MINI GHOST PTA CATHETER, MODEL 507

K051343 · NuMED, Inc. · DQY · Jul 28, 2005 · Cardiovascular

Device Facts

Record IDK051343
Device NameMINI GHOST PTA CATHETER, MODEL 507
ApplicantNuMED, Inc.
Product CodeDQY · Cardiovascular
Decision DateJul 28, 2005
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 870.1250
Device ClassClass 2
AttributesTherapeutic

Indications for Use

This catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, and renal arteries. These catheters are not designed to be used in the coronary arteries.

Device Story

Mini Ghost PTA Catheter is a coaxial catheter for percutaneous transluminal angioplasty (PTA) of small peripheral vessels. Device features 3.5F polyamide outer shaft with distally mounted non-compliant balloon; accommodates 0.018" guidewire. Radiopaque platinum marker bands under balloon shoulders facilitate placement via fluoroscopy. Operated by physicians in clinical settings. Device is inserted into femoral, iliac, or renal arteries to dilate stenotic vessels. Output is mechanical dilation of vessel lumen. Benefits include minimally invasive treatment of peripheral arterial disease. Device is supplied sterile.

Clinical Evidence

Bench testing only. No clinical data provided.

Technological Characteristics

Coaxial catheter; 3.5F polyamide/Pebax shaft; PES2 non-compliant balloon; platinum radiopaque marker bands. Compatible with 0.018" guidewire. Sterilized device. No software or electronic components.

Indications for Use

Indicated for Percutaneous Transluminal Angioplasty (PTA) of femoral, iliac, and renal arteries. Contraindicated for use in coronary arteries.

Regulatory Classification

Identification

A percutaneous catheter is a device that is introduced into a vein or artery through the skin using a dilator and a sheath (introducer) or guide wire.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## 510(K) SUMMARY June 27, 2005 Submitted By: NuMED, Inc. , 2880 Main St., Hopkinton, NY 12965 (Ph) 315-328-4491 Contact Person: Nichelle LaFlesh Device Name: NuMED Mini Ghost PTA Catheter; 21 CFR 870.1250 - Percutaneous Catheter Predicate Devices: NuMED Z-MED PTA Catheter Device Description: The Mini Ghost PTA Catheter is a coaxial catheter indicated for PTA of small vessels outside of the heart. This catheter is not intended for use in the corronary arteries. The catheter consists of a 3.5F polyamide outer shaft with a distally mounted balloon. The catheter terminates proximally in a bifurcated Y sleeve with mounted bandem. For the balloon and the guidewire. The inner tubing extends through the balloon and accommodates a 0.018" guidewire. The lumen has radiopaque platinum marker bands under the balloon shoulders for placement using fluoroscopy. The catheter balloon diameter is stamped onto the Y sleeve and the balloon extension is labeled with balloon diameter x balloon length x introducer size x shaft size x usable length x guidewire size and the catheter lot number. The catheter is packaged in a polyethylene sheath and is double packed in two heat sealed Tyvek pouches. ### Biocompatibility Testing: The materials used in the NuMED Mini Ghost PTA Catheter are the same as those used in the already approved Z-MED PTA Catheter (510(k) #K931009) which were tested for biocompatibility in compliance with the Tripartite Biocompatibility Guidance for Medical Devices. Test results indicate that all materials demonstrate the biocompatibility of the NuMED catheter and are on file at NuMED, Inc. #### Laboratory (Bench) Testing: All bench testing was performed in accordance with GMP's and the results are kept on file at NuMED, Inc. #### Intended Use: This catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, and renal arteries. These catheters are not designed to be used in the coronary arteries. {1}------------------------------------------------ | Comparison Information: | | | |-------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | MODEL: | NUMED Z-MED PTA<br>CATHETER | NUMED MINI GHOST PTA<br>CATHETER | | Indications: | This catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, and renal arteries. These catheters are not designed to be used in the coronary arteries. | This catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the femoral, iliac, and renal arteries. These catheters are not designed to be used in the coronary arteries. | | Shaft Size: | 5F - 9F | 3.5F | | Guidewire Size: | 0.025" and 0.035" | 0.018" | | Usable Length: | 75cm - 120cm | 40cm - 120cm | | Balloon Diameter: | 2mm - 25mm | 2mm - 6mm | | Balloon Length: | 1cm - 15cm | 2cm - 10cm | | Materials: | Shaft: Pebax<br>Balloon: PES2<br>Image Band: Platinum | Shaft: Pebax<br>Balloon: PES2<br>Image Band: Platinum | | Construction: | Coaxial construction with<br>distally mounted non-compliant<br>balloons. | Coaxial construction with<br>distally mounted non-compliant<br>balloon. | . {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the seal of the Department of Health & Human Services - USA. The seal is circular and contains the department's name around the perimeter. In the center is an abstract symbol that resembles an eagle or bird in flight, composed of three stylized, curved lines. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUL 2 8 8 2005 NuMED, Inc. c/o Ms. Nichelle R. LaFlesh Regulatory Affairs Manager 2880 Main St Hopkinton, NY 12965 Re: K051343 Mini Ghost PTA Catheter Regulation Number: 21 CFR 870.1250 Regulation Name: Percutaneous catheter Regulatory Class: Class II Product Code: DQY Dated: June 27, 2005 Received: June 28, 2005 Dear Ms. LaFlesh: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate for assessment to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must {3}------------------------------------------------ Page 2 - Ms. Nichelle R. LaFlesh comply with all the Act's requirements, including, but not limited to: registration and listing (21 comply will an the Act 3 requirements, nieraally, and manufacturing practice requirements as set as a CFR Part 807), labeling (21 CFR Part 820); and if applicable, the electronic form in the quality systems (Sections 531-542 of the Act); 21 CFR 1000-1050. product lauation control promotio (Seting your device as described in your Section 510(k) This letter will anow you to oegin management of your device of your device to a legally premarket notification: "The PDF intember of your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please If you desire specific advice 101 your at (240) 276-0120. Also, please note the regulation entitled, Comaci the Office of Complaners and station" (21CFR Part 807.97). You may obtain Misolaliuning by reference to premation on your responsibilities under the Act from the Division of Small biller general informational and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, R. Vachner Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # Indications for Use 510(k) Number (if known): Device Name: Mini Ghost PTA Catheter Indications For Use: - This catheter is recommended for Percutaneous Transluminal Angioplasty (PTA) of the l femoral, iliac, and renal arteries. These catheters are not designed to be used in the coronary arteries. ,, Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over-The-Counter Use (21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Durra P. V. Ames (Division Sign-Off) Division of Cardiovascular Devices 510(k) Number_K 05 Page 1 of 1
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...