K965051 · Heartport, Inc. · DRC · Mar 12, 1997 · Cardiovascular
Device Facts
Record ID
K965051
Device Name
HEARTPORT NEEDLE TROCAR
Applicant
Heartport, Inc.
Product Code
DRC · Cardiovascular
Decision Date
Mar 12, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 870.1390
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
The Heartport Needle Trocars are intended to provide access to the thoracic cavity. The Heartport Needle Trocar allows suture snares and similar small devices to be inserted and used during minimally invasive cardiothoracic surgery procedures.
Device Story
Needle trocar; provides thoracic cavity access; facilitates insertion of suture snares/small instruments during minimally invasive cardiothoracic surgery. Used by surgeons in clinical/OR settings. Device design/performance equivalent to biopsy needles; enables instrument passage through thoracic wall.
Clinical Evidence
Bench testing only; no clinical data provided. Equivalence established via design and performance comparison to predicate devices.
Technological Characteristics
Needle-based trocar design; biocompatible materials. Mechanical device for thoracic access. No software or electronic components.
Indications for Use
Indicated for patients undergoing minimally invasive cardiothoracic surgery requiring thoracic cavity access for insertion of suture snares or similar small devices.
Regulatory Classification
Identification
A trocar is a sharp-pointed instrument used with a cannula for piercing a vessel or chamber to facilitate insertion of the cannula.
Special Controls
*Classification.* Class II (special controls). Except for trocars that are reprocessed for multiple use, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 870.9.
Predicate Devices
Heartport Surgical Thoracic Trocar
Popper & Sons Biopsy Needle
Related Devices
K964302 — HEARTPORT THORACIC TROCAR · Heartport, Inc. · May 9, 1997
K961463 — HEARTPORT THORACIC SURGICAL TROCARS: (TOST-4-3, TOSTL-6-3, TON-4-2 AND TONL-6-2 · Heartport, Inc. · Oct 8, 1996
K091350 — ESTECH HAWKEYE INTRODUCER SYSTEMS · Endoscopic Technologies, Inc. D/B/A Estech · Sep 15, 2009
K150549 — Reactor(TM) Trocar and Sleeve · Sharp Medical Prducts, LLC · Jun 1, 2015
K063859 — SURGIQUEST ELASTOMERIC OPTICAL TROCAR & CANNULA · Surgiquest, Inc. · Mar 14, 2007
Submission Summary (Full Text)
{0}
Heartport™ Needle Trocars
Appendices
# APPENDIX B. 510(K) SUMMARY OF SAFETY AND EFFECTIVENESS
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of SMDA 1990 and 21 CFR 807.92.
The assigned 510(k) number is: **K965051**
MAR 12 1997
## Applicant Information:
Date Prepared: December 17, 1996
Name: Heartport, Inc.
Address: 200 Chesapeake Drive
Redwood City, CA 94063
Contact Person: Marianne C. Drennan
Phone Number: (415) 482-4405
Fax Number: (415) 482-4346
## Device Information:
Classification: Class II
Trade Name: Heartport™ Needle Trocar
Classification Name: Cardiovascular Devices - Trocar
21 CFR 870.1390
## Equivalent Devices:
The Heartport Needle Trocar is substantially equivalent in intended use and/or method of operation to the Heartport Surgical Thoracic Trocar and the Popper & Sons Biopsy Needle.
## Intended Use:
The Heartport Needle Trocars are intended to provide access to the thoracic cavity. The Heartport Needle Trocar allows suture snares and similar small devices to be inserted and used during minimally invasive cardiothoracic surgery procedures.
## Comparison To Predicate Devices:
The Heartport Needle Trocars are equivalent in intended use to the Heartport Surgical Thoracic Trocars. They are equivalent in operational characteristics to the Popper & Sons Biopsy Needles.
Heartport, Inc.
CONFIDENTIAL
Page 18
{1}
Heartport™ Needle Trocars
Appendices
## 510(k) Summary of Safety and Effectiveness, continued
### Non-Clinical Test Results:
#### Performance
The Heartport Needle Trocar is identical to the Popper & Sons Biopsy Needle in design and performance characteristics. As this predicate device has been successfully marketed for many years with well established performance, no further testing is warranted.
#### Biocompatibility
The materials used in the Heartport Needle Trocar have proven biocompatibility.
### Summary:
Based on the intended use, product, performance and biocompatibility information provided in this Notification, Heartport Needle Trocars have been shown to be substantially equivalent to a combination of currently marketed predicate devices.
Heartport, Inc.
CONFIDENTIAL
Page 19
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.