CHEETAH I.V.D.S., MODEL 2002P

K023370 · Cheetah Medical, Inc. · DQK · Dec 24, 2002 · Cardiovascular

Device Facts

Record IDK023370
Device NameCHEETAH I.V.D.S., MODEL 2002P
ApplicantCheetah Medical, Inc.
Product CodeDQK · Cardiovascular
Decision DateDec 24, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 870.1425
Device ClassClass 2

Indications for Use

The Cheetah Integrated Vascular Diagnostic System (I.V.D.S.) is a non-invasive tool intended to detect blood wave front (BWF) delay.

Device Story

Cheetah I.V.D.S. is a portable, non-invasive, 4-channel blood wave front (BWF) detector with a time marker channel. Input consists of signals from 2 finger probes, 2 toe probes, and time marker leads placed on wrists and legs. Device measures time lag between peripheral BWF and peak of R-wave on time marker signal. System comprises probes connected to a standard laptop computer via an analog-to-digital converter. Software analyzes acquired data and generates a printout of the pulse wave reaching the periphery. Used in clinical settings to assist healthcare providers in vascular assessment; provides quantitative time lag measurements to aid clinical decision-making regarding vascular status.

Clinical Evidence

Clinical study performed to verify equivalence of the Cheetah Time Marker to the Autocorr Time Marker. Results showed no statistically significant difference between automatically calculated time lag measurements of the Cheetah I.V.D.S. and the output of the predicate Autocorr device.

Technological Characteristics

Portable system using 4-channel BWF detection and time marker leads. Includes finger/toe probes, analog-to-digital converter, and standard laptop computer. Connectivity via analog-to-digital interface. Complies with IEC 60601-1, CAN/CSA-C22.2 No.601.1.2, CISPR 11, and UL 2601-1 standards.

Indications for Use

Indicated for the detection of blood wave front (BWF) delay in patients requiring non-invasive vascular diagnostic assessment.

Regulatory Classification

Identification

A programmable diagnostic computer is a device that can be programmed to compute various physiologic or blood flow parameters based on the output from one or more electrodes, transducers, or measuring devices; this device includes any associated commercially supplied programs.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ ## 510(K) SUMMARY # CHEETAH I.V.D.S. 510(k) Number K_0233 FO ## Applicant's Name: Cheetah Medical, Inc. 1201 Market Street, Suit 1600 Wilmington, Delaware 19801, USA 1 (302) 571-1128 or Tel: 1 (302) 777-6571 1 (302) 656-8865 Fax: ### Contact Person: Ms. Sharon McGrenrey Cheetah Medical, Inc. 1201 Market Street, Suit 1600 Wilmington, Delaware 19801, USA 1 (302) 571-1128 or Tel: 1 (302) 777-6571 1 (302) 656-8865 Fax: ## Date Prepared: September 2002 ## Trade Name: Cheetah I.V.D.S. Model 2002P ## Classification Name: Programmable Diagnostic Computer ## Classification: Programmable Diagnostic Computers are class II devices (Product Code DQK). #### Predicate Device: The Cheetah I.V.D.S. is substantially equivalent to the Autocorr® Plus (#3404) Pulse Oximeter/ECG Monitor (BCI INTL., INC.), cleared under K981939. #### Performance Standards: No performance standards have been established for such a device under Section 514 of the Federal Food, Drug, and Cosmetic Act. However, the Cheetah I.V.D.S. complies with the following voluntary standards: - IEC 60601-1-2:1993 - - CAN/CSA-C22.2 No.601.1.2-94 (R1999) - - CISPR 11:1997+A1:1999 class A - {1}------------------------------------------------ - FDA reviewer guidance for premarket notification submissions, November 1993: clauses 7(ii)(c)(1), 7(ii)(c)(2), 7(ii)(c)(3), 7(ii)(d), 7(ii)(f); - EN60601-1:1990+A1:1992+A2:1995+A13:1996 ー - IEC 60601-1:1988+A1:1991+A2:1995 - - -UL 2601-1:1997 - CSA-C22.2 No 601.1 - ## Intended Use / Indication for Use: The Cheetah Integrated Vascular Diagnostic System (I.V.D.S.) is a non-invasive tool intended to detect blood wave front (BWF) delay. ## Device Description: The Cheetah I.V.D.S. is a portable, non-invasive, 4-Channel Cheetah - Blood Wave Front (BWF) detector, with an additional Time Marker channel. The Cheetah channel is intended to measure the time lag between the start of the blood wave front in the peripheral vascular system and the peak of the R-wave on the time marker signal. The Cheetah I.V.D.S. consists of 2 finger probes, 2 toe probes and time marker leads placed on the subject's wrists and legs. The probes are connected to a computer that analyses and presents a print out of the pulse wave as it reaches the periphery. In addition, the Cheetah I.V.D.S. comprises standard Laptop computer connected to conventional analog-to-digital converter, which is used for the analysis and presentation of the acquired data. ## Substantial Equivalence: The design of the Cheetah I.V.D.S. utilizes currently available technology found in legally marketed devices. The major difference between the new device and the predicate device is the addition of electronic circuits for detection of peripheral BWF (one for each limb) and addition of software that calculates and compares the time lags between the cardiac Time Marker and the BWF. Testing was done to ensure that the Cheetah I.V.D.S. will perform safely and accurately within the environment for which it is to be marketed. Safety testing was conducted in accordance with the following guidance and standards: IEC 60601-1-2:1993; CAN/CSA-C22.2 No.601.1.2-94 (R1999); CISPR 11:1997+A1:1999 class A; FDA reviewer guidance for premarket notification submissions. November 1993: clauses 7(ii)(c)(1), 7(ii)(c)(2), 7(ii)(c)(3), 7(ii)(d), EN60601-1:1990+A1:1992+A2:1995+A13:1996; 60601-7(ii)(f): 1:1988+A1:1991+A2:1995; UL 2601-1:1997 and CSA-C22.2 No 601.1. The results demonstrated that the Cheetah I.V.D.S. meets the relevant requirements of the abovementioned guideline and standards and that it performs within its specifications and functional requirements. {2}------------------------------------------------ In addition, verification and validation testing was performed to evaluate the performance of the Cheetah software. Test results showed that the Cheetah software performs according to its specifications. Finally, a clinical study was performed to verify that the Cheetah Time Marker is substantially equivalent to a legally marketed Autocorr Time Marker. Study results showed that using the same Time markers, there is no statistically significant difference between the automatically calculated time lag measurements of the Cheetah I.V.D.S. and the output of the Autocorr device. Based on the technological similarity of the Cheetah to its predicate device, and following the evaluation of the differences between the systems, we conclude that the Cheetah I.V.D.S. is substantially equivalent to its predicate device cited above without raising new safety and/or effectiveness issues. {3}------------------------------------------------ Image /page/3/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized design featuring three abstract human profiles facing to the right, stacked on top of each other. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JAN 1 6 2003 Cheetah Medical, Inc. c/o Ms. Sharon McGrerey 1201 Market Street, Suite 1600 Wilmington, Delaware 19801 Re: K023370 Trade Name: Cheetah Integrated Vascular Diagnostic System (I.V.D.S) Regulation Number: 21 CFR 870.1425 Regulation Name: Programmable Diagnostic Computer Regulatory Class: Class II (two) Product Code: DQK Dated: October 2, 2002 Received: October 8, 2002 Dear Ms. McGrerey: This letter corrects our substantially equivalent letter of December 24, 2002, regarding the contact person and address. We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent [{for the indications for use stated in the enclosure)] to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {4}------------------------------------------------ Page 2 - Ms. Sharon McGrerey Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to continue marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally Part 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4646. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at their toll free number (800) 638-2041 or at (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Bram D. Zuckerman, M.D. Director Division of Cardiovascular Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ # INDICATIONS FOR USE STATEMENT K023370 510(k) Number (if known): . Cheetah I.V.D.S Device Name: in ## Indications for Use: The Cheetah Integrated Vascular Diagnostic System (I.V.D.S) is a non-invasive tool intended to detect blood wave front (BWF) delay. . Concurrence of CDRH, Office of Device Evaluation (ODE) Jevision Sign-l # ivision of Caraluva 170 ි 10(k) Number . 510(k) Number_ (PLEASE DO NOT WRITE BELOW THIS LINE -CONTINUE ON ANOTHER PAGE IF NEEDED) ﻟﻠ Prescription Use (Per 21 CFR 801.109) OR Over the Counter Use - - - - 8-7
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...