CHASE AORTIC ARCH CANNULA
Device Facts
| Record ID | K964193 |
|---|---|
| Device Name | CHASE AORTIC ARCH CANNULA |
| Applicant | Chase Medical, Inc. |
| Product Code | DWF · Cardiovascular |
| Decision Date | Apr 16, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.4210 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Aortic Arch Cannula is indicated for use for perfusion of the ascending aorta during surgical procedures requiring cardiopulmonary bypass in cases where aortic perfusion is deemed appropriate.
Device Story
Aortic arch cannula; used for perfusion of ascending aorta during cardiopulmonary bypass. Device features curved thin-wall beveled stainless steel tip; rigid plastic retention collar with indexing point for tip orientation; suture notches for securement; flexible plastic tubing; molded plastic connector for perfusion line attachment. Operated by surgeons in OR. Provides conduit for blood flow during bypass; facilitates surgical access to heart/aorta. Benefits patient by enabling extracorporeal circulation during cardiac surgery.
Clinical Evidence
Bench testing only. Leak testing (10 psi at 4°C and 40°C); tubing bond strength (>10 lb tensile at 4°C and 40°C); package integrity (ASTM F1140-88); shipping/distribution testing (NSTA vibration/drop); accelerated aging (2-year shelf life).
Technological Characteristics
Stainless steel tip; rigid plastic retention collar; flexible plastic tubing. Sterilization: Ethylene Oxide (Overkill Method, SAL 10⁻⁶). Packaging: Tyvek/Polymylar per ASTM F1140-88.
Indications for Use
Indicated for patients undergoing surgical procedures requiring cardiopulmonary bypass where ascending aortic perfusion is appropriate.
Regulatory Classification
Identification
A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to cannulate the vessels, perfuse the coronary arteries, and to interconnect the catheters and cannulas with an oxygenator. The device includes accessory bypass equipment.
Predicate Devices
- Sarns Aortic Arch Cannula (K770429)
Related Devices
- K123370 — EZ GLIDE AORTIC CANNULA, AORTIC PERFUSION CANNULA WITH DURAFLO COATING, DISPERSION AORTIC PERFUSION CANNULA · Edwards Lifesciences, LLC · Mar 13, 2013
- K964198 — CAHSE AORTIC ROOT CANNULA · Chase Medical, Inc. · Mar 19, 1997
- K974736 — HEARTPORT DIRECT AORTIC RETURN CANNULA WITH INTRODUCER · Heartport, Inc. · Jul 15, 1998
- K073559 — 18 FR. RMI ARTERIAL PERFUSION CANNULA II, 20 FR. RMI ARTERIAL PERFUSION CANNULA II · Edwards Lifesciences Research Medical · Jan 31, 2008
- K093730 — PORT ACCESS SYSTEMS ENDODIRECT ARTERIAL CANNULA MODEL ED24 (OLD CODE WAS-DFK24) · Edwards Lifesciences, LLC · Jan 14, 2010