DINAMAP PRO 1000 MONITOR WITH SUPERSTAT, MODEL 1000

K022834 · Ge Medical Systems Information Technologies · MHX · May 13, 2003 · Cardiovascular

Device Facts

Record IDK022834
Device NameDINAMAP PRO 1000 MONITOR WITH SUPERSTAT, MODEL 1000
ApplicantGe Medical Systems Information Technologies
Product CodeMHX · Cardiovascular
Decision DateMay 13, 2003
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1025
Device ClassClass 2
AttributesPediatric

Intended Use

The DINAMAP® Pro 1000 with SuperStat Monitor is intended to monitor the following adult, pediatric and neonate patient vital signs: Non-Invasive Blood Presure: · Able to measure oscillometric non-invasive blood pressure (systolic, diastolic and mean arterial pressure) · Will optimize performance in the presence of artifact due to vibration and patient motion. •Non-invasive blood pressure determinations acquired concurrently with the ECG parameter will report a determination in the presence of an irregular heart rhythm in the adult/pediatric mode. Heart/pulse rate, respiration rate, ECG Oxygen saturation (SpO2) by noninvasive pulse oximetry and Predictive temperature by resistive thermometry. The Pro 1000 with SuperStat Monitor also detects alarm limit conditions and is capable of recording up to two waveforms. Using the monitor a clinician can view, record and recall clinical data derived from each parameter.

Device Story

Monitor for adult, pediatric, and neonatal vital signs; inputs include oscillometric NIBP, ECG, SpO2, and resistive temperature sensors. Device processes signals to derive systolic, diastolic, and mean arterial pressure, heart/pulse rate, and respiration rate. Features SuperStat algorithm to optimize NIBP performance during motion/vibration and irregular heart rhythms. Used in hospitals and outpatient facilities by clinicians; portable via internal battery for intra-hospital transport. Outputs displayed on-screen; device records up to two waveforms and detects alarm limit conditions. Clinicians use data for patient assessment and clinical decision-making; networking capabilities allow central station monitoring.

Clinical Evidence

Clinical studies conducted to demonstrate performance of the SuperStat NIBP algorithm according to ANSI/AAMI SP10 standard (American National Standard for Electronic or Automated Sphygmomanometers).

Technological Characteristics

Software-driven electronic monitor; parameters include oscillometric NIBP (SuperStat algorithm), ECG, SpO2, and resistive thermometry. Connectivity via VHF, 900 MHz, or hardwire to central stations. Portable with internal battery. Compliant with ANSI/AAMI SP10 for NIBP.

Indications for Use

Indicated for monitoring vital signs (NIBP, heart/pulse rate, respiration, ECG, SpO2, temperature) in adult, pediatric, and neonatal patients in hospital, outpatient surgery, and healthcare facilities.

Regulatory Classification

Identification

The arrhythmia detector and alarm device monitors an electrocardiogram and is designed to produce a visible or audible signal or alarm when atrial or ventricular arrhythmia, such as premature contraction or ventricular fibrillation, occurs.

Special Controls

*Classification.* Class II (special controls). The guidance document entitled “Class II Special Controls Guidance Document: Arrhythmia Detector and Alarm” will serve as the special control. See § 870.1 for the availability of this guidance document.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image shows the General Electric (GE) logo. The logo consists of the letters 'G' and 'E' intertwined within a circular border. The letters and the border are in black, creating a strong contrast. The logo is simple, recognizable, and represents the General Electric brand. K022834 MAY 1 3 2003 General Electric Company 4502 Woodland Corporate Blvd., Tampa, FL 33614 813 887-2000 April 7, 2003 # SUMMARY OF SAFETY AND EFFECTIVENESS #### DINAMAP® Pro 1000 Monitor with SuperStat #### A. Submitter GE Medical Systems Information Technologies. 4502 Woodland Corporate Boulevard Tampa, FL 33614 #### B. Company Contact Primary: Melissa Robinson, Regulatory Affairs Specialist Secondary: Thomas English, Global QA/RA ### C. Device Name Pro 1000 Monitor with SuperStat Trade Name: Common Name: Physiological Monitor, Patient Monitor Classification/Device Product Code: System, Measurement, Blood Pressure, Noninvasive-870.1130-DXN Computer, Blood Pressure-870.1110-DSK Alarm, Blood Pressure-870.1100-DSJ Oximeter-870.2700-DQA Oximeter, Ear-870.2710-DPZ Thermometer, Clinical Electronic-880.2910-FLL Monitor, Cardiac (including cardiotachometer & rate alarm)-870.2300-DRT Electrocardiograph-870.2340-DPS Adapter, Lead Switching, Electrocardiograph-870.2350-DRW Arrhythmia Detection and Alarm-870.1025-DSI Monitor, Breathing Frequency-868.2375-BZO Recorder, Paper Chart-870.2810-DSF # D. Predicate/Legally Marketed Devices DINAMAP® Pro 1000 V2 Monitor, K012915 GE Medical Systems Information Technologies {1}------------------------------------------------ #### E. Device Description The DINAMAP® Pro 1000 Monitor w/ SuperStat is intended to monitor a single patient's vital signs in the hospital, outpatient surgery and healthcare practitioner facilities. The patient populations include adult, pediatric, and neonatal. The device's networking capabilities include connection to a central station via VHF, 900 MHz or hardwire communication: host communications for use with other devices. In addition, the DINAMAP Pro 1000 Monitor may be operated from internal batteries making the device portable and suitable for intra-hospital transport. #### F. Intended Use The DINAMAP® Pro 1000 with SuperStat Monitor is intended to monitor the following adult, pediatric and neonate patient vital signs: Non-Invasive Blood Pressure: · Able to measure oscillometric non-invasive blood pressure (systolic, diastolic and mean arterial pressure) · Will optimize performance in the presence of artifact due to vibration and patient motion. •Non-invasive blood pressure determinations acquired concurrently with the ECG parameter will report a determination in the presence of an irregular heart rhythm in the adult/pediatric mode. Heart/pulse rate, respiration rate, ECG Oxygen saturation (SpO2) by noninvasive pulse oximetry and Predictive temperature by resistive thermometry. The Pro 1000 with SuperStat Monitor also detects alarm limit conditions and is capable of recording up to two waveforms. Using the monitor a clinician can view, record and recall clinical data derived from each parameter. # G. Technological Characteristics The DINAMAP® Pro 1000 Monitor with SuperStat has the same technological characteristics as the predicate device, the DINAMAP® Pro 1000 V2 Monitor. There are no new technological characteristics. The Pro 1000 Monitor with SuperStat and the Pro 1000 V2 Monitor are both software-driven electronic devices that include the same monitoring parameters. # H. Parameter Technology The DINAMAP PRO 1000 Monitor with SuperStat has the following parameter technologies: ·SuperStat NIBP algorithm tested according to the ANSI/AAMI SP10 standard. - · Temperature-Same as the PRO 1000 V2 Monitor - ·SpO2-Same as the PRO 1000 V2 Monitor - •ECG-Same as the PRO 1000 V2 Monitor {2}------------------------------------------------ •Respiration-Same as the PRO 1000 V2 Monitor # I. Testing Clinical studies were conducted to demonstrate performance (safety and effectiveness) of the DINAMAP PRO 1000 with SuperStat Monitor to the ANSI/AAMI SP10 Standard: American National Standard for Electronic or Automated Sphygmomanometers. #### J. Conclusion The DINAMAP® Pro 1000 with SuperStat Monitor is substantially equivalent to the currently marketed DINAMAP® Pro 1000 V2 Monitor, K012915 cleared 3/21/02. {3}------------------------------------------------ Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 MAY 1 3 2003 GE Medical Systems Information Technologies c/o Ms. Melissa Robinson Regulatory Affairs Specialist 4502 Woodland Corporate Blvd. Tampa, FL 33614 Re: K022834 Trade Name: DINAMAP® Pro 1000 Monitor with SuperStat Regulation Number: 21 CFR 870.1025 Regulation Name: Arrhythmia Detector and Alarm Regulatory Class: Class III (three) Product Code: MHX Dated: March 17, 2003 Received: March 19, 2003 Dear Ms. Robinson: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA), You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act {4}------------------------------------------------ Page 2 – Ms. Melissa Robinson or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4646. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Delettu am D. Zucker rman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ April 7, 2003 # 510(K) Number (if known): Device Name: DINAMAP® Pro 1000 Monitor with SuperStat Indications for Use: The DINAMAP® Pro 1000 with SuperStat Monitor is intended to monitor the following adult, pediatric and neonate patient vital signs: Non-Invasive Blood Presure: - · Able to measure oscillometric non-invasive blood pressure (systolic, diastolic and mean arterial pressure) - · Will optimize performance in the presence of artifact due to vibration and patient motion. - •Non-invasive blood pressure determinations acquired concurrently with the ECG parameter will report a determination in the presence of an irregular heart rhythm in the adult/pediatric mode. Heart/pulse rate, respiration rate, ECG Oxygen saturation (SpO2) by noninvasive pulse oximetry and Predictive temperature by resistive thermometry. The Pro 1000 with SuperStat Monitor also detects alarm limit conditions and is capable of recording up to two waveforms. Using the monitor a clinician can view, record and recall clinical data derived from each parameter. (Please Do Not Write Below This Line-Continue On Another Page If Needed) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use (Per 21 CFR 801.109) Or Over-The Counter Use DeleTu **510(k) Number**
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...