K162228 · Aga Medical Corporation (Wholly Owned by St.Jude Medical Cor · DQY · Sep 9, 2016 · Cardiovascular
Device Facts
Record ID
K162228
Device Name
TorqVue Low Profile Delivery Catheter
Applicant
Aga Medical Corporation (Wholly Owned by St.Jude Medical Cor
Product Code
DQY · Cardiovascular
Decision Date
Sep 9, 2016
Decision
SESE
Submission Type
Special
Regulation
21 CFR 870.1250
Device Class
Class 2
Intended Use
The AMPLATZER™ TorqVue™ LP Catheter is intended to provide a pathway through which devices are introduced within the chambers and coronary vasculature of the heart or in the peripheral vasculature.
Device Story
The AMPLATZER TorqVue Low Profile Delivery Catheter (TVLPC) is a single-lumen, radiopaque catheter used to provide a pathway for introducing medical devices into the heart or peripheral vasculature. It is used by physicians under fluoroscopic guidance. The system includes a catheter, loader, Tuohy-Borst hemostasis valve, and a self-sealing hemostasis valve to control back-bleeding. The device is an extension of the predicate TorqVue Low Profile Delivery System (TVLP), modified by removing the delivery wire and offering only a 4 Fr size. It functions as a conduit for delivery of AMPLATZER occlusion devices. The device benefits patients by facilitating minimally invasive delivery of therapeutic implants.
Clinical Evidence
No clinical data. Substantial equivalence is based on bench testing, design verification, and design validation performed in previously cleared applications for the predicate TVLP (K131063) and AVP4 (K113658) devices, supplemented by packaging validation.
Technological Characteristics
Single-lumen, radiopaque catheter with a distal curve of approximately 90°. Includes loader, Tuohy-Borst hemostasis valve, and self-sealing hemostasis valve. 4 Fr size. Operates as a mechanical conduit for device delivery under fluoroscopy. No software or electronic components.
Indications for Use
Indicated for patients requiring a pathway for the introduction of devices into the heart chambers, coronary vasculature, or peripheral vasculature.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
Predicate Devices
AMPLATZER TorqVue Low Profile Delivery System (K131063)
K072313 — AMPLATZER TORQVUE DELIVERY SYSTEM · Aga Medical Corp. · Nov 2, 2007
K190581 — Amplatzer Trevisio Intravascular Delivery System · ABBOTT MEDICAL · Apr 5, 2019
K163000 — AMPLATZER TorqVue 45x45 Delivery Sheath · Aga Medical COrporation (Wholly Owned by St. Jude Medical CO · Dec 23, 2016
K121611 — AMPLATZER TORQVUE FX · Aga Medical Corporation · Aug 23, 2012
K080994 — AMPLATZER TORQVUE EXCHANGE SYSTEM · Aga Medical Corp. · May 16, 2008
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo is a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of three human profiles facing right, stacked on top of each other.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
September 9, 2016
AGA Medical Corporation (wholly owned by St. Jude Medical Corporation) Mary Johnson Specialist I, Regulatory Affairs 5050 Nathan Lane Plymouth. Minnesota 55442
Re: K16228
Trade/Device Name: AMPLATZER TorqVue Low Profile Delivery Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: DQY Dated: August 5, 2016 Received: August 8, 2016
Dear Mary Johnson:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical devicerelated adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in
{1}------------------------------------------------
the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely,
# Brian D. Pullin -S
for Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
### Indications for Use
510(k) Number (if known)
K162228
Device Name
AMPLATZER TorqVue Low Profile Delivery Catheter
Indications for Use (Describe)
The AMPLATZER™ TorqVue™ LP Catheter is intended to provide a pathway through which devices are introduced within the chambers and coronary vasculature of the heart or in the peripheral vasculature.
Type of Use (Select one or both, as applicable)
X Prescription Use (Part 21 CFR 801 Subpart D)
| Over-The-Counter Use (21 CFR 801 Subpart C)
#### CONTINUE ON A SEPARATE PAGE IF NEEDED.
This section applies only to requirements of the Paperwork Reduction Act of 1995.
#### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.*
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
{3}------------------------------------------------
## 510(K) SUMMARY
| Submitter: | AGA Medical Corporation<br>A wholly owned subsidiary of St. Jude Medical<br>5050 Nathan Lane<br>Plymouth, MN |
|----------------------|----------------------------------------------------------------------------------------------------------------------------|
| Contact Person: | Mary Johnson,<br>Regulatory Affairs Specialist I<br>Phone: 651-756-2213<br>Fax: 651-756-5744<br>E-mail: mjohnson16@sjm.com |
| Date Prepared: | August 5, 2016 |
| Trade Name: | AMPLATZER® TorqVue® Low Profile Delivery Catheter |
| Common Name: | Catheter Delivery System |
| Classification: | Class II, 21 CFR 870.1250<br>Catheter, Percutaneous |
| 510(k) Number: | K162228 |
| Product Code: | DQY |
| Predicate Device(s): | AMPLATZER TorqVue Low Profile Delivery System (K131063) |
{4}------------------------------------------------
AMPLATZER TorqVue Low Profile Delivery Catheter
The AMPLATZER TorqVue Low Profile Delivery Catheter (TVLPC) is an extension of Device Description: the AMPLATZER TorqVue Low Profile Delivery System (TVLP) product line. The TVLPC is identical to the TVLP with the exception of a delivery wire, which is omitted on the TVLPC catheter only product. The TorqVue LP Catheter includes a catheter, loader, Tuohy-Borst hemostasis valve, and a self-sealing hemostasis valve. The TorqVue LP Catheter is intended for use with AMPLATZER devices packaged with a delivery wire. Figure 1 illustrates the delivery system and identifies the following essential components: Catheter – Single-lumen catheter that is used to deliver the device after it has . been positioned by the physician. The body of the catheter is radiopaque to increase visibility when using fluoroscopy. The distal end of the catheter is curved approximately 90°. Tuohy-Borst hemostasis valve – An adapter designed to control back-bleeding ● from the Delivery Catheter. . Loader - catheter short tube with luer fittings that aids in placing the desired devices into the Delivery Catheter. ● Self-sealing hemostasis valve - An adapter designed to control back-bleeding from the Delivery Catheter. The self-sealing valve provides additional sealing capabilities for use with delivery wires of smaller diameters. Figure 1. TVLPC Components Self-Sealing Tuohy-Borst Hemostasis Valve Hemostasis Valve
Intended Use: The AMPLATZER TorqVue LP Catheter is intended to provide a pathway through
Catheter
which devices are introduced within the chambers and coronary vasculature of the heart or in the peripheral vasculature.
{5}------------------------------------------------
AMPLATZER TorqVue Low Profile Delivery Catheter
The AMPLATZER TorqVue LP Catheter is an extension of the AMPLATZER TorqVue Comparison to predicate: Low Profile Delivery System (K131063) product line. The predicate TorqVue LP Delivery System includes a catheter, loader, Tuohy-Borst hemostasis valve, delivery wire, and plastic vise for the delivery of AMPLATZER occlusion devices, while the Torq Vue LP Catheter includes a catheter, loader, Tuohy-Borst hemostasis valve, and a self-sealing hemostasis valve. The self-sealing hemostasis valve (referred to as hemostasis valve in AVP4 documentation) is identical to the one included with the currently marketed AMPLATZER Vascular Plug 4 (K113658).
The TVLPC differs from the TVLP in the following ways:
- . TVLPC Device only offered in 4 Fr size
- Removal of Delivery Wire ●
- Addition of Self-Sealing Hemostasis Valve
Table 1 summarizes the included components for each device.
| | TVLPC | TVLP | AVP4 |
|-------------------------------|-------|------|------|
| Catheter | ✓ | ✓ | |
| Loader | ✓ | ✓ | |
| Tuohy-Borst hemostasis valve | ✓ | ✓ | |
| Delivery Wire | | ✓ | |
| Vise | | ✓ | |
| Self-sealing hemostasis valve | ✓ | 4 Fr | ✓ |
| Sizes offered | 4Fr | 5 Fr | n/a |
#### Table 1. TVLPC vs. TVLP and AVP 4 Component Summarv
- Functional and The components of the TVLPC are identical to the 510(k) cleared predicate TVLP and Safety Testing: A VP4 devices. Design Verification and Design Validation testing has been performed and has been provided in cleared applications for the predicate TVLP (K131063) and A VP4 (K113658) devices. Separate packaging validation has been completed on the subject device.
- AGA Medical Corporation considers the 4 Fr AMPLATZER TorqVue Low Profile Conclusion: Delivery Catheter to be substantially equivalent to the TorqVue Low Profile Delivery System. This conclusion is based upon the devices' similarities in principles of operation, technology, materials and indications for use as identical components merely packaged differently from predicate devices.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.