7F ACUMEN CORONARY SINUS VISUALIZATION SYSTEM, MODEL CSVS-7-67
K062084 · Acumen Medical, Inc. · DQY · Aug 18, 2006 · Cardiovascular
Device Facts
Record ID
K062084
Device Name
7F ACUMEN CORONARY SINUS VISUALIZATION SYSTEM, MODEL CSVS-7-67
Applicant
Acumen Medical, Inc.
Product Code
DQY · Cardiovascular
Decision Date
Aug 18, 2006
Decision
SESE
Submission Type
Special
Regulation
21 CFR 870.1250
Device Class
Class 2
Indications for Use
The 7F Acumen Coronary Sinus Visualization System is intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.
Device Story
7F Acumen Coronary Sinus Visualization System (CSVS) is a single-use percutaneous catheter; used to visualize coronary sinus, provide temporary occlusion during venogram, and serve as delivery pathway for transvenous devices to coronary sinus and coronary vasculature. Operated by clinicians in clinical settings. Device facilitates diagnostic and interventional procedures by providing access and visualization support.
Clinical Evidence
Bench testing only; all components and subassemblies met required specifications.
Technological Characteristics
Single-use percutaneous catheter; 7F size. Materials are identical to those used in the predicate device and previously cleared products.
Indications for Use
Indicated for patients requiring coronary sinus visualization, temporary occlusion during venography, and delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.
Regulatory Classification
Identification
A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.
Predicate Devices
Acumen Coronary Sinus Visualization System (K042381)
K070051 — ACUMEN INSIGHT ENDOCARDIAL VISUALIZATION SYSTEM · Acumen Medical, Inc. · Apr 6, 2007
K033989 — MEDTRONIC SELECTSITE DEFLECTABLE CATHETER SYSTEM, MODELS C304-S59 AND C304-L69 · Medtronic Inc. Cardiac Rhythm Management · Jan 22, 2004
K973298 — CARDIMA VUEPORT CORONARY SINUS BALLOON OCCLUSION GUIDING CATHETER · Cardima, Inc. · Jun 26, 1998
K243757 — Shockwave CS Guide Catheter · Shockwave Medical, Inc. · May 2, 2025
Submission Summary (Full Text)
{0}------------------------------------------------
K062084
p. 1 of 2
Acumen Medical, Inc.
# AUG 1 8 2006
#### 510(k) Summary 5.
General Information
Date Compiled Classification Trade Name
Submitter
July 18, 2006
Class II
7F Acumen Coronary Sinus Visualization System
Acumen Medical, Inc. 275 Santa Ana Court Sunnyvale, CA 94085
Tel: 408-530-1810 Fax: 408-530-1811
Contact
Marybeth Gamber Director, Regulatory Affairs
## Intended Use
The 7F Acumen Coronary Sinus Visualization System is intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.
Predicate Devices
Acumen Coronary Sinus Visualization System K042381 Manufactured by Acumen Medical, Inc.
#### Device Description
The 7F Acumen Coronary Sinus Visualization System (CSVS) is a single-use percutaneous catheter intended to aid in the visualization of the coronary sinus, provide temporary occlusion during a venogram, and to provide a pathway for delivery of transvenous devices to the coronary sinus and coronary vasculature of the heart.
#### Materials
All materials used in the manufacture of the 7F Acumen Coronary Sinus Visualization System are suitable for this use, are identical to the those used in the predicate device, and have been used in numerous previously cleared products
#### Testing
Appropriate testing has been performed and all components, subassemblies, and/or full devices met the required specifications for the completed tests.
#### Summary of Substantial Equivalence
Acumen Medical, Inc. believes the 7F Acumen Coronary Sinus Visualization System is substantially equivalem to the predicate product. The imended use, method of operation,
{1}------------------------------------------------
:
1
.
### Acumen Medical, Inc.
:
.
:
:
and the same of the same of the states of the states of the states
methods of construction and materials used, are either identical or substantially equivalent to existing legally marketed predicate product.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
:
Confidential
·
:
{2}------------------------------------------------
Image /page/2/Picture/2 description: The image shows the logo for the U.S. Department of Health and Human Services. The logo features a stylized caduceus, which is a symbol often associated with medicine and healthcare. The caduceus is positioned to the right of the circular text that reads "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA". The logo is simple and monochromatic.
#### Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
## AUG 1 8 2006
Acumen Medical, Inc. c/o Marybeth Gamber Director, Regulatory Affairs 275 Santa Ana Court Sunnyvale, CA 94085
Re: K062084
Trade Name: 7F Acumen Coronary Sinus Visualization System, Model (CSVS) Regulation Number: 21 CFR §870.1250 Regulation Name: Percutaneous Catheter Regulatory Class: Class II Product Code: DQY Dated: August 9, 2006 Received: July 21, 2006
Dear Ms. Gamber:
We have reviewed your Section 510(k) premarket notification of intent to market the device we nave reviewed four becamed the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for use surver to May 28, 1976, the enactment date of the Medical Device Amendments, or to conimer to province of the ) 2011-07-12 in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The I va may, atteres, and include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{3}------------------------------------------------
Page 2 – Ms. Marybeth Gamber
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html.
Sincerely yours.
Q.B.M.
FOR Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{4}------------------------------------------------
Acumen Medical, Inc.
#### Indications for Use Statement 4. ﭗ ﮨﺎ
:
| 510(k) Number (if known): | This application |
|---------------------------|-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Device Name: | 7F Acumen Coronary Sinus Visualization System |
| Indications for Use: | The 7F Acumen Coronary Sinus Visualization System is<br>intended to aid in the visualization of the coronary sinus,<br>provide temporary occlusion during a venogram, and to<br>provide a pathway for delivery of transvenous devices to the<br>coronary sinus and coronary vasculature of the heart. |
Prescription Use __X (Per 21 CFR 801 Subpari D) AND/OR
Over-The-Counter Use (Per 21 CFR 801 Subpari C)
# PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Q.S.M.
(Division Sign-Off) Division of Cardiovascular Devices 510(k) Number -Ko 62084
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.