18
1520
Sirona Dental CAD/CAM System
2
Cleared 510(K)
K
17
3945
Straumann SC Variobase Abutments
2
Cleared 510(K)
K
18
0998
BioHorizons CAD/CAM Bars
2
Cleared 510(K)
K
17
1532
TruBase S
2
Cleared 510(K)
K
18
1359
InterActive SMARTBase Abutments
2
Cleared 510(K)
K
18
1189
ATLANTIS Conus Structure
2
Cleared 510(K)
K
17
3968
Straumann Variobase for Bridge/Bar Cylindrical
2
Cleared 510(K)
K
17
3908
DESS Dental Smart Solutions
2
Cleared 510(K)
K
18
0609
Rodo Smilekey
2
Cleared 510(K)
K
17
2430
ArgenIS Titanium Abutments
2
Cleared 510(K)
K
17
2640
Dentium Implantium & SuperLine Prosthetics
2
Cleared 510(K)
K
16
2021
3.0 Dynamic TiBase
2
Cleared 510(K)
K
17
3902
Neodent Implant System – GM Line
2
Cleared 510(K)
K
17
1409
OT EQUATOR
2
Cleared 510(K)
K
17
3379
Straumann Variobase for Crown AS
2
Cleared 510(K)
K
17
3326
MIS CONNECT Conical Connection Abutment
2
Cleared 510(K)
K
17
3120
CCM Abutment System
2
Cleared 510(K)
K
17
1649
Straumann CARES M-Series CAD/CAM System
2
Cleared 510(K)
K
17
2160
Southern Implants PEEK Abutments
2
Cleared 510(K)
K
16
1989
PREMIUM Implant Systems SHELTA Implant Systems
2
Cleared 510(K)
K
17
3466
Panthera Dental Milled Bars
2
Cleared 510(K)
K
17
2304
TruAbutment DS
2
Cleared 510(K)
K
17
1799
Elos Accurate Customized Abutment, Elos Prosthetic Screw
2
Cleared 510(K)
K
17
1622
Dentium Ti-Base
2
Cleared 510(K)
K
17
0421
ET Hybrid Abutment
2
Cleared 510(K)
K
17
2798
Straumann CARES Abutments CoCr
2
Cleared 510(K)
K
17
2854
NobelPerfect Abutments
2
Cleared 510(K)
K
17
3374
TSV BellaTek Encode Healing Abutments
2
Cleared 510(K)
K
17
1773
Straumann n!ce Glass Ceramic A14 Blocks
2
Cleared 510(K)
K
17
2225
Atlantis Abutment for MIS Implant
2
Cleared 510(K)
K
17
1694
s-Clean TiN Coating Abutments
2
Cleared 510(K)
K
17
1466
NobelDesign, DTX Studio Design
2
Cleared 510(K)
K
17
1757
Straumann Screw Retained Abutments
2
Cleared 510(K)
K
17
0022
Klockner Vega TiBase for CEREC
2
Cleared 510(K)
K
17
0080
Neodent Implant System - CM Pro PEEK Abutment
2
Cleared 510(K)
K
17
1142
Healing Cap Multi-Unit Titanium
2
Cleared 510(K)
K
17
1922
Anatotemp Anatomic Dental Implant Healing Abutment
2
Cleared 510(K)
K
16
2848
Straumann CARES Golden Ti/TiN Abutments
2
Cleared 510(K)
K
17
0013
Eztetic BellaTek Encode Healing Abutments
2
Cleared 510(K)
K
17
0838
Medentika CAD/CAM TiBases
2
Cleared 510(K)
K
17
0384
Dentium NR Line CAD/CAM Abutments
2
Cleared 510(K)
K
16
3398
ATLANTIS suprastructures
2
Cleared 510(K)
K
17
0588
DESS Dental Smart Solutions
2
Cleared 510(K)
K
16
2633
Custom Bars
2
Cleared 510(K)
K
17
0100
CreoDent Solidex Customized Abutment and Screw
2
Cleared 510(K)
K
17
0356
Straumann Variobase Abutments
2
Cleared 510(K)
K
17
0354
Straumann Variobase Abutments
2
Cleared 510(K)
K
17
0044
Inclusive Titanium Abutments compatible with: MegaGen AnyRidge Implant System
2
Cleared 510(K)
K
17
0259
TruAbutment DS
2
Cleared 510(K)
K
16
1689
OSSTEM Implant System - Abutment
2
Cleared 510(K)
K
16
2734
CreoDent Solidex Customized Abutment
2
Cleared 510(K)
K
16
0670
ET US SS Prosthetic system
2
Cleared 510(K)
K
16
3350
Multibase Abutments EV and ATLANTIS Suprastructures
2
Cleared 510(K)
K
16
2028
PREMIUM - SHELTA Prosthetic Components
2
Cleared 510(K)
K
16
1416
Multi-unit Abutment Plus
2
Cleared 510(K)
K
16
1655
On1 Concept
2
Cleared 510(K)
K
16
2390
ET Hybrid Abutment
2
Cleared 510(K)
K
16
1713
Dentium CAD/CAM Abutments
2
Cleared 510(K)
K
16
0798
IPS e.max® Press Abutment Solutions for Viteo Base Ti
2
Cleared 510(K)
K
16
2004
PREMIUM Implant Systems SHELTA Implant Systems
2
Cleared 510(K)
K
15
3015
Transfer & Angled Abutment
2
Cleared 510(K)
K
16
1435
Temporary Snap Abutment
2
Cleared 510(K)
K
16
0786
RODO Abutment System
2
Cleared 510(K)
K
16
0132
Dental Implant Abutment OKTAGON Bone Level RC, Dental Implant Abutment OKTAGON Bone Level NC
2
Cleared 510(K)
K
16
0979
Inclusive Abutments
2
Cleared 510(K)
K
16
0519
Link Abutment for CEREC
2
Cleared 510(K)
K
16
1677
Straumann Sterile Healing Solution
2
Cleared 510(K)
K
16
0436
CreoDent Solidex Custom Abutment
2
Cleared 510(K)
K
16
0207
ATLANTIS ISUS Implant Suprastructures
2
Cleared 510(K)
K
16
0964
Neodent Implant System - Titanium Base for CEREC
2
Cleared 510(K)
K
16
0828
Dentium Implantium & SuperLine Prosthetics
2
Cleared 510(K)
K
16
0784
CAM Titanium Blanks
2
Cleared 510(K)
K
16
0626
ATLANTIS Abutment for HIOSSEN ET implant
2
Cleared 510(K)
K
16
1030
ATLANTIS Abutment for CONELOG implant
2
Cleared 510(K)
K
15
3509
GPS Angled Abutment
2
Cleared 510(K)
K
16
0382
OT EQUATOR
2
Cleared 510(K)
K
16
0483
Burn-out Cylinder and Angled Screw Abutments
2
Cleared 510(K)
K
16
0248
ArgenIS Titanium Abutments
2
Cleared 510(K)
K
16
0158
NobelProcera HT ML FCZ Implant Bridge and Framework
2
Cleared 510(K)
K
15
3645
VITA ENAMIC Implant Solutions (IS)
2
Cleared 510(K)
K
16
0244
VARIOunite
2
Cleared 510(K)
K
15
3036
NobelDesign Software
2
Cleared 510(K)
K
15
2559
TruAbutment DS
2
Cleared 510(K)
K
15
3624
Neodent Implant System
2
Cleared 510(K)
K
15
1608
4plus6Line Abutment System
2
Cleared 510(K)
K
15
3779
Abutment for Bridges
2
Cleared 510(K)
K
15
2845
Allied Biocompat Abutment for Nobel Replace Interface
2
Cleared 510(K)
K
15
1984
Thommen Milling Abutment for CAD/CAM
2
Cleared 510(K)
K
15
1789
LOCATOR F-Tx Attachment System
2
Cleared 510(K)
K
15
1590
Straumann RN Gold Abutment for Bridge
2
Cleared 510(K)
K
15
1439
ATLANTIS ISUS
2
Cleared 510(K)
K
15
1194
KLOCKNER DENTAL IMPLANT ABUTMENTS (II)
2
Cleared 510(K)
K
15
1039
ATLANTIS Abutment for NobelActive 3.0
2
Cleared 510(K)
K
15
1621
BioHorizons CAD/CAM Abutments
2
Cleared 510(K)
K
15
2509
CAMLOG and CONELOG Abutments for Screw-retained Restorations (ASR)
2
Cleared 510(K)
K
15
1295
Biodenta Customized Abutment - Titanium
2
Cleared 510(K)
K
14
2211
OT EQUATOR
2
Cleared 510(K)
K
15
1798
Inclusive Titanium Abutments compatible with: Straumann synOcta Implant System
2
Cleared 510(K)
K
15
1432
NaturalLine Abutment
2
Cleared 510(K)
K
15
0203
Medentika CAD/CAM Abutments
2
Cleared 510(K)
K
15
1169
OsteoReady ZircoSeal Abutments
2
Cleared 510(K)
K
15
0669
Neoss TiBase, Neoss CoCr Abutments (Mono and Multi)
2
Cleared 510(K)
K
15
1375
Inclusive Titanium Abutments compatible with: Hiossen HG Implant System
2
Cleared 510(K)
K
14
3515
Inclusive® Zirconia Abutments compatible with: Zimmer Screw-Vent, Biomet 3i Certain and Nobel Biocare NobelReplace Implants
2
Cleared 510(K)
K
15
1564
Telio CAD Abutment Solutions
2
Cleared 510(K)
K
15
0899
Straumann CARES Titanium Alloy (TAN) Abutment
2
Cleared 510(K)
K
14
3051
ArgenIS Titanium Abutments
2
Cleared 510(K)
K
15
1324
Straumann Variobase for CEREC
2
Cleared 510(K)
K
15
1247
NC Straumann Screw Retained Abutments
2
Cleared 510(K)
K
15
0814
Straumann Screw-Retained Abutment
2
Cleared 510(K)
K
15
1157
NC Straumann Variobase Abutment for Bars/Bridges, RC Straumann Variobase Abutment for Bars/Bridges, NNC Straumann Variobase Abutment for Bars/Bridges, RN Straumann Variobase Abutment for Bars/Bridges, WN Straumann Variobase Abutment for Bars/Bridges
2
Cleared 510(K)
K
14
1970
DIGITEK TITANIUM ABUTMENT
2
Cleared 510(K)
K
15
0295
LOCATOR RTx
2
Cleared 510(K)
K
15
0367
Neodent Implant System
2
Cleared 510(K)
K
15
0296
Biodenta Customized Abutment-Hybrid
2
Cleared 510(K)
K
14
3505
Zimmer Patient-Specific Abutment, Internal Hex, Titanium
2
Cleared 510(K)
K
15
0250
SternSnap Angled Attachment
2
Cleared 510(K)
K
15
0012
CreoDent Solidex Customized Abutment
2
Cleared 510(K)
K
14
3528
Zimmer Cast-to Gold Abutments for the 3.1mmD Dental Implant System
2
Cleared 510(K)
K
14
2167
MEDENTIKA ABUTMENT SYSTEM
2
Cleared 510(K)
K
14
3337
CONELOG Titanium base CAD/CAM
2
Cleared 510(K)
K
14
2572
Zimmer Zfx Abutment for Zimmer 3.1mmD Implant System
2
Cleared 510(K)
K
14
2890
Straumann Variobase Abutment NNC, Straumann Variobase Abutment RN, Straumann Variobase Abutment WN, Straumann Variobase Abutment NC, Straumann Variobase Abutment RC, IPS e.max CAD MO Coping, IPS e.max CAD LT Crown, IPS e.max CAD HT Crown, coron CoCr Single Unit
2
Cleared 510(K)
K
14
1923
INCLUSIVE TITANIUM ABUTMENTS, COMPATIBLE WITH DENTSPLY IMPLANTS ANKYLOS C/X
2
Cleared 510(K)
K
14
2407
Straight Stud Attachment
2
Cleared 510(K)
K
14
2118
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH: STRAUMANN BONE LEVEL, NOBEL BIOCARE BRANAE
2
Cleared 510(K)
K
14
2115
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH: ZIMMER, BIOMET 3I, AND NOBEL BIOCARE IMPLANT
2
Cleared 510(K)
K
14
1457
DENTIUM IMPLANTIUM AND SUPERLINE ABUTMENTS
2
Cleared 510(K)
K
14
1544
ZIMMER ZFX TITANIUM ABUTMENT FOR BIOMET 3I CERTAIN IMPLANT SYSTEM
2
Cleared 510(K)
K
14
1211
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH STRAUMANN TISSUE LEVEL IMPLANTS
2
Cleared 510(K)
K
14
0600
SB ANCHOR
2
Cleared 510(K)
K
14
0507
HIOSSEN PROSTHETIC SYSTEM
2
Cleared 510(K)
K
14
0737
STRAUMANN CARES SCREW RETAINED BARS/BRIDGE
2
Cleared 510(K)
K
14
1871
Straumann Bone Level NC Angled Screw Retained Abutments
2
Cleared 510(K)
K
14
1120
ZIMMER ZFX TITANIUM ABUTMENT FOR STRAUMANN BONE LEVEL IMPLANT SYSTEM
2
Cleared 510(K)
K
13
2749
NOBELPROCERA OVERDENTURE BAR
2
Cleared 510(K)
K
13
3551
ZIMMER ZFX TITANIUM BASE ABUTMENT FOR TAPERED SCREWVENT IMPLANT SYSTEM
2
Cleared 510(K)
K
13
2214
ABUTMENT RP, ABUTMENT WP, BURN-OUT COPING, SCREWS, TITANIUM ADHESIVE BASE, ALLIGATOR ABUTMENT, SOLID ABUTMENT, RETENTIVE
2
Cleared 510(K)
K
13
1468
DENRACLE DENTAL ABUTMENT
2
Cleared 510(K)
K
13
4045
ZIMMER ZFX TITANIUM ABUTMENT, BASE ABUTMENT AND ABUTMENT BLANK FOR NOBELACTIVE IMPLANT SYSTEM
2
Cleared 510(K)
K
13
3421
STRAUMANN MAGELLAN(TM) ABUTMENT,PROTECTIVE CAP,TITANIUM COPINGS,GOLD CHOPINGS,BASAL SCREW
2
Cleared 510(K)
K
13
3791
ORA 0.4MM [S], ORA 1.0MM [S], ORA 2.0MM [S], ORA 3.0MM [S], ORA 4.0MM [S]
2
Cleared 510(K)
K
13
3377
NOBELPROCERA ANGULATED SCREW CHANNEL ABUTMENT REPLACE
2
Cleared 510(K)
K
13
0618
SFI-ANCHOR
2
Cleared 510(K)
K
13
3696
NEODENT IMPLANT SYSTEM
2
Cleared 510(K)
K
13
2814
SFI-BAR IMPLANT ABUTMENTS
2
Cleared 510(K)
K
13
2219
STRAUMANN(R) VARIOBASE(TM) ABUTMENT NNC, STRAUMANN(R) VARIOBASE(TM) ABUTMENT RN, STRAUMANN(R) VARIOBASE(TM) ABUTMENT WN,
2
Cleared 510(K)
K
13
2746
NOBELPROCERA ANGULATED SCREW CHANNEL ABUTMENT CONICAL CONNECTION
2
Cleared 510(K)
K
13
1644
ANKYLOS SYNCONE ABUTMENT 5(DEGREE)
2
Cleared 510(K)
K
13
2844
STRAUMANN CARES BONE LEVEL SCREW RETAINED BARS, STRAUMANN CARES BONE LEVEL SCREW RETAINED BRIDGES
2
Cleared 510(K)
K
13
0662
ET PROSTHETIC SYSTEM
2
Cleared 510(K)
K
13
2067
MULTI ANGLED ABUTMENT SYSTEM
2
Cleared 510(K)
K
13
2209
IPS E.MAX CAD ABUTMENT SOLUTIONS
2
Cleared 510(K)
K
12
2295
CORE 3D ABUTMENT SYSTEM FOR DIGITAL PROSTHETIC SOLUTIONS
2
Cleared 510(K)
K
13
1526
SFI-BAR
2
Cleared 510(K)
K
11
3738
CREODENT SOLIDEX CUSTOM ABUTMENT
2
Cleared 510(K)
K
13
1101
ITERO SOFTWARE
2
Cleared 510(K)
K
12
2988
KLOCKNER DENTAL IMPLANT ABUTMENTS
2
Cleared 510(K)
K
13
0183
SFI BAR ABUTMENTS
2
Cleared 510(K)
K
12
2424
ISUS IMPLANT SUPRASTRUCTURES
2
Cleared 510(K)
K
13
0408
ERA MICRO 23 FEMALE ABUTMENT, ERA MICRO 30 FEMALE ABUTMENT
2
Cleared 510(K)
K
13
0808
STRAUMANN HEALING ABUTMENTS, HEALING CAPS, CLOSURE SCREWS
2
Cleared 510(K)
K
12
3627
ET SMARTFIT ABUTMENT
2
Cleared 510(K)
K
13
0310
CERTAIN BELLATEK PROVISIONAL ABUTMENTS
2
Cleared 510(K)
K
12
0954
NOBELPROCERA PEEK ABUTMENTS
2
Cleared 510(K)
K
12
3491
BIODENTA DENTAL IMPLANT SYSTEM - MULTI-USE ABUTMENT
2
Cleared 510(K)
K
12
2559
BIODENTA DENTAL IMPLANT SYSTEM - ABUTMENTS
2
Cleared 510(K)
K
13
0216
ATLANTIS STRAUMANN BONE LEVEL ABUTMENT
2
Cleared 510(K)
K
12
3755
MULTI ANGLED ABUTMENT
2
Cleared 510(K)
K
12
4008
IPS E. MAX PRESS ABUTMENT SOLUTIONS FOR NOBEL BIOCARE
2
Cleared 510(K)
K
12
2602
NOBELPROCERA TI ABUTMENT CAMLOG PLATFORMS
2
Cleared 510(K)
K
11
3816
GC AADVA ABUTMENT- ZIRCONIUM-BO AC BH SV
2
Cleared 510(K)
K
12
1810
OSSEOSPEED ANGLED ABUTMENT EV
2
Cleared 510(K)
K
12
0822
STRAUMANN CARES VARIOBASE ABUTMENT NNC, STRAUMANN CARES VARIOBASE ABUTMENT RN, STRAUMANN CARES VARIOBASE ABUTMENT WN, ST
2
Cleared 510(K)
K
12
1117
NDX ABUTMENTS
2
Cleared 510(K)
K
12
2268
ANGLED XIVE MP ABUTMENT, ANGLED ANKYLOS
2
Cleared 510(K)
K
12
1843
NP-CAST ABUTMENT SYSTEM
2
Cleared 510(K)
K
12
1391
INCLUSIVE TITANIUM ABUTMENTS FOR CAMLOG SCREW-LINE IMPLANTS
2
Cleared 510(K)
K
12
0858
IMPLANT BAR
2
Cleared 510(K)
K
12
0873
ZIMMER ZFX ABUTMENT FOR NOBEL REPLACE IMPLANT SYSTEM
2
Cleared 510(K)
K
12
2192
NC TEMPORARY ABUTMENT, CAD-TEMP, PMMA RC TEMPORARY ABUTMENT, CAD-TEMP, PMMA RN TEMPORARY ABUTMENT, CAD-TEMP, PMMA WN TEM
2
Cleared 510(K)
K
12
1709
ZFX DENTAL CAD SYSTEM
2
Cleared 510(K)
K
12
0053
IPS E.MAX PRESS - ABUTMENT SOLUTIONS
2
Cleared 510(K)
K
12
1688
MULTI-UNIT ABUTMENTS WITH ANGULATIONS 17 AND 30 FOR TAPERED IMPLANT SYSTEM
2
Cleared 510(K)
K
12
0776
ABUTMENT FOR COMPETITIVE IMPLANT NOBEL ACTIVE CONNECTION
2
Cleared 510(K)
K
12
1334
VARIOECO
2
Cleared 510(K)
K
11
2787
KERATOR
2
Cleared 510(K)
K
12
0338
ATLANTIS IN ZIRCONIA FOR DENTSPLY ANKYLOS IMPLANT, ATLANTIS LATER ABUTMENT IN ZIRCONIA
2
Cleared 510(K)
K
11
3003
ATLANTIS(TM) ABUTMENT AND ATLANTIS(TM) CROWN ABUTMENT FOR KEYSTONE GENESIS IMPLANT, ATLANTIS GEMINI(TM) ABUTMENT...
2
Cleared 510(K)
K
11
1935
TI-BASE ABUTMENT, 1 CONNECT ABUTMENT
2
Cleared 510(K)
K
11
1421
SIRONA DENTAL CAD/CAM SYSTEM
2
Cleared 510(K)
K
11
2099
CONTOUR HEALER
2
Cleared 510(K)
K
11
2333
LRT ATTACHMENT
2
Cleared 510(K)
K
11
3606
NNC GOLD ABUTMENT FOR BRIDGES
2
Cleared 510(K)
K
11
2045
SIMPLELINE II ABUTMENT SYSTEM
2
Cleared 510(K)
K
11
3092
ZIMMER CONTOUR PROVISIONAL COPING
2
Cleared 510(K)
K
11
3410
NNC SOLID ABUTMENT NNC TEMPORARY COPING FOR COLID ABUTMENT NNC TEMPORARY CAP FOR COLID ABUTMENT
2
Cleared 510(K)
K
11
2730
ABUTMENT FOR COMPETITIVE IMPLANT STRAUMANN BONE LEVEL CONNECTION
2
Cleared 510(K)
K
11
3283
NNC CEMENTABLE ABUTMENT STRAIGHT,15 DEGREE ANGLE, TYPE A ,15 DEGREE ANGLE, TYPE B,NNC BASAL SCREW CEMENTABLE ABUTMENTS
2
Cleared 510(K)
K
11
1853
ANGLED TAPERED ABUTMENT
2
Cleared 510(K)
K
11
2138
ATLANTIS ABUTMENT IN ZIRCONIA FOR ASTRA TECH OSSEOSPEED PLUS IMPLANT
2
Cleared 510(K)
K
11
2280
STRAUMANN CARES SCREW-RETAINED BRIDGE TITANIUM, STRAUMANN CARES DOLDER BAR TITANIUM
2
Cleared 510(K)
K
11
1984
SPI VARIO ANGLED ABUTMENT
2
Cleared 510(K)
K
10
3291
BIOHORIZONS LASER-LOK ABUTMENTS FOR NOBEL BIOCARE
2
Cleared 510(K)
K
10
3691
BIOHORIZONS ABUTMENTS FOR ZIMMER
2
Cleared 510(K)
K
11
2259
NOBELACTIVE 3.0 GOLDADAPT ABUTMENTS
2
Cleared 510(K)
K
11
0308
PROSTHETIC SYSTEM
2
Cleared 510(K)
K
11
1390
SFI-BAR (R) IMPLANT ADAPTER SPI (R) ELEMENT PF 0 4.0 / H 3.0 / H 4.0 / H 5.0 / H 6.0, SFI-BAR (R) IMPLANT ADAPTER STRA..
2
Cleared 510(K)
K
11
0565
ABUTMENTS FOR COMPETITIVE IMPLANT SYSTEMS-NOBEL REPLACE
2
Cleared 510(K)
K
11
0580
NARROW CONNECTION STRAUMANN ANATOMIC IPS E.MAX ABUTMENTS
2
Cleared 510(K)
K
11
1852
ANODIZED HEALING COLLAR
2
Cleared 510(K)
K
11
1199
INTRA-LOCK DENTAL IMPLANTS WITH BLOSSOM 3.4MM IMPLANT ANGLED ABUTMENTS
2
Cleared 510(K)
K
11
0778
BIODENTA CUSTOMIZED ABUTMENT
2
Cleared 510(K)
K
10
3234
GC AADVA BO AC ABUTMENTS
2
Cleared 510(K)
K
11
1581
15 ESTHETIC ABUTMENT NOBELACTIVE 03.0 1.5MM, 15 ESTHETIC ABUTMENT NOBELACTIVE 03.0 3MM, 15 ESTHETIC ABUTMENT NOBELACTIVE
2
Cleared 510(K)
K
10
1005
ASTRA TECH IMPLANT SYSTEM, NEW COMPONENT
2
Cleared 510(K)
K
11
0171
NOBELPROCERA ZI ABUTMENT THOMMEN PLATFORMS
2
Cleared 510(K)
K
11
0640
ATLANTIS ABUTMENT FOR CAMLOG IMPLANT, DUPLICATE ABUTMENT, LATER ABUTMENT
2
Cleared 510(K)
K
11
0356
ATLANTIS CROWN ABUTMENT, ATLANTIS GEMINI +(TM) ABUTMENT
2
Cleared 510(K)
K
10
2804
SPI TITANIUM BASE FOR CAD/CAM
2
Cleared 510(K)
K
10
3759
ATLANTIS ABUTMENT IN ZIRCONIA FOR OSSEOSPEED TX PROFILE IMPLANT
2
Cleared 510(K)
K
10
2467
UTA AND UHA
2
Cleared 510(K)
K
10
3339
TDS ABUTMENT FOR FRIADENT XIVE
2
Cleared 510(K)
K
10
1608
BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS-ENCODE ABUTMENTS
2
Cleared 510(K)
K
10
1607
BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS - ENCODE ABUTMENTS
2
Cleared 510(K)
K
10
3280
BHDENTAL IMPLANT SYSTEM
2
Cleared 510(K)
K
10
3020
ATLANTIS ABUTMENT FOR KEYSTONE IMPLANT, ATLANTIS GEMINI ABUTMENT
2
Cleared 510(K)
K
10
1890
BALL ABUTMENT SYSTEM
2
Cleared 510(K)
K
10
3252
CAMLOG VARIO SR ABUTMENTS
2
Cleared 510(K)
K
10
0993
INCLUSIVE TITANIUM ABUTMENTS FOR ASTRA TECH OSSEOSPEED IMPLANTS
2
Cleared 510(K)
K
10
1465
STRAUMANN CARES BRIDGE; STRAUMANN CARES DOLDER BAR
2
Cleared 510(K)
K
10
2382
SFI-BAR IMPLANT ADAPTER STRAUMANN, SFI-BAR IMPLANT ADAPTER FOR NEOSS IMPLANT
2
Cleared 510(K)
K
10
2209
ENCODE PATIENT SPECIFIC ABUTMENT
2
Cleared 510(K)
K
10
1582
CAM STRUCTSURE BARS
2
Cleared 510(K)
K
10
0152
SIRONA CAD/CAM SYSTEM
2
Cleared 510(K)
K
10
0356
TDS PRECISION DENTAL BAR
2
Cleared 510(K)
K
10
0985
BIOHORIZONS SIMPLE SOLUTIONS WITH LASER-LOK
2
Cleared 510(K)
K
10
1714
NOBELPROCERA TI ABUTMENT THOMMEN PLATFORMS
2
Cleared 510(K)
K
10
1068
ACCUFIT DENTAL IMPLANT ABUTMENTS & SCREWS
2
Cleared 510(K)
K
10
1798
SPI VARIOMULTI ANGLED ABUTMENT
2
Cleared 510(K)
K
10
0245
HS/HG PROSTHETIC SYSTEM
2
Cleared 510(K)
K
10
1004
ATLANTIS ABUTMENT FOR DENTSPLY ANKYLOS IMPLANT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI + ABUTMENT
2
Cleared 510(K)
K
09
3643
MULTI- UNIT ABUTMENTS FOR STRAUMANN AND ASTRA TECH IMPLANT SYSTEMS
2
Cleared 510(K)
K
09
0081
TALLADIUM INTERNATIONAL IMPLANTOLOGY ABUTMENTS
2
Cleared 510(K)
K
09
3975
SIMPLER TOADSTOOL ABUTMENT, MODEL S19000-S19009
2
Cleared 510(K)
K
09
3780
ATLANTIS ABUTMENT FOR DENTSPLY IMPLANT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI + ABUTMENT
2
Cleared 510(K)
K
09
2857
VERICORE ABUTMENT IN TITANIUM FOR IMPLANT SYSTEMS
2
Cleared 510(K)
K
08
3876
SFI-BAR SYSTEM COMPLETE 2-IMPLANT AND 4-IMPLANT
2
Cleared 510(K)
K
09
3483
ATLANTIS ABUTMENT FOR NOBEL BIOCARE ACTIVE IMPLANT, ATLANTIS GEMINI ABUTMENT, GEMINI + ABUTMENT
2
Cleared 510(K)
K
09
1701
STRAUMANN MODIFIED DENTAL ABUTMENT
2
Cleared 510(K)
K
09
3113
ETKON ES1, MODEL 019.0001, ETKON VISUAL, STRAUMANN CADCAM ABUTMENT
2
Cleared 510(K)
K
09
2814
STRAUMANN DENTAL ABUTMENTS
2
Cleared 510(K)
K
09
2341
LOW PROFILE ABUTMENTS - INTERNAL AND EXTERNAL CONNECTION
2
Cleared 510(K)
K
09
2377
PLASTIC TEMPORARY ABUTMENTS, MODELS: PT341S, PT344S, PT341A, PT344A, PT451S, PT454S, PT451A, PT454A, PT561S, PT564S
2
Cleared 510(K)
K
09
2403
TI PREPABLE ABUTMENT, MODEL 1618, 1619, 1620
2
Cleared 510(K)
K
09
1848
NOBEL/PROCERA IMPLANT BRIDGE
2
Cleared 510(K)
K
09
1907
NOBELPROCERA IMPLANT BRIDGE ZIRCONIA
2
Cleared 510(K)
K
09
1920
ATLANTIS ABUTMENT IN ZIRCONIA, ATLANTIS GEMINI ABUTMENT FOR NOBEL REPLACE IMPLANTS, ATLANTIS GEMINI + ABUTMENT FOR NOBEL
2
Cleared 510(K)
K
09
2248
SPI CUSTOMIZABLE GINGIVA FORMER
2
Cleared 510(K)
K
09
1904
NOBELPROCERA ZI ABUTMENT
2
Cleared 510(K)
K
09
1756
NOBELPROCERA TI ABUTMENT
2
Cleared 510(K)
K
09
1693
TDS ZIRCONIA ABUTMENT FOR NOBEL BIOCARE BRANEMARK
2
Cleared 510(K)
K
09
1392
TDS TITANIUM ABUTMENT FOR NOBEL BIOCARE BRANEMARK
2
Cleared 510(K)
K
09
0976
VERICORE ABUTMENT IN ZIRCONIA FOR IMPLANT SYSTEMS
2
Cleared 510(K)
K
09
1026
TDS ABUTMENT FOR NOBEL BIOCARE REPLACE
2
Cleared 510(K)
K
09
0347
CAMLOG ABUTMENTS PS
2
Cleared 510(K)
K
09
0397
XPI ANGLED ABUTMENTS
2
Cleared 510(K)
K
09
0069
PROCERA IMPLANT BRIDGE OVERDENTURE
2
Cleared 510(K)
K
08
3480
INCLUSIVE ZIRCONIA ABUTMENT BLANKS
2
Cleared 510(K)
K
08
3871
ATLANTIS STRAUMANN BONE LEVEL ABUTMENT, ATLANTIS GEMINI STRAUMANN BONE LEVEL ABUTMENT, ATLANTIS GEMINI + STRAUMANN BONE
2
Cleared 510(K)
K
09
0723
HEX-LOCK SHORT ABUTMENT, MODEL SA341, SA342, SA451, SA452, SA561, SA562 SHORT HEALING CAP, MODEL SAHEAL4, SAHEAL5,
2
Cleared 510(K)
K
09
0153
SPI VARIOMULTI ANGLED ABUTMENT
2
Cleared 510(K)
K
08
3192
INCLUSIVE TITANIUM ABUTMENT BLANKS
2
Cleared 510(K)
K
08
1851
NEOSS ACCESS ABUTMENTS
2
Cleared 510(K)
K
08
3324
LOCATOR IMPLANT ANCHOR ATTACHMENT SYSTEM
2
Cleared 510(K)
K
08
3544
KAT IMPLANT SYSTEM
2
Cleared 510(K)
K
08
1396
SWISSPLANT DENTAL IMPLANT SYSTEM
2
Cleared 510(K)
K
08
1101
SPECTRA-SYSTEM ABUTMENTS 2008
2
Cleared 510(K)
K
08
3474
ZIMMER ANGLED CONTOUR ZIRCONIA ABUTMENT
2
Cleared 510(K)
K
08
1786
ZIOCERA & CONVERTIBLE SYSTEM
2
Cleared 510(K)
K
08
1460
TDS ABUTMENT
2
Cleared 510(K)
K
08
2299
VERICORE IMPLANT ABUTMENTS
2
Cleared 510(K)
K
08
3100
GOLDADAPT NON-ENGAGING NOBELACTIVE NP & RP, GOLDADAPT ENGAGING NOBELACTIVE NP & RP
2
Cleared 510(K)
K
08
3141
SIMPACT ENDOSSEOUS DENTAL IMPLANT SYSTEM
2
Cleared 510(K)
K
08
2545
STRAUMANN NN CARES TITANIUM AND CERAMIC ABUTMENTS
2
Cleared 510(K)
K
08
1666
ATLANTIS, ATLANTIS GEMINI, ATLANTIS GEMINI+ ABUTMENTS FOR ASTRA OSSEOSPEED 3.0 IMPLANTS
2
Cleared 510(K)
K
08
2764
STRAUMANN WN CARES TITANIUM ABUTMENT
2
Cleared 510(K)
K
08
0164
ZIMMER PATIENT-SPECIFIC CERAMIC ABUTMENT
2
Cleared 510(K)
K
08
1575
HU/HS/HG PROSTHETIC SYSTEM
2
Cleared 510(K)
K
08
1157
ACCUFRAME
2
Cleared 510(K)
K
08
0864
CAM STRUCTSURE PRECISION MILLED BARS
2
Cleared 510(K)
K
08
1186
CONCAVE RN HEALING CAP
2
Cleared 510(K)
K
08
0598
MINI DRIVE-LOCK DENTAL IMPLANT SYSTEM PROSTHETICS
2
Cleared 510(K)
K
07
3217
INCLUSIVE IMPLANT ABUTMENTS
2
Cleared 510(K)
K
08
0397
AMERICAN DENTAL IMPLANT ABUTMENT SYSTEM
2
Cleared 510(K)
K
08
1005
P.004 NC CARES TITANIUM AND CERAMIC ABUTMENTS
2
Cleared 510(K)
K
08
0239
P.004 ABUTMENTS, P.004 TEMPORARY COPINGS, P.004 PROTECTIVE CAPS, P.004 PERMANENT COPINGS
2
Cleared 510(K)
K
07
2730
FRIADENT CERCON AND ANKYLOS CERCON BALANCE ABUTMENTS
2
Cleared 510(K)
K
08
0286
CEMENTABLE ABUNTMENTS; TEMPORARY COPINGS; PROTECTIVE CAPS
2
Cleared 510(K)
K
07
3345
CERTAIN CONTOURED MARGIN CERAMIC ABUTMENT
2
Cleared 510(K)
K
07
3553
CAMLOG IMPLANT SYSTEM ABUTMENTS
2
Cleared 510(K)
K
07
3540
ATLANTIS ABUTMENT IN ZIRCONIA FOR BIOHORIZONS IMPLANT
2
Cleared 510(K)
K
07
2055
LAVA FRAME, LAVA FRAME SHADE
2
Cleared 510(K)
K
07
2129
NOBELACTIVE ZIRCONIA ABUTMENT
2
Cleared 510(K)
K
07
2856
SPI VARIOMULTI ABUTMENT
2
Cleared 510(K)
K
07
3258
ATLANTIS ABUTMENT FOR BIOHORIZON IMPLANTS, ATLANTIS GEMINI ABUTMENT FOR BIOHORIZON IMPLANTS, ATLANTIS GEMINI + ABUTMENT
2
Cleared 510(K)
K
07
2100
GC AADVA ABUTMENT
2
Cleared 510(K)
K
07
3073
ANKYLOS TEMPORARY ABUTMENT BALANCE
2
Cleared 510(K)
K
07
3628
SYNOCTA ABUTMENTS
2
Cleared 510(K)
K
07
2570
NOBELACTIVE MULTI UNIT ABUTMENT
2
Cleared 510(K)
K
07
2642
BIOMET 3I DENTAL ABUTMENTS AND RESTORATIVE COMPONENTS
2
Cleared 510(K)
K
07
3141
SPI ART ABUTMENT
2
Cleared 510(K)
K
07
2878
MODIFICATION TO: LOCATOR IMPLANT ANCHOR
2
Cleared 510(K)
K
07
0228
IMPLANTIUM PROSTHETICS
2
Cleared 510(K)
K
07
3032
PRIMACONNEX SD ESTHETIC CONTOUR ZI ABUTMENTS
2
Cleared 510(K)
K
07
2483
ATLANTIS ABUTMENT IN ZIRCONIA FOR 3I CERTAIN MICROAMINI IMPLANTS, GEMINI ABUTMENT IN ZIRCONIA FOR ASTRA IMPLANTS
2
Cleared 510(K)
K
07
2241
PRIMACONNEX CAD/CAM ABUTMENT SYSTEM
2
Cleared 510(K)
K
07
1838
NEOSS VARIOUS TITANIUM ABUTMENTS
2
Cleared 510(K)
K
07
1888
STRAUMANN P.004 RC GOLD ABUTMENT FOR BRIDGES
2
Cleared 510(K)
K
07
2679
P.004 ABUTMENTS
2
Cleared 510(K)
K
07
2572
PRIMACONNEX RD AND WD ESTHETIC CONTOUR ZI ABUTMENTS
2
Cleared 510(K)
K
07
1946
ATLANTIS, GEMINI AND GEMINI+ ABUTMENTS IN ZIRCONIA FOR ASTRA IMPLANTS
2
Cleared 510(K)
K
07
2624
ASTRA TECH IMPLANT SYSTEM, NEW COMPONENT
2
Cleared 510(K)
K
07
2497
P.004 NC GOLD ABUTMENT FOR CROWNS
2
Cleared 510(K)
K
07
1919
P.004 ABUTMENTS
2
Cleared 510(K)
K
07
1357
P.004 NC ANATOMIC ABUTMENTS
2
Cleared 510(K)
K
07
0478
P.004 RC TEMPORARY ABUTMENT, P.004 TEMPORARY HEALING ABUTMENT (CAP)
2
Cleared 510(K)
K
07
1453
SPI EASY 4.0 ABUTMENT
2
Cleared 510(K)
K
07
2151
P.004 RC CARES TITANIUM AND CERAMIC ABUTMENTS
2
Cleared 510(K)
K
07
0549
STRAUMANN P.004 RC GOLD ABUTMENT
2
Cleared 510(K)
K
07
1551
QUICKBRIDGE TM CYLINDER AND CAP
2
Cleared 510(K)
K
07
2071
STRAUMANN P.004 CEMENTABLE ABUTMENTS, TEMPORARY COPINGS AND PROTECTIVE CAPS
2
Cleared 510(K)
K
07
1213
CAMLOG LOGFIT PROSTHETIC SYSTEM
2
Cleared 510(K)
K
07
1585
P.004 HEALING ABUTMENTS AND CLOSURE SCREWS
2
Cleared 510(K)
K
07
0744
NARROW NECK TEMPORARY COPING
2
Cleared 510(K)
K
06
3768
TITANIUM SCALLOPED ABUTMENT
2
Cleared 510(K)
K
07
0833
ATLANTIS ABUTMENT FOR ASTRA IMPLANT
2
Cleared 510(K)
K
07
0533
BTI ENDOSSEOUS DENTAL IMPLANT ANGLED ABUTMENTS
2
Cleared 510(K)
K
06
3106
REVOIS IMPLANT SYSTEM
2
Cleared 510(K)
K
07
0562
EZ PLUS IMPLANT SYSTEM
2
Cleared 510(K)
K
06
3789
WN SYNOCTA GOLD ABUTMENT
2
Cleared 510(K)
K
06
1277
STRAUMANN COMPUTER AIDED RESTORATION SERVICE (C.A.R.E.S.) CERAMIC COPING
2
Cleared 510(K)
K
06
3403
CONICAL ANGLED ABUTMENT
2
Cleared 510(K)
K
06
3734
ATLANTIS ABUTMENT IN ZIRCONIA FOR 3I CERTAIN INTERFACE
2
Cleared 510(K)
K
06
2197
ATLANTIS ABUTMENT FOR 3I CERTAIN MICRO MINI; GEMINI AND GEMINI+ ABUTMENT
2
Cleared 510(K)
K
06
3592
ADAPTER PS RP-NP, 34551, ADAPTER PS WP-RP,34552, ABUTMENT SCREW PS RP-NP, 34553, ABUTMENT SCREW PS WP-RP, 34554
2
Cleared 510(K)
K
06
2069
ATLANTIS ABUTMENT FOR 3I MICROMINI IMPLANT
2
Cleared 510(K)
K
06
2277
ATLANTIS ABUTMENT IN ZIRCONIA FOR NOBEL BIOCARE REPLACE
2
Cleared 510(K)
K
06
2749
SBF 15 ESTHETIC ABUTMENT 1MM NP, MODEL 33699, SFB 15 ESTHETIC ABUTMENT 1MM RP, MODEL 33701, CFB 15 ESTHETIC ABUTMENT 2MM
2
Cleared 510(K)
K
06
1567
BIOHORIZONS CERAMIC ABUTMENT
2
Cleared 510(K)
K
06
2493
LAVA SOFTWARE
2
Cleared 510(K)
K
06
2876
PRIMACONNEX CERAMIC ABUTMENTS
2
Cleared 510(K)
K
06
1847
ZIMMER CONTOUR CERAMIC ABUTMENT, MODELS ZRA341S, ZRA342S, KRA451S, ZRA452S
2
Cleared 510(K)
K
06
1529
PROCERA ZIRCONIA ABUTMENT FOR CAMLOG IMPLANT SYSTEM
2
Cleared 510(K)
K
06
1478
PROCERA TITANIUM ABUTMENT FOR ASTRATECH AND CAMLOG IMPLANT SYSTEMS
2
Cleared 510(K)
K
06
1477
MULTI-UNIT ABUTMENTS FOR ASTRATECH, CAMLOG AND ANKYLOS IMPLANT SYSTEMS
2
Cleared 510(K)
K
06
1807
SPI ART ABUTMENTS
2
Cleared 510(K)
K
05
3654
ATLANTIS ABUTMENT FOR NOBEL REPLACE INTERFACE
2
Cleared 510(K)
K
05
2957
IMPLANTIUM PROSTHETICS
2
Cleared 510(K)
K
06
1969
PREFORMANCE POSTS AND TEMPORARY CYLINDERS
2
Cleared 510(K)
K
05
3373
ATLANTIS ABUTMENT FOR ZIMMER INTERFACE
2
Cleared 510(K)
K
06
1043
ZIMMER CONTOUR RESTORATIVE SYSTEM
2
Cleared 510(K)
K
06
0063
LEGACY ABUTMENT SYSTEM
2
Cleared 510(K)
K
06
0880
ZIMMER DENTAL ONE PIECE TAPERED ABUTMENT, MODELS TAC1, TACW1, TA5C1
2
Cleared 510(K)
K
06
1177
PROVIDE TEMPORARY CYLINDER
2
Cleared 510(K)
K
05
3450
ATLANTIS ABUTMENT FOR ZIMMER INTERFACE
2
Cleared 510(K)
K
06
0291
PREFORMANCE TEMPORARY CYLINDER
2
Cleared 510(K)
K
05
3125
PROCERA BRIDGE ZIRCONIA
2
Cleared 510(K)
K
05
3068
PROCERA BRIDGE LAMINATE, MODEL 40-4002
2
Cleared 510(K)
K
05
3050
PROCERA BRIDGE ALUMINA
2
Cleared 510(K)
K
05
2823
IMPLANTIUM ABUTMENTS
2
Cleared 510(K)
K
05
1636
CAMLOG DENTAL IMPLANT ABUTMENTS, HEALING CAPS, AND ACCESSORIES
2
Cleared 510(K)
K
05
3099
BIOHORIZONS PLASTIC TEMPORARY ABUTMENTS
2
Cleared 510(K)
K
05
3602
PROCERA SOFTWARE, MODEL 33145
2
Cleared 510(K)
K
05
3170
PREFORMANCE POSTS
2
Cleared 510(K)
K
05
3091
PROCERA IMPLANT BRIDGE ZIRCONIA
2
Cleared 510(K)
K
05
3643
STAGE- 1 TEMPORARY/HEALING CAP, MODEL 42021-42026
2
Cleared 510(K)
K
05
2272
STRAUMANN COMPUTER AIDED RESTORATION SERVICE
2
Cleared 510(K)
K
05
2885
ZYGOMA 17 ABUTMENT MULTI-UNIT RP 2MM, MODEL 29314; ZYGOMA 17 ABUTMENT MULTI-UNIT RP 3MM, MODEL 29315
2
Cleared 510(K)
K
05
2648
MODIFICATION TO 3I PATIENT-SPECIFIC DENTAL ABUTMENTS AND OVERDENTURE BARS
2
Cleared 510(K)
K
05
1501
ZIRACE
2
Cleared 510(K)
K
05
2070
ATLANTIS ABUTMENT IN ZIRCONIA, ATLANTIS GEMINI ABUTMENT IN ZIRCONIA, ATLANTIS GEMEINI + ABUTMENT IN ZIRCONIA
2
Cleared 510(K)
K
05
2600
ZIMMER DENTAL HEX-LOCK PREPARED ABUTMENT (STRAIGHT & ANGLED)
2
Cleared 510(K)
K
05
1527
SPI EASY TEMPORARY CAP
2
Cleared 510(K)
K
05
1652
ATLANTIS ABUTMENT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI+ ABUTMENT
2
Cleared 510(K)
K
05
1011
ENDOSSEOUS DENTAL IMPLANT ABUTMENT
2
Cleared 510(K)
K
04
3428
RELIADENT DENTAL IMPLANT SYSTEM
2
Cleared 510(K)
K
05
1717
RN SYNOCTA TEMPORARY MESO ABUTMENT
2
Cleared 510(K)
K
05
0444
NOBELREPLACE ADAPTER, MODEL 32412
2
Cleared 510(K)
K
05
0208
FRIADENT ESTHETICAP
2
Cleared 510(K)
K
05
0641
ZYGOMA TIUNITE
2
Cleared 510(K)
K
04
2715
TITAN DENTAL IMPLANT ATTACHMENT
2
Cleared 510(K)
K
05
0052
ATLANTIS ABUTMENT FOR STRAUMANN INTERFACE
2
Cleared 510(K)
K
04
3190
SCALLOPED ENDOPORE ENDOSSEOUS DENTAL IMPLANT SYSTEM
2
Cleared 510(K)
K
04
2466
X-2 IMPLANT ABUTMENT; BAR MALE; DISTAL EXTENSION MALE
2
Cleared 510(K)
K
04
3042
PROCERA IMPLANT BRIDGE, MODELS 15-1001, 15-1002, 15-1051, 15-1052
2
Cleared 510(K)
K
04
2658
PROCERA ABUTMENT BRANEMARK, MODELS 10-4001, 10-4004, 10-5001, 10-5004, 10-6001, 10-6004
2
Cleared 510(K)
K
04
1070
STRAUMANN TEMPORARY COPING
2
Cleared 510(K)
K
04
1275
PROCERA ABUTMENT OCTAGON
2
Cleared 510(K)
K
04
1236
PROCERA IMPLANT BRIDGE, MODELS 15-1001, 15-1002, 15-1051, 15-1052
2
Cleared 510(K)
K
04
1295
RN SYNOCTA UCLA GOLD ABUTMENT FOR THE STRAUMANN DENTAL IMPLANT
2
Cleared 510(K)
K
04
0573
NOBEL BIOCARE PERMANENT CENTRIC POST, MODELS 31234, 31235, 31236
2
Cleared 510(K)
K
03
4035
3I PATIENT-SPECIFIC OVERDENTURE BAR
2
Cleared 510(K)
K
04
0205
INTRA-LOCK INTERNATIONAL ANGLED PROSTHETIC ABUTMENTS
2
Cleared 510(K)
K
04
0539
ELLIPTIC MATRIX
2
Cleared 510(K)
K
03
3724
NOBEL BIOCARE CENTRIC POST, MODELS 31234, 31235 AND 31236
2
Cleared 510(K)
K
03
3346
SPI EASY DENTAL IMPLANT PROTECTIVE CAP
2
Cleared 510(K)
K
03
3243
ITI SYNOCTA MESO ABUTMENTS
2
Cleared 510(K)
K
03
2498
DENTAL IMPLANT COPING (PROSTHETIC ACCESSORIES TO THE ITI DENTAL IMPLANT SYSTEM)
2
Cleared 510(K)
K
03
2448
ALTATEC CERAMIC ABUTMENT
2
Cleared 510(K)
K
03
1747
SPI DENTAL IMPLANT ABUTMENTS
2
Cleared 510(K)
K
03
1719
ESTHETIC ZIRCONIA ABUTMENT
2
Cleared 510(K)
K
02
3645
SPI EASY DENTAL IMPLANT ABUTMENT
2
Cleared 510(K)
K
02
3631
ASTRA TECH DENTAL IMPLANTS-CERAMIC ABUTMENTS
2
Cleared 510(K)
K
02
2795
MODIFICATION TO THE MAESTRO SYSTEM
2
Cleared 510(K)
K
02
1460
OCO DENTAL IMPLANT
2
Cleared 510(K)
K
01
4175
SULZER DENTAL CERAMIC SYSTEM-HEXLOCK
2
Cleared 510(K)
K
97
4150
PROCERA PREPARABLE ABUTMENT SYSTEM
2
Cleared 510(K)
K
97
2475
AURADAPT AUBTMENT SYSTEM
2
Cleared 510(K)
K
97
1706
TIADAPT ABUTMENT SYSTEM
2
Cleared 510(K)
K
97
0073
BIO-ESTHETIC INDIRECT ABUTMENT
2
Cleared 510(K)
K
96
1736
17 ANGULATED ABUTMENT
2
Cleared 510(K)
K
96
1728
MIRUSCONE ABUTMENT SYSTEM
2
Cleared 510(K)
K
92
5349
ONE SYSTEM TAPERED TITANIUM ABUTMENTS
2
Cleared 510(K)
K
92
5779
BRANEMARK SYSTEM TITANIUM HEALING ABUTMENTS
2
Cleared 510(K)
K
92
5769
BRANEMARK SYSTEM ABUTMENTS COMPLETE
2
Cleared 510(K)
NKJ
Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
1
Product Code
NME
Bur, Diamond Coated, Reprocessed
1
Product Code
NOF
System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
2
Product Code
NPK
Barrier, Synthetic, Intraoral
2
Product Code
NPL
Barrier, Animal Source, Intraoral
2
Product Code
NPM
Bone Grafting Material, Animal Source
2
Product Code
NPZ
Bone Grafting Material, Dental, With Biologic Component
3
Product Code
NQA
Biologic Material, Dental
3
Product Code
NRQ
Blade-Form Endosseous Dental Implant
2
Product Code
NUN
Bone Grafting Material, Human Source
2
Product Code
NUX
Cleanser, Denture, Prescription
1
Product Code
NYD
Endodontic Kit
2
Product Code
OAT
Implant, Endosseous, Orthodontic
2
Product Code
NYE
Fixture Mount Kit
1
Product Code
OFW
Restorative Instrument And Component Tray
2
Product Code
OFY
Dental Implant Surgical Tray
1
Product Code
OIV
Dental Amalgam
2
Product Code
PHR
Diammine Silver Fluoride Dental Hypersensitivity Varnish
2
Product Code
PME
External Cleaning Solution
2
Product Code
PNP
Dental Abutment Design Software For Dental Laboratory
2
Product Code
POW
Crown And Bridge, Long-Term Temporary, Resin
2
Product Code
PZY
Additively Manufactured, Preformed, Resin Denture Tooth
2
Product Code
QJK
Intraoral Camera
2
Product Code
QRQ
Non-Irrigation Endosseous Dental Implant Drill Bits
1
Product Code
Surgical Devices
CFR Sub-Part
Therapeutic Devices
CFR Sub-Part
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 17 March 2023 at 11:04 pm
DE
/
prosthetic-devices
/
NHA
/
K080397
View Source
AMERICAN DENTAL IMPLANT ABUTMENT SYSTEM
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K080397
510(k) Type
Traditional
Applicant
AMERICAN DENTAL IMPLANT CORPORATION
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/6/2008
Days to Decision
83 days
Submission Type
Statement
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Diagnostic Devices
General Hospital and Personal Use Miscellaneous Devices
Miscellaneous
Miscellaneous Devices
Physical Medicine Diagnostic Devices
Physical Medicine Prosthetic Devices
Physical Medicine Therapeutic Devices
Prosthetic Devices
DZS
Capsule, Dental, Amalgam
DYH
Adhesive, Bracket And Tooth Conditioner, Resin
DZE
Implant, Endosseous, Root-Form
EBC
Sealant, Pit And Fissure, And Conditioner
EBD
Coating, Filling Material, Resin
EBE
Coating, Denture Hydrophilic, Resin
EBF
Material, Tooth Shade, Resin
EBG
Crown And Bridge, Temporary, Resin
EBH
Material, Impression Tray, Resin
EBI
Resin, Denture, Relining, Repairing, Rebasing
EBL
Pin, Retentive And Splinting, And Accessory Instruments
EBO
Denture Repair Kit
EBP
Reliner, Denture, Over The Counter
EFD
Amalgamator, Dental, Ac-Powered
EFT
Cleanser, Denture, Over The Counter
EGG
Attachment, Precision, All
EHE
Dispenser, Mercury And/Or Alloy
EHO
Bar, Preformed
EHP
Clasp, Preformed
EHQ
Cusp, Preformed
EHR
Pad, Denture, Over The Counter
EHS
Cushion, Denture, Over The Counter
EIT
Applicator, Rapid Wax, Dental
EJH
Alloy, Metal, Base
EJJ
Alloy, Amalgam
EJK
Liner, Cavity, Calcium Hydroxide
EJL
Bur, Dental
EJP
Articulators
EJS
Alloy, Other Noble Metal
EJT
Alloy, Gold-Based Noble Metal
EJW
Clasp, Wire
EJX
Anchor, Preformed
EKL
Point, Silver, Endodontic
EKM
Gutta-Percha
EKN
Point, Paper, Endodontic
EKO
Denture Preformed (Partially Prefabricated Denture)
ELE
Implant, Subperiosteal
ELJ
Teeth, Artificial, Posterior With Metal Insert
ELK
Teeth, Artificial, Backing And Facing
ELL
Teeth, Porcelain
ELM
Denture, Plastic, Teeth
ELN
Teeth, Preformed Gold Denture
ELO
Cusp, Gold And Stainless Steel
ELR
Post, Root Canal
ELS
Splint, Endodontic Stabilizing
ELW
Material, Impression
ELY
Mercury
ELZ
Crown, Preformed
EMA
Cement, Dental
EMB
Zinc Oxide Eugenol
JER
Cleaner, Denture, Mechanical
KCR
Facebow
KCS
Pantograph
KIF
Resin, Root Canal Filling
KLE
Agent, Tooth Bonding, Resin
KOL
Adhesive, Denture, Carboxymethylcellulose Sodium (32%) And Ethylene-Oxide Homopolymer
KOM
Adhesive, Denture, Acacia And Karaya With Sodium Borate
KON
Adhesive, Denture, Polyacrylamide Polymer (Modified Cationic)
KOO
Adhesive, Denture, Polyvinyl Methylether Maleic Acid Calcium-Sodium Double Salt
KOP
Adhesive, Denture, Karaya
KOQ
Adhesive, Denture, Carboxymethylcellulose Sodium (40-100&)
KOR
Adhesive, Denture, Karaya With Sodium Borate
KOS
Adhesive, Denture, Carboxymethylcellulose Sodium And Cationic Polyacrylamide Polymer
KOT
Carboxymethylcellulose Sodium Or Polyvinyl Methylether Maleic Acid Calcium-Sodium
KXR
Applicator, Resin
KXW
Adhesive, Denture, Carboxymethylcellulose Sodium (49%) And Ethylene-Oxide Homopolymer
KXX
Adhesive, Denture, Karaya And Ethylene-Oxide Homopolymer
KXY
Polyvinyl Methylether Maleic Anhydride &/Or Acid Copolymer & Carboxymethylce
KZN
Scanner, Color
KZO
Ink, Arch Tracing
KZP
Solution, Cement Dissolving
LBH
Varnish, Cavity
LPK
Bone Grafting Material, For Dental Bone Repair
LYC
Bone Grafting Material, Synthetic
LZD
Joint, Temporomandibular, Implant
MMT
Resin, Root Canal Filling Containing Chloroform
MMU
Adhesive, Denture, Acacia And Karaya With Sodium Borate > 12% By Weight
MPI
Glenoid Fossa Prosthesis
MPJ
Interarticular Disc Prosthesis (Interpositional Implant)
MPL
Mandibular Condyle Prosthesis
MZW
Dental Cement W/Out Zinc-Oxide Eugenol As An Ulcer Covering For Pain Relief
NDP
Accessories, Implant, Dental, Endosseous
NFE
Materials, Polytetrafluoroethylene Vitreous Carbon, For Maxillofacial Alveolar Ridge Augmentation
NHA
Abutment, Implant, Dental, Endosseous
K
21
1396
Neoss Individual Prosthetics
K
22
0252
High Retention Attachment System
K
21
3063
TLX SRAs and TLX Gold Abutments
K
21
3432
MIS Angulated multi-unit abutments
K
21
2628
DESS Dental Smart Solutions
K
21
2676
Osteon Precision Milled Suprastructure
K
21
0356
Noris Medical Dental Implants System
K
21
0826
Healing Abutment, Cover Screw
K
20
1323
INNO SLA Submerged Implant System
K
21
3391
High Retention Attachment System
K
21
2730
BellaTek Encode Emergence Healing Abutments
K
21
2577
DESS Dental Smart Solutions
K
21
2664
Sherlock
K
21
1871
FAICO Dental Implant System and CAD/CAM Abutments
K
21
3449
DS Implants abutments provided with the EV connection
K
20
3808
Multi-unit Abutment, Multi-unit Angled Abutment
K
20
3750
Straumann CARES P-Series CAD/CAM System
K
21
2108
Dynamic TiBase
K
20
3649
TruAbutment DS, TruBase
K
21
0410
s-Clean Pre-Milled Abutment Mini
K
20
3344
Premilled Titanium Block System
K
21
0362
s-Clean Pre-Milled Abutment
K
20
0193
Kisses Plus Implant System
K
20
3464
DESS Dental Smart Solutions
K
20
3542
Neodent Implant System - Mini Abutment 60°
K
21
1225
MIS Ti-base abutment
K
21
0903
IS Multi Unit Abutment System
K
20
2579
TruAbutment DS, TruBase
K
20
3456
Straumann CARES M-Series CAD/CAM System
K
20
1842
TruBase S
K
20
3240
AccelX Abutments
K
20
2909
CreoDent Solidex Customized Abutment
K
20
1197
TruAbutment DS, TruBase S
K
20
1681
Straumann Immediate Temporary Abutments
K
20
3252
Multi-unit Abutments for CONELOG
K
20
1860
Elos Accurate Hybrid Base
K
20
3355
Straumann TLX Novaloc and Cementable Abutments
K
19
2742
Straumann Variobase C
K
20
2282
Neodent Implant System - Zirconia Implant System
K
20
2026
Blue Sky Bio CAD-CAM Abutments
K
20
2095
CreoDent Solidex Customized Abutment and Screw
K
20
1711
CARES Screw - Retained Bars and Bridges (SRBB)
K
20
2452
NobelProcera Zirconia Implant Bridge
K
20
2418
Magic UCLA Abutment System
K
20
2269
PRE-MILLED Abutment
K
19
3193
Telio CAD Abutment Solutions- extra systems
K
19
3084
TIB Abutment System
K
20
0827
LOCATOR R-Tx
K
20
0597
Straumann BLX Gold Abutments
K
19
3408
Sirona Dental CAD/CAM System with CEREC Chairside Software
K
19
3046
Straumann® Retentive System – Novaloc TiN Abutments
K
20
0355
Duranext Abutments
K
20
1621
Magicore II System
K
19
1152
MIS Ti-base Abutment
K
19
1913
TruAbutment DS
K
20
0753
IBS Implant System II
K
19
3404
UF(II) Bar holder abutment
K
19
2218
Custom Legacy and Custom InterActive Titanium Abutments
K
19
2108
Panthera Dental Milled Bars
K
19
2401
Straumann Screw-Retained Abutments
K
20
0040
Universal Base Conical Connection (CC)
K
19
3078
MIS CONNECT Conical Connection System
K
19
3335
Sherlock
K
19
3425
Pre-Milled Blank
K
19
3529
ATLANTIS Abutment for MIS Conical Connection Implants
K
19
3064
Atlantis suprastructures
K
19
3274
Rodo Abutment System
K
20
0189
Luna Dental Implant System- Healing Abutment
K
19
2263
UCLA CCM Abutment
K
19
2614
Meg-Ball Attachment System, Meg-Loc Abutment, Meg-Magnet Abutment
K
19
1919
Elos Accurate Hybrid Base
K
19
1890
Elos Accurate Customized Abutment
K
18
3106
TruAbutment DS
K
19
2436
Healing Abutments and Cover Screws
K
19
1123
Multi-unit Abutments
K
19
2893
Straumann Ceramic Healing Abutments
K
19
2457
Elos Accurate Customized Abutment
K
19
2229
Neodent Implant System- GM Titanium Base for Bridge
K
19
2522
TSV BellaTek Express and BellaTek Flex Abutments
K
19
1250
Southern Implants PEEK Abutments
K
19
1191
Neodent Implant System - Temporary Abutments
K
19
1986
DESS Dental Smart Solutions
K
19
1634
Scan Abutments and Comfort Caps
K
19
2029
Straumann PUREloc abutments
K
19
1458
Legacy SMARTBase Abutments
K
19
0048
UF(II) Anatomic abutment
K
19
1382
IPS e.max CAD Abutment Solutions- extra systems
K
19
0491
Blue Sky Bio Zygomatic Implant System
K
19
1222
Inclusive Titanium Abutments compatible with: Dentsply Implants Astra Tech Implant System EV
K
18
2455
A.B. DENTAL DEVICES Dental Implants System
K
18
2091
Osstem Abutment System
K
18
3079
Conometric Abutments
K
18
3138
Certain BellaTek Express and BellaTek Flex Abutments
K
19
0654
Straumann CI RD Ceramic Healing Caps
K
19
0299
Elos Accurate® Customized Abutment
K
19
0097
Straumann CARES Screw-Retained Bridges and Bars
K
18
3580
Panthera Dental Milled Bars
K
17
3570
SD Abutment
K
19
0082
Straumann BLX Variobase Abutment
K
18
2246
MIST IC
K
19
0040
Straumann BLX Line Extension - New Abutments
K
18
3518
Preat Abutments
K
18
1580
Cortex CAD/CAM Abutments
K
18
2228
MIS LOCKiT Abutments System, OT-Equators and Ball Attachments
K
18
0564
Medentika Abutment System, Medentika CAD/CAM Abutments, Medentika CAD/CAM TiBases
K
18
1037
DIO CAD/CAM Abutment
K
18
1869
On1 Universal Abutment
K
18
1381
A.B. Dental Devices Dental Implants System
K
18
0184
Zeramex(R) XT Dental Implant System, NobelPearl Dental Implant System
K
18
0899
Universal Base Abutment
K
18
1520
Sirona Dental CAD/CAM System
K
17
3945
Straumann SC Variobase Abutments
K
18
0998
BioHorizons CAD/CAM Bars
K
17
1532
TruBase S
K
18
1359
InterActive SMARTBase Abutments
K
18
1189
ATLANTIS Conus Structure
K
17
3968
Straumann Variobase for Bridge/Bar Cylindrical
K
17
3908
DESS Dental Smart Solutions
K
18
0609
Rodo Smilekey
K
17
2430
ArgenIS Titanium Abutments
K
17
2640
Dentium Implantium & SuperLine Prosthetics
K
16
2021
3.0 Dynamic TiBase
K
17
3902
Neodent Implant System – GM Line
K
17
1409
OT EQUATOR
K
17
3379
Straumann Variobase for Crown AS
K
17
3326
MIS CONNECT Conical Connection Abutment
K
17
3120
CCM Abutment System
K
17
1649
Straumann CARES M-Series CAD/CAM System
K
17
2160
Southern Implants PEEK Abutments
K
16
1989
PREMIUM Implant Systems SHELTA Implant Systems
K
17
3466
Panthera Dental Milled Bars
K
17
2304
TruAbutment DS
K
17
1799
Elos Accurate Customized Abutment, Elos Prosthetic Screw
K
17
1622
Dentium Ti-Base
K
17
0421
ET Hybrid Abutment
K
17
2798
Straumann CARES Abutments CoCr
K
17
2854
NobelPerfect Abutments
K
17
3374
TSV BellaTek Encode Healing Abutments
K
17
1773
Straumann n!ce Glass Ceramic A14 Blocks
K
17
2225
Atlantis Abutment for MIS Implant
K
17
1694
s-Clean TiN Coating Abutments
K
17
1466
NobelDesign, DTX Studio Design
K
17
1757
Straumann Screw Retained Abutments
K
17
0022
Klockner Vega TiBase for CEREC
K
17
0080
Neodent Implant System - CM Pro PEEK Abutment
K
17
1142
Healing Cap Multi-Unit Titanium
K
17
1922
Anatotemp Anatomic Dental Implant Healing Abutment
K
16
2848
Straumann CARES Golden Ti/TiN Abutments
K
17
0013
Eztetic BellaTek Encode Healing Abutments
K
17
0838
Medentika CAD/CAM TiBases
K
17
0384
Dentium NR Line CAD/CAM Abutments
K
16
3398
ATLANTIS suprastructures
K
17
0588
DESS Dental Smart Solutions
K
16
2633
Custom Bars
K
17
0100
CreoDent Solidex Customized Abutment and Screw
K
17
0356
Straumann Variobase Abutments
K
17
0354
Straumann Variobase Abutments
K
17
0044
Inclusive Titanium Abutments compatible with: MegaGen AnyRidge Implant System
K
17
0259
TruAbutment DS
K
16
1689
OSSTEM Implant System - Abutment
K
16
2734
CreoDent Solidex Customized Abutment
K
16
0670
ET US SS Prosthetic system
K
16
3350
Multibase Abutments EV and ATLANTIS Suprastructures
K
16
2028
PREMIUM - SHELTA Prosthetic Components
K
16
1416
Multi-unit Abutment Plus
K
16
1655
On1 Concept
K
16
2390
ET Hybrid Abutment
K
16
1713
Dentium CAD/CAM Abutments
K
16
0798
IPS e.max® Press Abutment Solutions for Viteo Base Ti
K
16
2004
PREMIUM Implant Systems SHELTA Implant Systems
K
15
3015
Transfer & Angled Abutment
K
16
1435
Temporary Snap Abutment
K
16
0786
RODO Abutment System
K
16
0132
Dental Implant Abutment OKTAGON Bone Level RC, Dental Implant Abutment OKTAGON Bone Level NC
K
16
0979
Inclusive Abutments
K
16
0519
Link Abutment for CEREC
K
16
1677
Straumann Sterile Healing Solution
K
16
0436
CreoDent Solidex Custom Abutment
K
16
0207
ATLANTIS ISUS Implant Suprastructures
K
16
0964
Neodent Implant System - Titanium Base for CEREC
K
16
0828
Dentium Implantium & SuperLine Prosthetics
K
16
0784
CAM Titanium Blanks
K
16
0626
ATLANTIS Abutment for HIOSSEN ET implant
K
16
1030
ATLANTIS Abutment for CONELOG implant
K
15
3509
GPS Angled Abutment
K
16
0382
OT EQUATOR
K
16
0483
Burn-out Cylinder and Angled Screw Abutments
K
16
0248
ArgenIS Titanium Abutments
K
16
0158
NobelProcera HT ML FCZ Implant Bridge and Framework
K
15
3645
VITA ENAMIC Implant Solutions (IS)
K
16
0244
VARIOunite
K
15
3036
NobelDesign Software
K
15
2559
TruAbutment DS
K
15
3624
Neodent Implant System
K
15
1608
4plus6Line Abutment System
K
15
3779
Abutment for Bridges
K
15
2845
Allied Biocompat Abutment for Nobel Replace Interface
K
15
1984
Thommen Milling Abutment for CAD/CAM
K
15
1789
LOCATOR F-Tx Attachment System
K
15
1590
Straumann RN Gold Abutment for Bridge
K
15
1439
ATLANTIS ISUS
K
15
1194
KLOCKNER DENTAL IMPLANT ABUTMENTS (II)
K
15
1039
ATLANTIS Abutment for NobelActive 3.0
K
15
1621
BioHorizons CAD/CAM Abutments
K
15
2509
CAMLOG and CONELOG Abutments for Screw-retained Restorations (ASR)
K
15
1295
Biodenta Customized Abutment - Titanium
K
14
2211
OT EQUATOR
K
15
1798
Inclusive Titanium Abutments compatible with: Straumann synOcta Implant System
K
15
1432
NaturalLine Abutment
K
15
0203
Medentika CAD/CAM Abutments
K
15
1169
OsteoReady ZircoSeal Abutments
K
15
0669
Neoss TiBase, Neoss CoCr Abutments (Mono and Multi)
K
15
1375
Inclusive Titanium Abutments compatible with: Hiossen HG Implant System
K
14
3515
Inclusive® Zirconia Abutments compatible with: Zimmer Screw-Vent, Biomet 3i Certain and Nobel Biocare NobelReplace Implants
K
15
1564
Telio CAD Abutment Solutions
K
15
0899
Straumann CARES Titanium Alloy (TAN) Abutment
K
14
3051
ArgenIS Titanium Abutments
K
15
1324
Straumann Variobase for CEREC
K
15
1247
NC Straumann Screw Retained Abutments
K
15
0814
Straumann Screw-Retained Abutment
K
15
1157
NC Straumann Variobase Abutment for Bars/Bridges, RC Straumann Variobase Abutment for Bars/Bridges, NNC Straumann Variobase Abutment for Bars/Bridges, RN Straumann Variobase Abutment for Bars/Bridges, WN Straumann Variobase Abutment for Bars/Bridges
K
14
1970
DIGITEK TITANIUM ABUTMENT
K
15
0295
LOCATOR RTx
K
15
0367
Neodent Implant System
K
15
0296
Biodenta Customized Abutment-Hybrid
K
14
3505
Zimmer Patient-Specific Abutment, Internal Hex, Titanium
K
15
0250
SternSnap Angled Attachment
K
15
0012
CreoDent Solidex Customized Abutment
K
14
3528
Zimmer Cast-to Gold Abutments for the 3.1mmD Dental Implant System
K
14
2167
MEDENTIKA ABUTMENT SYSTEM
K
14
3337
CONELOG Titanium base CAD/CAM
K
14
2572
Zimmer Zfx Abutment for Zimmer 3.1mmD Implant System
K
14
2890
Straumann Variobase Abutment NNC, Straumann Variobase Abutment RN, Straumann Variobase Abutment WN, Straumann Variobase Abutment NC, Straumann Variobase Abutment RC, IPS e.max CAD MO Coping, IPS e.max CAD LT Crown, IPS e.max CAD HT Crown, coron CoCr Single Unit
K
14
1923
INCLUSIVE TITANIUM ABUTMENTS, COMPATIBLE WITH DENTSPLY IMPLANTS ANKYLOS C/X
K
14
2407
Straight Stud Attachment
K
14
2118
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH: STRAUMANN BONE LEVEL, NOBEL BIOCARE BRANAE
K
14
2115
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH: ZIMMER, BIOMET 3I, AND NOBEL BIOCARE IMPLANT
K
14
1457
DENTIUM IMPLANTIUM AND SUPERLINE ABUTMENTS
K
14
1544
ZIMMER ZFX TITANIUM ABUTMENT FOR BIOMET 3I CERTAIN IMPLANT SYSTEM
K
14
1211
INCLUSIVE TITANIUM ABUTMENTS COMPATIBLE WITH STRAUMANN TISSUE LEVEL IMPLANTS
K
14
0600
SB ANCHOR
K
14
0507
HIOSSEN PROSTHETIC SYSTEM
K
14
0737
STRAUMANN CARES SCREW RETAINED BARS/BRIDGE
K
14
1871
Straumann Bone Level NC Angled Screw Retained Abutments
K
14
1120
ZIMMER ZFX TITANIUM ABUTMENT FOR STRAUMANN BONE LEVEL IMPLANT SYSTEM
K
13
2749
NOBELPROCERA OVERDENTURE BAR
K
13
3551
ZIMMER ZFX TITANIUM BASE ABUTMENT FOR TAPERED SCREWVENT IMPLANT SYSTEM
K
13
2214
ABUTMENT RP, ABUTMENT WP, BURN-OUT COPING, SCREWS, TITANIUM ADHESIVE BASE, ALLIGATOR ABUTMENT, SOLID ABUTMENT, RETENTIVE
K
13
1468
DENRACLE DENTAL ABUTMENT
K
13
4045
ZIMMER ZFX TITANIUM ABUTMENT, BASE ABUTMENT AND ABUTMENT BLANK FOR NOBELACTIVE IMPLANT SYSTEM
K
13
3421
STRAUMANN MAGELLAN(TM) ABUTMENT,PROTECTIVE CAP,TITANIUM COPINGS,GOLD CHOPINGS,BASAL SCREW
K
13
3791
ORA 0.4MM [S], ORA 1.0MM [S], ORA 2.0MM [S], ORA 3.0MM [S], ORA 4.0MM [S]
K
13
3377
NOBELPROCERA ANGULATED SCREW CHANNEL ABUTMENT REPLACE
K
13
0618
SFI-ANCHOR
K
13
3696
NEODENT IMPLANT SYSTEM
K
13
2814
SFI-BAR IMPLANT ABUTMENTS
K
13
2219
STRAUMANN(R) VARIOBASE(TM) ABUTMENT NNC, STRAUMANN(R) VARIOBASE(TM) ABUTMENT RN, STRAUMANN(R) VARIOBASE(TM) ABUTMENT WN,
K
13
2746
NOBELPROCERA ANGULATED SCREW CHANNEL ABUTMENT CONICAL CONNECTION
K
13
1644
ANKYLOS SYNCONE ABUTMENT 5(DEGREE)
K
13
2844
STRAUMANN CARES BONE LEVEL SCREW RETAINED BARS, STRAUMANN CARES BONE LEVEL SCREW RETAINED BRIDGES
K
13
0662
ET PROSTHETIC SYSTEM
K
13
2067
MULTI ANGLED ABUTMENT SYSTEM
K
13
2209
IPS E.MAX CAD ABUTMENT SOLUTIONS
K
12
2295
CORE 3D ABUTMENT SYSTEM FOR DIGITAL PROSTHETIC SOLUTIONS
K
13
1526
SFI-BAR
K
11
3738
CREODENT SOLIDEX CUSTOM ABUTMENT
K
13
1101
ITERO SOFTWARE
K
12
2988
KLOCKNER DENTAL IMPLANT ABUTMENTS
K
13
0183
SFI BAR ABUTMENTS
K
12
2424
ISUS IMPLANT SUPRASTRUCTURES
K
13
0408
ERA MICRO 23 FEMALE ABUTMENT, ERA MICRO 30 FEMALE ABUTMENT
K
13
0808
STRAUMANN HEALING ABUTMENTS, HEALING CAPS, CLOSURE SCREWS
K
12
3627
ET SMARTFIT ABUTMENT
K
13
0310
CERTAIN BELLATEK PROVISIONAL ABUTMENTS
K
12
0954
NOBELPROCERA PEEK ABUTMENTS
K
12
3491
BIODENTA DENTAL IMPLANT SYSTEM - MULTI-USE ABUTMENT
K
12
2559
BIODENTA DENTAL IMPLANT SYSTEM - ABUTMENTS
K
13
0216
ATLANTIS STRAUMANN BONE LEVEL ABUTMENT
K
12
3755
MULTI ANGLED ABUTMENT
K
12
4008
IPS E. MAX PRESS ABUTMENT SOLUTIONS FOR NOBEL BIOCARE
K
12
2602
NOBELPROCERA TI ABUTMENT CAMLOG PLATFORMS
K
11
3816
GC AADVA ABUTMENT- ZIRCONIUM-BO AC BH SV
K
12
1810
OSSEOSPEED ANGLED ABUTMENT EV
K
12
0822
STRAUMANN CARES VARIOBASE ABUTMENT NNC, STRAUMANN CARES VARIOBASE ABUTMENT RN, STRAUMANN CARES VARIOBASE ABUTMENT WN, ST
K
12
1117
NDX ABUTMENTS
K
12
2268
ANGLED XIVE MP ABUTMENT, ANGLED ANKYLOS
K
12
1843
NP-CAST ABUTMENT SYSTEM
K
12
1391
INCLUSIVE TITANIUM ABUTMENTS FOR CAMLOG SCREW-LINE IMPLANTS
K
12
0858
IMPLANT BAR
K
12
0873
ZIMMER ZFX ABUTMENT FOR NOBEL REPLACE IMPLANT SYSTEM
K
12
2192
NC TEMPORARY ABUTMENT, CAD-TEMP, PMMA RC TEMPORARY ABUTMENT, CAD-TEMP, PMMA RN TEMPORARY ABUTMENT, CAD-TEMP, PMMA WN TEM
K
12
1709
ZFX DENTAL CAD SYSTEM
K
12
0053
IPS E.MAX PRESS - ABUTMENT SOLUTIONS
K
12
1688
MULTI-UNIT ABUTMENTS WITH ANGULATIONS 17 AND 30 FOR TAPERED IMPLANT SYSTEM
K
12
0776
ABUTMENT FOR COMPETITIVE IMPLANT NOBEL ACTIVE CONNECTION
K
12
1334
VARIOECO
K
11
2787
KERATOR
K
12
0338
ATLANTIS IN ZIRCONIA FOR DENTSPLY ANKYLOS IMPLANT, ATLANTIS LATER ABUTMENT IN ZIRCONIA
K
11
3003
ATLANTIS(TM) ABUTMENT AND ATLANTIS(TM) CROWN ABUTMENT FOR KEYSTONE GENESIS IMPLANT, ATLANTIS GEMINI(TM) ABUTMENT...
K
11
1935
TI-BASE ABUTMENT, 1 CONNECT ABUTMENT
K
11
1421
SIRONA DENTAL CAD/CAM SYSTEM
K
11
2099
CONTOUR HEALER
K
11
2333
LRT ATTACHMENT
K
11
3606
NNC GOLD ABUTMENT FOR BRIDGES
K
11
2045
SIMPLELINE II ABUTMENT SYSTEM
K
11
3092
ZIMMER CONTOUR PROVISIONAL COPING
K
11
3410
NNC SOLID ABUTMENT NNC TEMPORARY COPING FOR COLID ABUTMENT NNC TEMPORARY CAP FOR COLID ABUTMENT
K
11
2730
ABUTMENT FOR COMPETITIVE IMPLANT STRAUMANN BONE LEVEL CONNECTION
K
11
3283
NNC CEMENTABLE ABUTMENT STRAIGHT,15 DEGREE ANGLE, TYPE A ,15 DEGREE ANGLE, TYPE B,NNC BASAL SCREW CEMENTABLE ABUTMENTS
K
11
1853
ANGLED TAPERED ABUTMENT
K
11
2138
ATLANTIS ABUTMENT IN ZIRCONIA FOR ASTRA TECH OSSEOSPEED PLUS IMPLANT
K
11
2280
STRAUMANN CARES SCREW-RETAINED BRIDGE TITANIUM, STRAUMANN CARES DOLDER BAR TITANIUM
K
11
1984
SPI VARIO ANGLED ABUTMENT
K
10
3291
BIOHORIZONS LASER-LOK ABUTMENTS FOR NOBEL BIOCARE
K
10
3691
BIOHORIZONS ABUTMENTS FOR ZIMMER
K
11
2259
NOBELACTIVE 3.0 GOLDADAPT ABUTMENTS
K
11
0308
PROSTHETIC SYSTEM
K
11
1390
SFI-BAR (R) IMPLANT ADAPTER SPI (R) ELEMENT PF 0 4.0 / H 3.0 / H 4.0 / H 5.0 / H 6.0, SFI-BAR (R) IMPLANT ADAPTER STRA..
K
11
0565
ABUTMENTS FOR COMPETITIVE IMPLANT SYSTEMS-NOBEL REPLACE
K
11
0580
NARROW CONNECTION STRAUMANN ANATOMIC IPS E.MAX ABUTMENTS
K
11
1852
ANODIZED HEALING COLLAR
K
11
1199
INTRA-LOCK DENTAL IMPLANTS WITH BLOSSOM 3.4MM IMPLANT ANGLED ABUTMENTS
K
11
0778
BIODENTA CUSTOMIZED ABUTMENT
K
10
3234
GC AADVA BO AC ABUTMENTS
K
11
1581
15 ESTHETIC ABUTMENT NOBELACTIVE 03.0 1.5MM, 15 ESTHETIC ABUTMENT NOBELACTIVE 03.0 3MM, 15 ESTHETIC ABUTMENT NOBELACTIVE
K
10
1005
ASTRA TECH IMPLANT SYSTEM, NEW COMPONENT
K
11
0171
NOBELPROCERA ZI ABUTMENT THOMMEN PLATFORMS
K
11
0640
ATLANTIS ABUTMENT FOR CAMLOG IMPLANT, DUPLICATE ABUTMENT, LATER ABUTMENT
K
11
0356
ATLANTIS CROWN ABUTMENT, ATLANTIS GEMINI +(TM) ABUTMENT
K
10
2804
SPI TITANIUM BASE FOR CAD/CAM
K
10
3759
ATLANTIS ABUTMENT IN ZIRCONIA FOR OSSEOSPEED TX PROFILE IMPLANT
K
10
2467
UTA AND UHA
K
10
3339
TDS ABUTMENT FOR FRIADENT XIVE
K
10
1608
BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS-ENCODE ABUTMENTS
K
10
1607
BIOMET 3I PATIENT SPECIFIC DENTAL ABUTMENTS - ENCODE ABUTMENTS
K
10
3280
BHDENTAL IMPLANT SYSTEM
K
10
3020
ATLANTIS ABUTMENT FOR KEYSTONE IMPLANT, ATLANTIS GEMINI ABUTMENT
K
10
1890
BALL ABUTMENT SYSTEM
K
10
3252
CAMLOG VARIO SR ABUTMENTS
K
10
0993
INCLUSIVE TITANIUM ABUTMENTS FOR ASTRA TECH OSSEOSPEED IMPLANTS
K
10
1465
STRAUMANN CARES BRIDGE; STRAUMANN CARES DOLDER BAR
K
10
2382
SFI-BAR IMPLANT ADAPTER STRAUMANN, SFI-BAR IMPLANT ADAPTER FOR NEOSS IMPLANT
K
10
2209
ENCODE PATIENT SPECIFIC ABUTMENT
K
10
1582
CAM STRUCTSURE BARS
K
10
0152
SIRONA CAD/CAM SYSTEM
K
10
0356
TDS PRECISION DENTAL BAR
K
10
0985
BIOHORIZONS SIMPLE SOLUTIONS WITH LASER-LOK
K
10
1714
NOBELPROCERA TI ABUTMENT THOMMEN PLATFORMS
K
10
1068
ACCUFIT DENTAL IMPLANT ABUTMENTS & SCREWS
K
10
1798
SPI VARIOMULTI ANGLED ABUTMENT
K
10
0245
HS/HG PROSTHETIC SYSTEM
K
10
1004
ATLANTIS ABUTMENT FOR DENTSPLY ANKYLOS IMPLANT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI + ABUTMENT
K
09
3643
MULTI- UNIT ABUTMENTS FOR STRAUMANN AND ASTRA TECH IMPLANT SYSTEMS
K
09
0081
TALLADIUM INTERNATIONAL IMPLANTOLOGY ABUTMENTS
K
09
3975
SIMPLER TOADSTOOL ABUTMENT, MODEL S19000-S19009
K
09
3780
ATLANTIS ABUTMENT FOR DENTSPLY IMPLANT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI + ABUTMENT
K
09
2857
VERICORE ABUTMENT IN TITANIUM FOR IMPLANT SYSTEMS
K
08
3876
SFI-BAR SYSTEM COMPLETE 2-IMPLANT AND 4-IMPLANT
K
09
3483
ATLANTIS ABUTMENT FOR NOBEL BIOCARE ACTIVE IMPLANT, ATLANTIS GEMINI ABUTMENT, GEMINI + ABUTMENT
K
09
1701
STRAUMANN MODIFIED DENTAL ABUTMENT
K
09
3113
ETKON ES1, MODEL 019.0001, ETKON VISUAL, STRAUMANN CADCAM ABUTMENT
K
09
2814
STRAUMANN DENTAL ABUTMENTS
K
09
2341
LOW PROFILE ABUTMENTS - INTERNAL AND EXTERNAL CONNECTION
K
09
2377
PLASTIC TEMPORARY ABUTMENTS, MODELS: PT341S, PT344S, PT341A, PT344A, PT451S, PT454S, PT451A, PT454A, PT561S, PT564S
K
09
2403
TI PREPABLE ABUTMENT, MODEL 1618, 1619, 1620
K
09
1848
NOBEL/PROCERA IMPLANT BRIDGE
K
09
1907
NOBELPROCERA IMPLANT BRIDGE ZIRCONIA
K
09
1920
ATLANTIS ABUTMENT IN ZIRCONIA, ATLANTIS GEMINI ABUTMENT FOR NOBEL REPLACE IMPLANTS, ATLANTIS GEMINI + ABUTMENT FOR NOBEL
K
09
2248
SPI CUSTOMIZABLE GINGIVA FORMER
K
09
1904
NOBELPROCERA ZI ABUTMENT
K
09
1756
NOBELPROCERA TI ABUTMENT
K
09
1693
TDS ZIRCONIA ABUTMENT FOR NOBEL BIOCARE BRANEMARK
K
09
1392
TDS TITANIUM ABUTMENT FOR NOBEL BIOCARE BRANEMARK
K
09
0976
VERICORE ABUTMENT IN ZIRCONIA FOR IMPLANT SYSTEMS
K
09
1026
TDS ABUTMENT FOR NOBEL BIOCARE REPLACE
K
09
0347
CAMLOG ABUTMENTS PS
K
09
0397
XPI ANGLED ABUTMENTS
K
09
0069
PROCERA IMPLANT BRIDGE OVERDENTURE
K
08
3480
INCLUSIVE ZIRCONIA ABUTMENT BLANKS
K
08
3871
ATLANTIS STRAUMANN BONE LEVEL ABUTMENT, ATLANTIS GEMINI STRAUMANN BONE LEVEL ABUTMENT, ATLANTIS GEMINI + STRAUMANN BONE
K
09
0723
HEX-LOCK SHORT ABUTMENT, MODEL SA341, SA342, SA451, SA452, SA561, SA562 SHORT HEALING CAP, MODEL SAHEAL4, SAHEAL5,
K
09
0153
SPI VARIOMULTI ANGLED ABUTMENT
K
08
3192
INCLUSIVE TITANIUM ABUTMENT BLANKS
K
08
1851
NEOSS ACCESS ABUTMENTS
K
08
3324
LOCATOR IMPLANT ANCHOR ATTACHMENT SYSTEM
K
08
3544
KAT IMPLANT SYSTEM
K
08
1396
SWISSPLANT DENTAL IMPLANT SYSTEM
K
08
1101
SPECTRA-SYSTEM ABUTMENTS 2008
K
08
3474
ZIMMER ANGLED CONTOUR ZIRCONIA ABUTMENT
K
08
1786
ZIOCERA & CONVERTIBLE SYSTEM
K
08
1460
TDS ABUTMENT
K
08
2299
VERICORE IMPLANT ABUTMENTS
K
08
3100
GOLDADAPT NON-ENGAGING NOBELACTIVE NP & RP, GOLDADAPT ENGAGING NOBELACTIVE NP & RP
K
08
3141
SIMPACT ENDOSSEOUS DENTAL IMPLANT SYSTEM
K
08
2545
STRAUMANN NN CARES TITANIUM AND CERAMIC ABUTMENTS
K
08
1666
ATLANTIS, ATLANTIS GEMINI, ATLANTIS GEMINI+ ABUTMENTS FOR ASTRA OSSEOSPEED 3.0 IMPLANTS
K
08
2764
STRAUMANN WN CARES TITANIUM ABUTMENT
K
08
0164
ZIMMER PATIENT-SPECIFIC CERAMIC ABUTMENT
K
08
1575
HU/HS/HG PROSTHETIC SYSTEM
K
08
1157
ACCUFRAME
K
08
0864
CAM STRUCTSURE PRECISION MILLED BARS
K
08
1186
CONCAVE RN HEALING CAP
K
08
0598
MINI DRIVE-LOCK DENTAL IMPLANT SYSTEM PROSTHETICS
K
07
3217
INCLUSIVE IMPLANT ABUTMENTS
K
08
0397
AMERICAN DENTAL IMPLANT ABUTMENT SYSTEM
K
08
1005
P.004 NC CARES TITANIUM AND CERAMIC ABUTMENTS
K
08
0239
P.004 ABUTMENTS, P.004 TEMPORARY COPINGS, P.004 PROTECTIVE CAPS, P.004 PERMANENT COPINGS
K
07
2730
FRIADENT CERCON AND ANKYLOS CERCON BALANCE ABUTMENTS
K
08
0286
CEMENTABLE ABUNTMENTS; TEMPORARY COPINGS; PROTECTIVE CAPS
K
07
3345
CERTAIN CONTOURED MARGIN CERAMIC ABUTMENT
K
07
3553
CAMLOG IMPLANT SYSTEM ABUTMENTS
K
07
3540
ATLANTIS ABUTMENT IN ZIRCONIA FOR BIOHORIZONS IMPLANT
K
07
2055
LAVA FRAME, LAVA FRAME SHADE
K
07
2129
NOBELACTIVE ZIRCONIA ABUTMENT
K
07
2856
SPI VARIOMULTI ABUTMENT
K
07
3258
ATLANTIS ABUTMENT FOR BIOHORIZON IMPLANTS, ATLANTIS GEMINI ABUTMENT FOR BIOHORIZON IMPLANTS, ATLANTIS GEMINI + ABUTMENT
K
07
2100
GC AADVA ABUTMENT
K
07
3073
ANKYLOS TEMPORARY ABUTMENT BALANCE
K
07
3628
SYNOCTA ABUTMENTS
K
07
2570
NOBELACTIVE MULTI UNIT ABUTMENT
K
07
2642
BIOMET 3I DENTAL ABUTMENTS AND RESTORATIVE COMPONENTS
K
07
3141
SPI ART ABUTMENT
K
07
2878
MODIFICATION TO: LOCATOR IMPLANT ANCHOR
K
07
0228
IMPLANTIUM PROSTHETICS
K
07
3032
PRIMACONNEX SD ESTHETIC CONTOUR ZI ABUTMENTS
K
07
2483
ATLANTIS ABUTMENT IN ZIRCONIA FOR 3I CERTAIN MICROAMINI IMPLANTS, GEMINI ABUTMENT IN ZIRCONIA FOR ASTRA IMPLANTS
K
07
2241
PRIMACONNEX CAD/CAM ABUTMENT SYSTEM
K
07
1838
NEOSS VARIOUS TITANIUM ABUTMENTS
K
07
1888
STRAUMANN P.004 RC GOLD ABUTMENT FOR BRIDGES
K
07
2679
P.004 ABUTMENTS
K
07
2572
PRIMACONNEX RD AND WD ESTHETIC CONTOUR ZI ABUTMENTS
K
07
1946
ATLANTIS, GEMINI AND GEMINI+ ABUTMENTS IN ZIRCONIA FOR ASTRA IMPLANTS
K
07
2624
ASTRA TECH IMPLANT SYSTEM, NEW COMPONENT
K
07
2497
P.004 NC GOLD ABUTMENT FOR CROWNS
K
07
1919
P.004 ABUTMENTS
K
07
1357
P.004 NC ANATOMIC ABUTMENTS
K
07
0478
P.004 RC TEMPORARY ABUTMENT, P.004 TEMPORARY HEALING ABUTMENT (CAP)
K
07
1453
SPI EASY 4.0 ABUTMENT
K
07
2151
P.004 RC CARES TITANIUM AND CERAMIC ABUTMENTS
K
07
0549
STRAUMANN P.004 RC GOLD ABUTMENT
K
07
1551
QUICKBRIDGE TM CYLINDER AND CAP
K
07
2071
STRAUMANN P.004 CEMENTABLE ABUTMENTS, TEMPORARY COPINGS AND PROTECTIVE CAPS
K
07
1213
CAMLOG LOGFIT PROSTHETIC SYSTEM
K
07
1585
P.004 HEALING ABUTMENTS AND CLOSURE SCREWS
K
07
0744
NARROW NECK TEMPORARY COPING
K
06
3768
TITANIUM SCALLOPED ABUTMENT
K
07
0833
ATLANTIS ABUTMENT FOR ASTRA IMPLANT
K
07
0533
BTI ENDOSSEOUS DENTAL IMPLANT ANGLED ABUTMENTS
K
06
3106
REVOIS IMPLANT SYSTEM
K
07
0562
EZ PLUS IMPLANT SYSTEM
K
06
3789
WN SYNOCTA GOLD ABUTMENT
K
06
1277
STRAUMANN COMPUTER AIDED RESTORATION SERVICE (C.A.R.E.S.) CERAMIC COPING
K
06
3403
CONICAL ANGLED ABUTMENT
K
06
3734
ATLANTIS ABUTMENT IN ZIRCONIA FOR 3I CERTAIN INTERFACE
K
06
2197
ATLANTIS ABUTMENT FOR 3I CERTAIN MICRO MINI; GEMINI AND GEMINI+ ABUTMENT
K
06
3592
ADAPTER PS RP-NP, 34551, ADAPTER PS WP-RP,34552, ABUTMENT SCREW PS RP-NP, 34553, ABUTMENT SCREW PS WP-RP, 34554
K
06
2069
ATLANTIS ABUTMENT FOR 3I MICROMINI IMPLANT
K
06
2277
ATLANTIS ABUTMENT IN ZIRCONIA FOR NOBEL BIOCARE REPLACE
K
06
2749
SBF 15 ESTHETIC ABUTMENT 1MM NP, MODEL 33699, SFB 15 ESTHETIC ABUTMENT 1MM RP, MODEL 33701, CFB 15 ESTHETIC ABUTMENT 2MM
K
06
1567
BIOHORIZONS CERAMIC ABUTMENT
K
06
2493
LAVA SOFTWARE
K
06
2876
PRIMACONNEX CERAMIC ABUTMENTS
K
06
1847
ZIMMER CONTOUR CERAMIC ABUTMENT, MODELS ZRA341S, ZRA342S, KRA451S, ZRA452S
K
06
1529
PROCERA ZIRCONIA ABUTMENT FOR CAMLOG IMPLANT SYSTEM
K
06
1478
PROCERA TITANIUM ABUTMENT FOR ASTRATECH AND CAMLOG IMPLANT SYSTEMS
K
06
1477
MULTI-UNIT ABUTMENTS FOR ASTRATECH, CAMLOG AND ANKYLOS IMPLANT SYSTEMS
K
06
1807
SPI ART ABUTMENTS
K
05
3654
ATLANTIS ABUTMENT FOR NOBEL REPLACE INTERFACE
K
05
2957
IMPLANTIUM PROSTHETICS
K
06
1969
PREFORMANCE POSTS AND TEMPORARY CYLINDERS
K
05
3373
ATLANTIS ABUTMENT FOR ZIMMER INTERFACE
K
06
1043
ZIMMER CONTOUR RESTORATIVE SYSTEM
K
06
0063
LEGACY ABUTMENT SYSTEM
K
06
0880
ZIMMER DENTAL ONE PIECE TAPERED ABUTMENT, MODELS TAC1, TACW1, TA5C1
K
06
1177
PROVIDE TEMPORARY CYLINDER
K
05
3450
ATLANTIS ABUTMENT FOR ZIMMER INTERFACE
K
06
0291
PREFORMANCE TEMPORARY CYLINDER
K
05
3125
PROCERA BRIDGE ZIRCONIA
K
05
3068
PROCERA BRIDGE LAMINATE, MODEL 40-4002
K
05
3050
PROCERA BRIDGE ALUMINA
K
05
2823
IMPLANTIUM ABUTMENTS
K
05
1636
CAMLOG DENTAL IMPLANT ABUTMENTS, HEALING CAPS, AND ACCESSORIES
K
05
3099
BIOHORIZONS PLASTIC TEMPORARY ABUTMENTS
K
05
3602
PROCERA SOFTWARE, MODEL 33145
K
05
3170
PREFORMANCE POSTS
K
05
3091
PROCERA IMPLANT BRIDGE ZIRCONIA
K
05
3643
STAGE- 1 TEMPORARY/HEALING CAP, MODEL 42021-42026
K
05
2272
STRAUMANN COMPUTER AIDED RESTORATION SERVICE
K
05
2885
ZYGOMA 17 ABUTMENT MULTI-UNIT RP 2MM, MODEL 29314; ZYGOMA 17 ABUTMENT MULTI-UNIT RP 3MM, MODEL 29315
K
05
2648
MODIFICATION TO 3I PATIENT-SPECIFIC DENTAL ABUTMENTS AND OVERDENTURE BARS
K
05
1501
ZIRACE
K
05
2070
ATLANTIS ABUTMENT IN ZIRCONIA, ATLANTIS GEMINI ABUTMENT IN ZIRCONIA, ATLANTIS GEMEINI + ABUTMENT IN ZIRCONIA
K
05
2600
ZIMMER DENTAL HEX-LOCK PREPARED ABUTMENT (STRAIGHT & ANGLED)
K
05
1527
SPI EASY TEMPORARY CAP
K
05
1652
ATLANTIS ABUTMENT, ATLANTIS GEMINI ABUTMENT, ATLANTIS GEMINI+ ABUTMENT
K
05
1011
ENDOSSEOUS DENTAL IMPLANT ABUTMENT
K
04
3428
RELIADENT DENTAL IMPLANT SYSTEM
K
05
1717
RN SYNOCTA TEMPORARY MESO ABUTMENT
K
05
0444
NOBELREPLACE ADAPTER, MODEL 32412
K
05
0208
FRIADENT ESTHETICAP
K
05
0641
ZYGOMA TIUNITE
K
04
2715
TITAN DENTAL IMPLANT ATTACHMENT
K
05
0052
ATLANTIS ABUTMENT FOR STRAUMANN INTERFACE
K
04
3190
SCALLOPED ENDOPORE ENDOSSEOUS DENTAL IMPLANT SYSTEM
K
04
2466
X-2 IMPLANT ABUTMENT; BAR MALE; DISTAL EXTENSION MALE
K
04
3042
PROCERA IMPLANT BRIDGE, MODELS 15-1001, 15-1002, 15-1051, 15-1052
K
04
2658
PROCERA ABUTMENT BRANEMARK, MODELS 10-4001, 10-4004, 10-5001, 10-5004, 10-6001, 10-6004
K
04
1070
STRAUMANN TEMPORARY COPING
K
04
1275
PROCERA ABUTMENT OCTAGON
K
04
1236
PROCERA IMPLANT BRIDGE, MODELS 15-1001, 15-1002, 15-1051, 15-1052
K
04
1295
RN SYNOCTA UCLA GOLD ABUTMENT FOR THE STRAUMANN DENTAL IMPLANT
K
04
0573
NOBEL BIOCARE PERMANENT CENTRIC POST, MODELS 31234, 31235, 31236
K
03
4035
3I PATIENT-SPECIFIC OVERDENTURE BAR
K
04
0205
INTRA-LOCK INTERNATIONAL ANGLED PROSTHETIC ABUTMENTS
K
04
0539
ELLIPTIC MATRIX
K
03
3724
NOBEL BIOCARE CENTRIC POST, MODELS 31234, 31235 AND 31236
K
03
3346
SPI EASY DENTAL IMPLANT PROTECTIVE CAP
K
03
3243
ITI SYNOCTA MESO ABUTMENTS
K
03
2498
DENTAL IMPLANT COPING (PROSTHETIC ACCESSORIES TO THE ITI DENTAL IMPLANT SYSTEM)
K
03
2448
ALTATEC CERAMIC ABUTMENT
K
03
1747
SPI DENTAL IMPLANT ABUTMENTS
K
03
1719
ESTHETIC ZIRCONIA ABUTMENT
K
02
3645
SPI EASY DENTAL IMPLANT ABUTMENT
K
02
3631
ASTRA TECH DENTAL IMPLANTS-CERAMIC ABUTMENTS
K
02
2795
MODIFICATION TO THE MAESTRO SYSTEM
K
02
1460
OCO DENTAL IMPLANT
K
01
4175
SULZER DENTAL CERAMIC SYSTEM-HEXLOCK
K
97
4150
PROCERA PREPARABLE ABUTMENT SYSTEM
K
97
2475
AURADAPT AUBTMENT SYSTEM
K
97
1706
TIADAPT ABUTMENT SYSTEM
K
97
0073
BIO-ESTHETIC INDIRECT ABUTMENT
K
96
1736
17 ANGULATED ABUTMENT
K
96
1728
MIRUSCONE ABUTMENT SYSTEM
K
92
5349
ONE SYSTEM TAPERED TITANIUM ABUTMENTS
K
92
5779
BRANEMARK SYSTEM TITANIUM HEALING ABUTMENTS
K
92
5769
BRANEMARK SYSTEM ABUTMENTS COMPLETE
NKJ
Cushion, Pad, Denture, Wax Impregnated Cotton, Over The Counter
NME
Bur, Diamond Coated, Reprocessed
NOF
System, Optical Impression, Computer Assisted Design And Manufacturing (Cad/Cam) Of Dental Restorations
NPK
Barrier, Synthetic, Intraoral
NPL
Barrier, Animal Source, Intraoral
NPM
Bone Grafting Material, Animal Source
NPZ
Bone Grafting Material, Dental, With Biologic Component
NQA
Biologic Material, Dental
NRQ
Blade-Form Endosseous Dental Implant
NUN
Bone Grafting Material, Human Source
NUX
Cleanser, Denture, Prescription
NYD
Endodontic Kit
OAT
Implant, Endosseous, Orthodontic
NYE
Fixture Mount Kit
OFW
Restorative Instrument And Component Tray
OFY
Dental Implant Surgical Tray
OIV
Dental Amalgam
PHR
Diammine Silver Fluoride Dental Hypersensitivity Varnish
PME
External Cleaning Solution
PNP
Dental Abutment Design Software For Dental Laboratory
POW
Crown And Bridge, Long-Term Temporary, Resin
PZY
Additively Manufactured, Preformed, Resin Denture Tooth
QJK
Intraoral Camera
QRQ
Non-Irrigation Endosseous Dental Implant Drill Bits
Surgical Devices
Therapeutic Devices
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
DE
/
prosthetic-devices
/
NHA
/
K080397
View Source
AMERICAN DENTAL IMPLANT ABUTMENT SYSTEM
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K080397
510(k) Type
Traditional
Applicant
AMERICAN DENTAL IMPLANT CORPORATION
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/6/2008
Days to Decision
83 days
Submission Type
Statement