K020766 · Health & Life Co., Ltd. · DXN · Apr 5, 2002 · Cardiovascular
Device Facts
Record ID
K020766
Device Name
HL168F
Applicant
Health & Life Co., Ltd.
Product Code
DXN · Cardiovascular
Decision Date
Apr 5, 2002
Decision
SESE
Submission Type
Special
Regulation
21 CFR 870.1130
Device Class
Class 2
Indications for Use
Measures automatically human's Systolic, Diastolic blood pressure and heart rate using the oscillometric method. All values can be read out in one LCD Panel . The intended for use of this over-the-counter device is for age 16 and above.
Device Story
HL168F is an automatic non-invasive blood pressure (NIBP) monitor; utilizes oscillometric method to measure systolic/diastolic blood pressure and heart rate; intended for over-the-counter use by individuals aged 16 and above; device displays results on an integrated LCD panel; provides automated physiological monitoring for home or clinical settings.
Clinical Evidence
No clinical data provided; substantial equivalence determination based on regulatory review of device specifications and intended use.
Technological Characteristics
Non-invasive blood pressure measurement system; oscillometric sensing principle; LCD display; intended for over-the-counter use; Class II device (Product Code DXN).
Indications for Use
Indicated for individuals aged 16 and older for the automatic measurement of systolic and diastolic blood pressure and heart rate using the oscillometric method.
Regulatory Classification
Identification
A noninvasive blood pressure measurement system is a device that provides a signal from which systolic, diastolic, mean, or any combination of the three pressures can be derived through the use of tranducers placed on the surface of the body.
Related Devices
K033043 — MODIFICATION TO HL168 · Health & Life Co., Ltd. · Oct 10, 2003
K031695 — HL168R · Health & Life Co., Ltd. · Jul 1, 2003
K014122 — HL168E · Health & Life Co., Ltd. · Jan 16, 2002
K013033 — MODIFICATION TO: HL168W TOUCH SCREEN · Health & Life Co., Ltd. · Oct 23, 2001
K012310 — MODIFICATION TO:HL168D BLOOD PRESSURE MONITOR · Health & Life Co., Ltd. · Aug 22, 2001
Submission Summary (Full Text)
{0}------------------------------------------------
#### DEPARTMENT OF HEALTH & HUMAN SERVICES
Image /page/0/Picture/1 description: The image shows the words "HUMAN SERV" in bold, black font. The letters are closely spaced and appear to be part of a larger phrase or title. The text is clear and legible against a white background.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
APR - 5 2002
Ms. Susan Chen Health & Life Co., Ltd. 6F, No. 407, Chung Shan Road, Sec. 2 Chung Ho City, Taipei Hsien TAIWAN R.O.C.
Re: K020766
Trade Name: HL168F Regulation Number: 21 CFR 870.1130 Regulation Name: Non-invasive Blood Pressure Measurement System Regulatory Class: Class II (two) Product Code: DXN Dated: March 7, 2002 Received: March 8, 2002
Dear Ms. Chen:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
### Page 2 - Ms. Susan Chen
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing. (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 21 CFR Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4646. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
\$\mathcal{f}\$
Bram D. Zuckerman, M.D. Acting Director Division of Cardiovascular and Respiratory Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
# 510(k) Number (if known) :
Device Name : Full Automatic (NIBP) Blood Pressure Monitor
Trade Name : HL168F
## Indications For Use
Measures automatically human's Systolic, Diastolic blood pressure and heart rate using the oscillometric method. All values can be read out in one LCD Panel .
The intended for use of this over-the-counter device is for age 16 and above.
Concurrence of CDRH, Office of Device Evaluation (ODE)
Prescription USE ( ) (Per 21 CFR 801.109) OR
Over-The-Counter Use( V ) ( Optional Format 1-2)
f Cardiovascular & respiratory Devices
mber 12020 1706
4 ਦ
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.