Quantum PureFlow Standard Heat Exchanger, Quantum PureFlow Cardioplegia Heat Exchanger

K212688 · Qura S.R.L · DTR · Jan 10, 2022 · Cardiovascular

Device Facts

Record IDK212688
Device NameQuantum PureFlow Standard Heat Exchanger, Quantum PureFlow Cardioplegia Heat Exchanger
ApplicantQura S.R.L
Product CodeDTR · Cardiovascular
Decision DateJan 10, 2022
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.4240
Device ClassClass 2
AttributesTherapeutic

Intended Use

Quantum PureFlow Standard Heat Exchanger: The Quantum PureFlow Standard Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration. Devices are intended for adult patients. Quantum PureFlow Cardioplegia Heat Exchanger: The Quantum PureFlow Cardioplegia Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool cardioplegic solution, to remove air and to monitor the temperature during routine cardiopulmonary bypass (CPB) procedures up to 6 hours duration. Any blood to be treated must contain anticoagulant. Contact with cardioplegic solution for longer than this period is not permitted. Devices are intended for adult patients.

Device Story

Quantum PureFlow Heat Exchangers manage blood or cardioplegic solution temperature during cardiopulmonary bypass (CPB) procedures. Devices connect to external heater/cooler systems using water as heat transfer fluid. Standard Heat Exchanger (HX-S) maintains/rewarms blood; Cardioplegia Heat Exchanger (HX-C) heats/cools cardioplegic solution, removes air, and monitors temperature. Used in surgical settings by clinical staff. Output allows precise thermal regulation of patient/myocardium during surgery. Benefits include maintenance of normothermic conditions or myocardial arrest, supporting patient safety during bypass.

Clinical Evidence

No clinical data included. Substantial equivalence supported by bench testing only, including biocompatibility (ISO 10993-1), mechanical/performance verification (ISO 7199), sterilization validation (ISO 11135), and packaging validation (ISO 11607-1).

Technological Characteristics

Heat exchangers for CPB circuits. Materials: biocompatible per ISO 10993-1. Energy source: external heater/cooler system (water-based heat transfer). Sterilization: EtO (ISO 11135). Form factor: integrated into CPB circuit. Connectivity: fluid-path integration with heater/cooler systems.

Indications for Use

Indicated for adult patients undergoing cardiopulmonary bypass (CPB) procedures up to 6 hours. Standard Heat Exchanger: heating/cooling blood. Cardioplegia Heat Exchanger: heating/cooling cardioplegic solution, air removal, and temperature monitoring. Contraindications: blood without anticoagulant; cardioplegic solution contact exceeding 6 hours.

Regulatory Classification

Identification

A cardiopulmonary bypass heat exchanger is a device, consisting of a heat exchange system used in extracorporeal circulation to warm or cool the blood or perfusion fluid flowing through the device.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logos of the Department of Health and Human Services and the Food and Drug Administration (FDA). The Department of Health and Human Services logo is on the left, and the FDA logo is on the right. The FDA logo includes the letters "FDA" in a blue square, followed by the words "U.S. FOOD & DRUG ADMINISTRATION" in blue text. January 10, 2022 Qura S.r.1. Raffaella Tommasini QA&RA Director Via di Mezzo, 23 Mirandola, Modena 41037 Italy Re: K212688 Trade/Device Name: Quantum PureFlow Standard Heat Exchanger Quantum PureFlow Cardioplegia Heat Exchanger Regulation Number: 21 CFR 870.4240 Regulation Name: Cardiopulmonary Bypass Heat Exchanger Regulatory Class: Class II Product Code: DTR Dated: November 22, 2021 Received: December 10, 2021 Dear Raffaella Tommasini: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database located at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's {1}------------------------------------------------ requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803) for devices or postmarketing safety reporting (21 CFR 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reportingcombination-products); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-device-safety/medical-device-reportingmdr-how-report-medical-device-problems. For comprehensive regulatory information about mediation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medicaldevices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-device-advice-comprehensive-regulatoryassistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Nicole Gillette Assistant Director DHT2B: Division of Circulatory Support, Structural and Vascular Devices OHT2: Office of Cardiovascular Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K212688 ### Device Name Quantum PureFlow Cardioplegia Heat Exchanger # Indications for Use (Describe) The Quantum PureFlow Cardioplegia Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool cardioplegic solution, to remove air and to monitor the temperature cardiopulmonary bypass (CPB) procedures up to 6 hours duration. Any blood to be treated must contain anticoagulant. Contact with cardioplegic solution for longer than this period is not permitted. Devices are intended for adult patients. Type of Use (Select one or both, as applicable) |X Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) # CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. # *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ # Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 06/30/2023 See PRA Statement below. 510(k) Number (if known) K212688 ### Device Name Quantum PureFlow Standard Heat Exchanger Indications for Use (Describe) The Quantum PureFlow Standard Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat cool blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration. Devices are intended for adult patients. Type of Use (Select one or both, as applicable) |X Prescription Use (Part 21 CFR 801 Subpart D) Over-The-Counter Use (21 CFR 801 Subpart C) # CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. # *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4}------------------------------------------------ Image /page/4/Picture/0 description: The image is a logo for Qura Advanced Medical Solutions. The logo features a stylized human figure with arms outstretched, enclosed within a curved shape. The text "QURA" is prominently displayed in a bold, sans-serif font, with the words "advanced medical solutions" written in a smaller font size underneath. #### Section 5.0 510(K) SUMMARY #### l. SUBMITTER | Submitter Name: | Qura S.r.l. | |------------------------|---------------------------------------------| | Submitter Address: | Via di Mezzo, 23 41037 Mirandola (MO) Italy | | Contact Person: | Raffaella Tommasini, QA&RA Director | | Phone: | +39 0535 1803050 | | e-mail: | raffaella.tommasini@quramed.com | | Fax: | +39 0535 1803051 | | Date Summary Prepared: | November 22nd, 2021 | #### II. DEVICES | Proprietary Name: | Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow<br>Cardioplegia Heat Exchanger | |----------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------| | Common Name: | Standard Heat Exchanger<br>Cardioplegia Heat Exchanger | | Classification Name: | Cardiopulmonary bypass heat exchanger | | Regulatory Class: | II | | Product Code: | DTR | | Panel: | Cardiovascular Devices, Office of Health Technology 2 (OHT2) / Division of<br>Health Technology 2 B (Circulatory Support, Structural and Vascular Devices) | | 510(k) Number: | K212688 | #### lll. PREDICATE DEVICES - Primary Predicate Device for Quantum PureFlow Standard Heat Exchangers Quantum PureFlow Standard Heat Exchangers are being compared to its primary predicate device: | Trade Name: | Apex Hp M Adult Hollow Fiber Membrane Oxygenator | |--------------------------------|--------------------------------------------------| | Registered Establishment Name: | SORIN GROUP ITALIA S.R.L. | | Regulation Number: | 21 CFR 870.4350 | | Regulation Name: | Cardiopulmonary bypass oxygenator | | Regulatory Class: | II | | Product Code: | DTZ | | 510(k) Number: | K092895 | {5}------------------------------------------------ Image /page/5/Picture/0 description: The image is a logo for Qura Advanced Medical Solutions. The logo features a stylized human figure with arms outstretched, enclosed within a circular shape. To the right of the figure, the word "QURA" is written in a bold, sans-serif font. Below "QURA", the words "advanced medical solutions" are written in a smaller, lighter font. To support other flow variants (Medium and Low Flow) of Quantum PureFlow Standard Heat Exchanger, two reference devices are also being used: - Sorin Group Italia D101 Kids Infant Hollow Fiber Membrane Oxygenator with integrated Hardshell Cardiotomy/Venous Reservoir Trade Name: D101 Kids Infant Hollow Fiber Membrane Oxygenator With Integrated Hardshell Cardiotomy/Venous Reservoir | Registered Establishment Name: | SORIN GROUP ITALIA S.R.L. | |--------------------------------|-----------------------------------| | Regulation Number: | 21 CFR 870.4350 | | Regulation Name: | Cardiopulmonary bypass oxygenator | | Regulatory Class: | II | | Product Code: | DTZ | | 510(k) Number: | K072091 | - Sorin Group Italia D100 L001 Ph.I.S.I.O D 100 L001 Ph.I.S.I.O Newborn Hollow Fiber Oxygenator with Integrated Hardshell Cardiotomy/Venous Reservoir with phosphorylcholine coating (hereafter D 100 Ph.I.S.I.O) Trade Name: D 100 L001 Ph.I.S.I.O: D 100 L001 Ph.I.S.I.O Newborn Hollow Fiber Oxygenator with Integrated Hardshell Cardiotomy Venous Reservoir with phosphorylcholine coating (hereafter referred to as D 100 Ph.I.S.I.O.) Registered Establishment Name: SORIN GROUP ITALIA S.R.L. | Regulation Number: | 21 CFR 870.4350 | |--------------------|-----------------------------------| | Regulation Name: | Cardiopulmonary bypass oxygenator | | Regulatory Class: | II | | Product Code: | DTZ | | 510(k) Number: | K061031 | #### Predicate Device for Quantum PureFlow Cardioplegia Heat Exchanger (High Flow and Low Flow variants): - | Trade Name: | CSC14 Blood Cardioplegia System | |--------------------------------|-----------------------------------------------------------------------------------------------------------| | Registered Establishment Name: | COBE CARDIOVASCULAR (at time of 510(k) submission, now under<br>SORIN GROUP ITALIA S.R.L. responsibility) | | Regulation Number: | 21 CFR 870.4240 | | Regulation Name: | Cardiopulmonary bypass heat exchanger | | Regulatory Class: | Class II | | Product Code: | DTR | | 510(k) Number: | K012898 | {6}------------------------------------------------ Image /page/6/Picture/0 description: The image shows the logo for Qura advanced medical solutions. The logo features a stylized human figure with arms outstretched, enclosed within a curved line. To the right of the figure is the word "QURA" in bold, blue letters, with the words "advanced medical solutions" in smaller font underneath. #### DEVICE DESCRIPTION IV. The Qura S.r.l. Quantum PureFlow Heat Exchangers described in this 510(k) are classified in two different product families: - -Quantum PureFlow Standard Heat Exchanger (HX-S); - -Quantum PureFlow Cardioplegia Heat Exchanger (HX-C). The devices have been designed to manage the temperature of blood (HX-S) or cardioplegic solution and physiological fluids (HX-C) during surgical procedures requiring cardiopulmonary bypass (CPB) for periods lasting less than 6 hours. ### HX-S is designed to: - l keep circulating blood at a specific temperature, depending on the type of surgery being performed; - l maintain blood/patient thermoregulation during the CPB; - 트 rewarm blood at the conclusion of the CPB in order to restore normothermic patient condition. ### HX-C is designed to: - I ensure heating/cooling of cardioplegic solution; - 트 ensure the cardioplegic solution cooling in order to arrest myocardium activity during-CPB; - 트 remove air measure/monitor temperature in the circuit. - -Quantum PureFlow Heat Exchangers (both product families, HX-S and HX-C) described in this 510(k) have been designed to be powered by heater-cooler systems that use water as Heat Transfer Fluid (HTF). #### V. INTENDED USE / INDICATIONS FOR USE - -Quantum PureFlow Standard Heat Exchanger: The Quantum PureFlow Standard Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration. Devices are intended for adult patients. - Quantum PureFlow Cardioplegia Heat Exchanger: The Quantum PureFlow Cardioplegia Heat Exchanger is intended to be used with a compatible Heater/Cooler system to heat/cool cardioplegic solution, to remove air and to monitor the temperature during routine cardiopulmonary bypass (CPB) procedures up to 6 hours duration. Any blood to be treated must contain anticoagulant. Contact with cardioplegic solution for longer than this period is not permitted. Devices are intended for adult patients. {7}------------------------------------------------ Image /page/7/Picture/0 description: The image is a logo for Qura advanced medical solutions. The logo features a stylized human figure with arms outstretched, enclosed in a blue circle. The text "QURA" is written in large, bold, blue letters, with the words "advanced medical solutions" written in smaller letters underneath. #### COMPARISON OF TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE VI. Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger have the same intended use and operating principle as the predicate and reference devices (Apex Hp M Adult Hollow Fiber Membrane Oxygenator(for HX-S High Flow variant), D101 Kids Infant Hollow Fiber Membrane Oxygenator With Integrated Hardshell Cardiotomy/Venous Reservoir (reference for HX-S Medium Flow variant), D 100 Ph.I.S.I.O. (reference for HX-S Low Flow variants) and CSC14 Blood Cardioplegia System (for HX-C High and Medium Flow variants), cleared by K092895, K072091, K061031 and K012898, respectively). In-vitro performance tests have been performed to demonstrate that the proposed devices do not raise any new issues in terms of product's safety or effectiveness as compared to currently cleared products. Therefore, the Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger can be considered as substantially equivalent to predicate devices, according to FDA's Guidance "Evaluating Substantial Equivalence in Premarket Notifications [510(k)]," issued July 28, 2014. #### VII. PERFORMANCE DATA ### NON-CLINICAL TESTING The following non-clinical testing was performed to support the substantial equivalence of the Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger to the legally marketed predicate devices. This testing included biocompatibility evaluation, mechanical and performance verification, labeling and Instructions for Use (IFU), and verification and validation tests. All testing passed by meeting the established requirements set for the use of Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger devices. The following data were provided: - -Evaluation of devices' performances: - O Operating Parameters (priming volume, ease of prime, pressure drop); - O Air Entrapment (Air handling, Air Handling Through the Purging Port); - Mechanical Integrity; O - O Dynamic Blood Damage; - O Thermal Performance and Compliance; - -Performance evaluation according to ISO 7199:2016 [Recognition Nr. 3-150] (only for sections applicable to Heat Exchangers); - -Validation of the EtO Sterilization process, according to ISO 11135:2014 [Recognition Nr.: 14-529], - -Packaging Validation tests according to ISO 11607-1:2019 [Recognition Nr. 14-530]; - -Biocompatibility of the finished product (worst case conding to International Standard ISO 10993-1:2018 [Recognition Nr. 2-258] and FDA Guidance "Use of International Standard ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process". {8}------------------------------------------------ Image /page/8/Picture/0 description: The image shows the logo for Qura Advanced Medical Solutions. The logo features a stylized human figure with arms outstretched, enclosed within a curved shape. To the right of the figure is the word "QURA" in bold, blue letters, with the words "advanced medical solutions" in smaller font beneath it. ## Animal Study No animal studies have been performed except for mandatory biocompatibility tests according to International Standard ISO 10993-1:2018 [Recognition Nr. 2-258] and FDA Guidance "Use of International ISO 10993-1, "Biological evaluation of medical devices - Part 1: Evaluation and testing within a risk management process". ### CLINICAL TESTING No clinical data on Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger have been included in the current Traditional 510(k) submission. #### CONCLUSIONS VIII. Based on the indications for use, technological characteristics, results of non-clinical testing, and comparison to predicate devices, the Quantum PureFlow Standard Heat Exchanger and Quantum PureFlow Cardioplegia Heat Exchanger devices have been shown to be substantially equivalent to legally marketed predicate devices.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...