ULTRA-THIN DIAMOND BALLOON DILATATION CATHETER

K960501 · Boston Scientific Corp · LIT · Apr 9, 1996 · Cardiovascular

Device Facts

Record IDK960501
Device NameULTRA-THIN DIAMOND BALLOON DILATATION CATHETER
ApplicantBoston Scientific Corp
Product CodeLIT · Cardiovascular
Decision DateApr 9, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1250
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The Diamond™ Vessel Balloon Dilatation Catheter is indicated for PTA of the iliac, femoral and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.

Device Story

Over-the-wire balloon dilatation catheter; designed for use with guidewires ≤.035" diameter. Used by clinicians for percutaneous transluminal angioplasty (PTA) of iliac, femoral, and renal arteries; treatment of obstructive lesions in arteriovenous dialysis fistulae. Available with or without Glidex™ and Medi-Glide™ coatings. Device facilitates vessel dilation via balloon inflation; provides mechanical intervention to restore patency in stenotic vessels/fistulae.

Clinical Evidence

Bench testing only. In vitro functional tests: balloon burst, multiple inflation, inflation/deflation time, compliance, proximal bond, sheath withdrawal, wingfolded profile, coating slip/adhesion, coefficient of friction, particulate analysis, solvent residual. Biocompatibility: cytotoxicity, hemolysis, USP Class IV, mutagenicity, sensitization, thrombogenicity, pyrogenicity, 90-day muscle implantation.

Technological Characteristics

Over-the-wire balloon dilatation catheter; compatible with guidewires ≤.035". Features optional Glidex™ and Medi-Glide™ coatings. Biocompatible materials tested per USP Class IV and 90-day muscle implantation standards. Mechanical design includes balloon inflation/deflation mechanism for vessel dilation.

Indications for Use

Indicated for percutaneous transluminal angioplasty (PTA) of iliac, femoral, and renal arteries; treatment of obstructive lesions in native or synthetic arteriovenous dialysis fistulae.

Regulatory Classification

Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} 03/20/96 10.00 0000 BSC/CLINICAL RSH →→ CDRH ODE 003 Medi-tech Ultra-thin™ Diamond™ Balloon Dilatation Catheter K. 966501 February 1, 1996 # ATTACHMENT H ## SUMMARY OF SAFETY AND EFFECTIVENESS Pursuant to §513(i)(3)(A) of the Food, Drug, and Cosmetic Act, Boston Scientific Corporation is required to submit with this Premarket Notification either an "... adequate summary of any information respecting safety and effectiveness or state that such information will be made available upon request of any person." Boston Scientific Corporation choose to submit a summary of information respecting safety and effectiveness. According to §513(i)(3)(B), "Any summary under subparagraph (A) respecting a device shall contain detailed information regarding data concerning adverse health effects..." The summary regarding the adverse health effects of the proposed Diamond™ Balloon Dilatation Catheter is as follows: **Trade Name:** Diamond™ Balloon Dilatation Catheter **Manufacturer:** Boston Scientific Corporation One Boston Scientific Place Natick, MA 01760 **Device Generic Name:** Balloon Dilatation Catheter **Classification:** According to Section 13 of the Federal Food, Drug and Cosmetic Act, the device classification is Class II, Performance Standards. **Predicate Devices:** The following devices are referenced in this premarket notification as predicate devices for the Diamond™ Balloon Dilatation Catheter: - BSC -- Blue Max Balloon Dilatation Catheter - BSC -- Ultra-thin™ Balloon Catheter - BSC -- Symmetry™ Small Vessel Balloon Dilatation Catheter - BSC -- Courier™ Balloon Dilatation Catheter All of the devices mentioned above have been determined substantially equivalent by FDA. **Device Description:** The proposed Diamond™ Balloon Dilatation catheter is an over-the-wire catheter indicated for percutaneous transluminal angioplasty of the iliac, femoral and renal arteries and for treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. The proposed device is designed to be placed over guidewires which have outer diameters of .035" or smaller. The device is offered with and without Glidex™ and Medi-Glide™ coatings. {1} 03/20/96 12:05 8SC, CLINICAL FSH ---> CDRH ODE 004 Medi-tech Ultra-thin™ Diamond™ Balloon Dilatation Catheter February 1, 1996 ## Indications for Use: The Diamond™ Vessel Balloon Dilatation Catheter is indicated for PTA of the iliac, femoral and renal arteries and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae. ## Safety and Performance: The following in vitro frunctional tests were performed on the Diamond™ Balloon Dilatation Catheter: - Balloon Burst Testing - Multiple Inflation Testing - Inflation/Deflation Time Testing - Balloon Compliance Testing - Balloon Proximal Bond Testing - Sheath Withdrawal Testing - Wingfolded Balloon Profile Testing - Coating Slip/Adhesion Testing - Coating Coefficient of Friction Testing - Particulate Analysis Testing - Solvent Residual Testing The following biocompatibility tests were performed: - Cytotoxicity - Hemolysis - U.S.P. Class IV - Mutagenicity - Sensitization - Thrombogenicity - Pyrogenicity - 90-Day Muscle Implantation ## Conclusion: Based on the Indication for Use, technological characteristics and safety and performance testing, the Diamond™ Balloon Dilatation Catheter has been shown to be safe and effective for its intended use.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...