DJC · Thin Layer Chromatography, Methamphetamine

Clinical Toxicology · 21 CFR 862.3610 · Class 2

Overview

Product CodeDJC
Device NameThin Layer Chromatography, Methamphetamine
Regulation21 CFR 862.3610
Device ClassClass 2
Review PanelClinical Toxicology
3rd-Party ReviewableYes

Identification

A methamphetamine test system is a device intended to measure methamphetamine, a central nervous system stimulating drug, in serum, plasma, and urine. Measurements obtained by this device are used in the diagnosis and treatment of methamphetamine use or overdose.

Classification Rationale

Class II (special controls). A methamphetamine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (e.g., programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Special Controls

*Classification.* Class II (special controls). A methamphetamine test system is not exempt if it is intended for any use other than employment or insurance testing or is intended for Federal drug testing programs. The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9, provided the test system is intended for employment and insurance testing and includes a statement in the labeling that the device is intended solely for use in employment and insurance testing, and does not include devices intended for Federal drug testing programs (*e.g.,* programs run by the Substance Abuse and Mental Health Services Administration (SAMHSA), the Department of Transportation (DOT), and the U.S. military).

Recent Cleared Devices (20 of 31)

Showing 20 most recent of 31 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K253705Healgen® Accurate Oral Fluid Drug TestHealgen Scientific,, LLCMar 16, 2026SESE
K240287LYHER® Oral fluid Multi-Drug Test Kit (Cube)Hangzhou Laihe Biotech Co., Ltd.Mar 18, 2025SESE
K180878BIO-VENTURE Rapid Amphetamine Test Cassette for OTC Use, BIO-VENTURE Rapid Oxazepam Test Cassette for OTC Use, BIO-VENTURE Rapid Cocaine Test Cassette for OTC Use, BIO-VENTURE Rapid Methamphetamine Test Cassette for OTC Use, BIO-VENTURE Rapid Morphine Test Cassette for OTC Use, BIO-VENTURE Rapid Marijuana Test Cassette for OTC Use, BIO-VENTURE Rapid Amphetamine Test Cassette for Rx Use, BIO-VENTURE Rapid Oxazepam Test Cassette for Rx Use, BIO-VENTURE Rapid Cocaine Test Cassette for RxShanghai Venture Bio-Tech Co., Ltd.Dec 17, 2018SESE
K181305OralTox Oral fluid Drug TestPremier Biotech, Inc.Sep 20, 2018SESE
K171403OralTox Oral Fluid Drug TestPremier Biotech, Inc.Feb 2, 2018SESE
K161044AssureTech Methamphetamine Tests (Strip, Panel Dip, Quick Cup, Turn-Key Split Cup), AssureTech Phencyclidine Tests (Strip, Panel Dip, Quick Cup, Turn-Key Split Cup), AssureTech Marijuana Tests (Strip, Panel Dip, Quick Cup, Turn-Key Split Cup)Assure Tech. (Hangzhou) Co, Ltd.Jul 6, 2016SESE
K132630WONDFO OXAZEPAM URINE TEST (BZO 200) AND WONDFO METHAMPHETAMINE URINE TEST (MET 300)Guangzhou Wondfo Biotech Co., Ltd.Sep 27, 2013SESE
K080347UNISCAN -DOA SYSTEMTaiwan Unison Biotech, Inc.Oct 9, 2008SESE
K060355ACRO BIOTECH LLC RAPID MDMA URINE TEST, CATALOG MDMA0010000Acro Biotech, LLCAug 7, 2006SESE
K060896MODIFICATION TO ONTRAK TESTCUP II AND ONSITE CUPKITVarian, Inc.Jun 9, 2006SESE
K053033ACRO BIOTECH LLC RAPID METHAMPHETAMINE URINE TEST; CATALOG# MET001000Acro Biotech, LLCJun 6, 2006SESE
K031497AMEDICA DRUG SCREEN MDMA-BAR-BZO-MTD-TCA TESTAmedica Biotech, Inc.Oct 17, 2003SESE
K022388STARTOX DRUG OF ABUSE SCREENING TEST (4)Starplex Scientific, Inc.Feb 27, 2003SESE
K022501INSTANT-VIEW MDMA (ECSTASY, XTC) URINE TESTAlfa Scientific Designs, Inc.Nov 13, 2002SESE
K022141VERDICT-IIMedtox Diagnostics, Inc.Jul 30, 2002SESE
K011185PSYCHEMEDICS RIA METHAMPHETAMINE AND MDMA ASSAYPsychemedics Corp.Jan 24, 2002SESE
K013180RAPIDONE-ECSTASY TESTAmerican Bio Medica Corp.Nov 26, 2001SESE
K010226VERDICT -II METHAMPHETAMINEMedtox Diagnostics, Inc.Jun 1, 2001SESE
K002265BRANAN MEDICAL CORPORATION MONITECT METHAMPHETAMINE DRUG SCREEN TESTBranan Medical CorporationNov 27, 2000SESE
K002587BRANAN MEDICAL CORPORATION MONITECT METHAMPHETAMINE 500 DRUG SCREEN TESTBranan Medical CorporationNov 22, 2000SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...