INDEFLATOR PLUS 30/PLUS 30 PRIORITY PACK9WITH THE.096 OR.115 ROTATING HEMOSTATIC VALVE)
Device Facts
| Record ID | K962495 |
|---|---|
| Device Name | INDEFLATOR PLUS 30/PLUS 30 PRIORITY PACK9WITH THE.096 OR.115 ROTATING HEMOSTATIC VALVE) |
| Applicant | Advanced Cardiovascular Systems, Inc. |
| Product Code | MAV · Cardiovascular |
| Decision Date | Sep 12, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.1650 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The INDEFLATOR PLUS 30™ Inflation Device is recommended for use during vascular procedures in conjunction with interventional devices such as balloon catheters to create and monitor pressure in the balloon catheter. The PLUS 30 PRIORITY PACK™: INDEFLATOR PLUS 30™ Inflation Device- See description above. PLUS 30 PRIORITY PACK™ Accessory Kit- The Accessory Kit is recommended for use during vascular procedures in conjunction with interventional and/or diagnostic devices (e.g., balloon dilatation catheters, arthrectomy devices, stent delivery systems, intravascular ultrasound devices.)
Device Story
Manually operated inflation device; pressurizes/depressurizes balloon catheters; monitors pressure via integrated gauge. PLUS 30 PRIORITY PACK includes inflation device plus accessories: torque device, guide wire introducer, rotating hemostatic valve. Used in vascular procedures by clinicians (physicians/technicians) to facilitate balloon dilatation, stent delivery, or diagnostic imaging. Output is controlled pressure applied to interventional devices; enables precise balloon inflation for vessel treatment. Benefits include controlled, monitored pressure delivery during interventional procedures.
Clinical Evidence
Bench testing only; no clinical data provided. Substantial equivalence based on design and functional similarity to predicate devices.
Technological Characteristics
Mechanical inflation device; manual operation; integrated pressure gauge. Includes accessory kit (torque device, guide wire introducer, rotating hemostatic valve). No software or electronic components.
Indications for Use
Indicated for patients undergoing vascular procedures requiring inflation/deflation of interventional or diagnostic devices (e.g., balloon catheters, atherectomy devices, stent delivery systems, IVUS). No specific age or gender contraindications stated.
Regulatory Classification
Special Controls
*Classification.* Class II (special controls). The device, when it is a non-patient contacting balloon inflation syringe intended only to inflate/deflate balloon catheters and monitor pressure within the balloon, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.
Predicate Devices
Related Devices
- K961471 — INDEFLATOR 20/30 INFLATION DEVICE AND 20/30 PRIORITY PACK (WITH THE .096 OR .115 ROTATING HEMOSTATIC VALVE) · Advanced Cardiovascular Systems, Inc. · May 8, 1996
- K102648 — ANT INFLATION DEVICE/ANT INFLATION DEVICE COMPACT PACK · Shenzhen Ant Hi-Tech Industrial Co., Ltd. · Jul 1, 2011
- K955869 — SCIMED ENCORE 26 INFLATION DEVICE/ENCORE 30 INFLATION DEVICE · Scimed Life Systems, Inc. · Mar 22, 1996
- K140943 — MASTRO PLUS BALLOON IN-DEFLATION DEVICE · Beijing Demax Medical Technology Co.,Ltd · Mar 5, 2015
- K122321 — BASIXCONPAK ANALOG INFLATION SYRINGE · Merit Medical Ireland, Ltd. · Dec 19, 2012