AS/3 CARDIAC OUTPUT & SVO2 MODULE
Device Facts
| Record ID | K961063 |
|---|---|
| Device Name | AS/3 CARDIAC OUTPUT & SVO2 MODULE |
| Applicant | Datex Medical Instrumentation, Inc. |
| Product Code | DQK · Cardiovascular |
| Decision Date | May 31, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.1425 |
| Device Class | Class 2 |
Intended Use
The AS/3™ COPSv module is intended to be used in the Datex AS/3™ Anaesthesia Monitor or in the AS/3™ Compact Monitor in anesthesia department, in intensive care department etc.
Device Story
AS/3™ COPSv Module; modular component for Datex AS/3™ Anaesthesia/Compact Monitors. Inputs: thermodilution signals for C.O./REF; spectrophotometric data for SvO2; invasive pressure signals. Processing: licensed Baxter Edwards algorithms for C.O., REF, and SvO2 calculations. Output: real-time hemodynamic parameters displayed on monitor. Used in anesthesia/ICU by clinicians. Benefits: continuous hemodynamic monitoring to guide clinical decision-making.
Clinical Evidence
No clinical data provided; device relies on established thermodilution and spectrophotometric measurement techniques licensed from Baxter Edwards.
Technological Characteristics
Modular anesthesia monitoring component. Thermodilution technique for C.O./REF; spectrophotometric technique for SvO2. Hardware/software for C.O. and invasive pressure identical to K922876. Integrated measurement algorithms.
Indications for Use
Indicated for patients requiring cardiac output (C.O.), right ventricular ejection fraction (REF), mixed venous oxygen saturation (SvO2), and invasive pressure monitoring in anesthesia or intensive care settings.
Regulatory Classification
Identification
A programmable diagnostic computer is a device that can be programmed to compute various physiologic or blood flow parameters based on the output from one or more electrodes, transducers, or measuring devices; this device includes any associated commercially supplied programs.
Predicate Devices
- COP module (K922876)
Related Devices
- K052976 — DATEX-OHMEDA S/5 CARDIAC OUTPUT MODULE, E-COP AND ACCESSORIES · GE Healthcare · Jan 13, 2006
- K082308 — MODIFICATION TO VIGILEO ARTERIAL PRESSURE CARDIAC OUTPUT/OXIMETRY MONITOR · Edwards Lifesciences, LLC · Dec 9, 2008
- K103094 — VIGILEO ARTERIAL PRESSURE CARDIAC OUTPUT / OXIMETRY MONITOR; VIGILEO APCO / OXIMETRY MONITOR · Edwards Lifesciences, LLC · May 17, 2011
- K163381 — HemoSphere Advanced Monitor, HemoSphere Swan-Ganz Module, HemoSphere Oximetry Cable · Edwards Lifesciences, LLC · Apr 14, 2017
- K122121 — PULSIOFLEX MONITORING SYSTEM WITH PICCO MODULE · Pulsion Medical Systems SE · Aug 2, 2012