← Product Code [DYB](/submissions/CV/subpart-b%E2%80%94cardiovascular-diagnostic-devices/DYB) · K060190

# SUPER SHEATH XL INTRODUCER SHEATH (K060190)

_Togo Medikit Co., Ltd. · DYB · Apr 4, 2006 · Cardiovascular · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/CV/subpart-b%E2%80%94cardiovascular-diagnostic-devices/DYB/K060190

## Device Facts

- **Applicant:** Togo Medikit Co., Ltd.
- **Product Code:** [DYB](/submissions/CV/subpart-b%E2%80%94cardiovascular-diagnostic-devices/DYB.md)
- **Decision Date:** Apr 4, 2006
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 870.1340
- **Device Class:** Class 2
- **Review Panel:** Cardiovascular

## Indications for Use

The Medikit Super Sheath Introducer Sheaths and Super Sheath Introducer Sheath Sets are indicated for use in the introduction of diagnostic and interventional devices inserted into the human vasculature.

## Device Story

Super Sheath XL Introducer Sheath facilitates entry of diagnostic/interventional devices into human vasculature; consists of sheath, dilator, and optional mini guidewire. Sheath shaft/hub constructed of polyamide and FEP; includes hemostatic valve to prevent blood leakage and side tube with three-way stopcock for fluid/medication administration or blood sampling. Dilator features tapered distal tip and luer hub for guidewire insertion. Operated manually by clinicians in clinical settings. Sheath provides smooth passage for medical devices; dilator supports sheath entry into vasculature. Once sheath is positioned, dilator is removed. Benefits include controlled vascular access for interventional procedures.

## Clinical Evidence

Bench testing only. Performed sheath shaft/hub tensile tests, kink tests, hemostatic valve integrity/pressure tests, and dilator tensile tests. Biocompatibility, lubricity, radiopacity, and corrosion resistance data were leveraged from predicate K052557.

## Technological Characteristics

Materials: Polyamide and fluorinated ethylene propylene (FEP). Design: Introducer sheath with hemostatic valve, side tube with three-way stopcock, and tapered dilator. Sizes: 10F, 11F, 12F, 14F. Lengths: 11-25 cm. Operation: Manual. Sterilization: Sterile, single-use.

## Regulatory Identification

A catheter introducer is a sheath used to facilitate placing a catheter through the skin into a vein or artery.

## Predicate Devices

- Medikit Super Sheath Introducer Sheaths and Super Sheath Introducer Sheath Sets ([K052557](/device/K052557.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

APR 4 ZUDE

Special 510(k) Notification Togo Medikit Co. LTD Introducer Sheaths and Introducer Sheath Sets

General Provisions

K 060190

. J

## Section 7

7.1

Summary of Safety and Effectiveness

### (Pursuant To Section 12 of the SAFE MEDICAL DEVICES ACT of 1990)

| Submitter's Name and Address | Togo Medikit Co. Ltd.<br>17148-6, Aza Kamekawa, Oaza Hichiya, Hyuga City<br>Miyazaki Prefecture 883-0062<br>Japan                               |
|------------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------|
| Contact Name and Information | Toshimitsu Hayashi<br>Quality Assurance Manager<br>Phone: 81-982-53-8027<br>Fax: 81-982-53-8008<br>e-mail: toshimitsu.hayashi@togomedikit.co.jp |
| Applicant                    | Heidi M. Erickson<br>Specialist, Regulatory Affairs<br>Phone: 763-694-3028<br>Fax: 763-694-6966<br>e-mail: ericksoh@bsci.com                    |
| Proprietary Name(s)          | Super Sheath XL Introducer Sheath                                                                                                               |
| Common Name                  | Catheter Introducer                                                                                                                             |
| Product Code                 | DYB                                                                                                                                             |
| Classification of Device     | Class II, 21 CFR Part 870.1340                                                                                                                  |

#### 7.2 Name of Predicate Device

Medikit Super Sheath Introducer Sheaths and Super Sheath Introducer Sheath Sets

{1}------------------------------------------------

#### 7.3 Device Description

The Medikit Super Sheath Introducer XL Sheaths and Super Sheath XL Introducer Sheath Sets are similar to the 4-9F sheaths with the addition of four French sizes to the sheath line.

The Super Sheath XL Introducer Sheaths are available in 10F, 11F, 12F and 14F sizes and available in lengths ranging from 11 to 25 cm. The devices are provided sterile and are intended for one procedure use only.

The Medikit Super Sheath XL Introducer Sheath is packaged with a dilator. The Super Sheath Introducer XL Sheath Set consists of a sheath, a dilator and a mini guidewire, with inserter. The mini guidewires with inserter were cleared to market in K052557 (January 17, 2006). The construction of the sheath shaft and hub allows smooth passage of medical devices. The sheath shaft and hub are made of polyamide and fluorinated ethylene propylene FEP (Teflon). The hubs, color-coded by French size, contain a hemostatic valve to prevent blood leakage during a procedure. A side tube equipped with a three-way stopcock is attached to the sheath hub. The side tube extension may be used for fluid and medication administration as well as blood sampling.

The dilator is an open tapered plastic tube with an integral luer hub for guidewire insertion. The guidewire is inserted into the introducer sheath and facilitates and supports the entry of the sheath into the patient's vasculature. The dilator is longer than the sheath with a rounded tapered distal tip. Once the sheath is in place the dilator is removed. The dilators are 0.038" and a 0.035" guidewire compatible. The dilator tubes are made of fluorinated ethylene propylene (FEP). The dilator tubes are attached to the dilator hub using an epoxy resin. The sheath hub and the dilator hub lock using a rotating motion.

#### 7.4 Intended Use

The Medikit Super Sheath Introducer Sheaths and Super Sheath Introducer Sheath Sets are indicated for use in the introduction of diagnostic and interventional devices inserted into the human vasculature.

#### 7.5 Summary of Technological Characteristics

The Medikit Super Sheath XL Introducer Sheaths and Super Sheath XL Introducer Sheath Sets are operated manually or by a manual process. The Medikit Super Sheath XL Introducer Sheaths and Super Sheath XL Introducer Sheath Sets use similar product design, packaging, sterilization methods and labeling when compared to the 4-9F sheaths (K052557). The similar indications for use and technological characteristics support a determination of substantial equivalence. Differences in materials do not raise any new issues of safety and effectivencss.

{2}------------------------------------------------

#### 7.6 Non-clinical Test Summary

Testing was conducted to verify that the Super Sheath XL Introducer Sheaths met product specification. The following testing was performed:

- Sheath Shaft Tensile test
- Sheath Kink Test ●
- Sheath Hub to Shaft Tensile Test .
- Hemostatic Valve Integrity/Sheath Pressure Test ●
- Sheath Valve Integrity/Sheath Pressure Test
- . Dilator Shaft Tensile Test
- Dilator Hub to Shaft Tensile Test
- . Real Time Product Shelf Lift Testing

Lubricity, radiopacity, sheath/dilator corrosion resistance testing, biocompatibility and package test reports were provided in K052557. The devices tested included the materials and packaging used in the devices included in this Special 510(k) notification. No new testing was conducted.

Test results verified that the Super Sheath XL Introducer Sheaths and Super Sheath XL Introducer Sheath Sets are adequate for their intended use. Based on a comparison of intended use, design and the results of bench testing, Medikit 10F, 11F, 12F, and 14F Super Sheath XL Introducer Sheaths and Super Sheath XL Introducer Sheath Sets have been shown to be substantially equivalent to the predicate (K052557) device.

{3}------------------------------------------------

Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized depiction of an eagle or bird-like figure with three curved lines representing its body and wings. The logo is encircled by the text "DEPARTMENT OF HEALTH AND HUMAN SERVICES USA" in a circular arrangement.

Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850

APR 4 2006

TOGO Medikit Co., Ltd. c/o Boston Scientific 5905 Nathan Lane Mail Stop P-25 Plymouth, MN 55442 Attn: Ms. Heidi M. Erickson

Re: K060190 Super Sheath XL Introducer Sheath Regulation Number: 21 CFR 870.1340 Regulation Name: Catheter introducer Regulatory Class: II Product Code: DYB Dated: March 15, 2006 Received: March 16, 2006

Dear Ms. Erickson:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, EDA over publish further announcements concerning your device in the Federal Register.

{4}------------------------------------------------

Page 2 - Ms. Heidi M. Erickson

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.

Sincerely yours.

vvie R. Viclner

\ Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health

Enclosure

{5}------------------------------------------------

Special 510(k) Notification Togo Medikit Co. LTD Introducer Sheaths and Introducer Sheath Sets

### Section 5

### Indications for Use

# Indications for Use

Kobo ic

510(k) Number (if known): Kobol 90

Device Name: Guide Sheaths and Guide Sheath Sets

Indications for Use: The Medikit Super Sheath Introducer Sheaths and Super Sheath Introducer Sheath Sets are indicated for use in the introduction of diagnostic and interventional devices inserted into the human vasculature.

Prescription Use X _ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (Part 21 CFR 801 Subpart D)

AND/OR

Over-The-Counter Use (21 CFR 801 Subpart C)

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

Duna R. de Line
(Division Sign-Off)

、 ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・

Division of Cardiovascular Devices

510(k) Number ن ( ( ( 1 ) 0 ( 1 ) 0

Confidential

---

**Source:** [https://fda.innolitics.com/submissions/CV/subpart-b%E2%80%94cardiovascular-diagnostic-devices/DYB/K060190](https://fda.innolitics.com/submissions/CV/subpart-b%E2%80%94cardiovascular-diagnostic-devices/DYB/K060190)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
