SMARTPREP2 CENTRIFUGE SYSTEM

K052925 · Harvest Technologies, Corp. · JQC · Jan 4, 2006 · Clinical Chemistry

Device Facts

Record IDK052925
Device NameSMARTPREP2 CENTRIFUGE SYSTEM
ApplicantHarvest Technologies, Corp.
Product CodeJQC · Clinical Chemistry
Decision DateJan 4, 2006
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.2050
Device ClassClass 1
AttributesTherapeutic

Intended Use

The SmartPReP2 Centrifuge System is intended to be used in the clinical laboratory or intraoperatively at point-of-care for the safe and rapid preparation of platelet poor plasma and platelet concentrate from a small sample of blood and for preparation of a cell concentrate from bone marrow.

Device Story

SmartPReP2 Centrifuge System is a table-top, self-decanting swinging bucket centrifuge; used in clinical laboratories or intraoperatively at point-of-care. Device processes blood samples or bone marrow aspirate using a dedicated Bone Marrow Procedure Pack and Process Disposable. Centrifugation separates blood/marrow components to produce platelet poor plasma, platelet concentrate, or bone marrow cell concentrate. System operated by clinical staff to prepare autologous concentrates for clinical use. Benefits include rapid, safe preparation of cellular concentrates from small patient samples.

Clinical Evidence

Bench testing only. Biocompatibility and performance testing established the system is suitable for the intended use.

Technological Characteristics

Table-top, self-decanting swinging bucket centrifuge. Includes Bone Marrow Procedure Pack and Process Disposable. Mechanical separation principle. No software or electronic algorithm described.

Indications for Use

Indicated for clinical laboratory or intraoperative point-of-care preparation of platelet poor plasma, platelet concentrate from blood, and cell concentrate from bone marrow aspirate.

Regulatory Classification

Identification

General purpose laboratory equipment labeled or promoted for a specific medical use is a device that is intended to prepare or examine specimens from the human body and that is labeled or promoted for a specific medical use.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is an emblem featuring a stylized image of three human profiles facing to the right, stacked one behind the other. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 January 13, 2016 Harvest Technologies Corp. Mr. John D. Bonasera Director of Regulatory Affairs 40 Grissom Road Suite 100 Plymouth, MA 02360 Re: K052925 Trade/Device Name: SmartPReP2 Centrifuge System Regulation Number: 21 CFR 880.5860 Regulation Name: Piston syringe Regulatory Class: Class II Product Code: FMF, JQC Dated: October 14, 2005 Received: October 18, 2005 Dear Mr. Bonasera: This letter corrects our substantially equivalent letter of January 4, 2006. We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act {1}------------------------------------------------ or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Parts 801 and 809); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Parts 801 and 809), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, ## Leonthena R. Carrington -S Leonthena R. Carrington, MS, MBA, MT(ASCP) Director Division of Immunology and Hematology Devices Office of In Vitro Diagnostics and Radiological Health Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ ## INDICATIONS FOR USE STATEMENT 510(k) Number if Known: K052925 Device Name: SmartPReP2 Centrifuge System Indications for Use: The SmartPReP2 Centrifuge System is intended to be used in the clinical laboratory or intraoperatively at point-of-care for the safe and rapid preparation of platelet poor plasma and platelet concentrate from a small sample of blood and for preparation of a cell concentrate from bone marrow. Prescription Use/ (Part 21 CFR 801 Subpart D) : AND/OR Over-The-Counter Use (21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE OF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Robert M. Becker Division Sign-Off Page / of / l 13 Office of In Vitro Diagnostic Device Evaluation and Safety K052925 {3}------------------------------------------------ JAN 4 2006 K052925 ## 510(k) Summary for the SmartPReP2 Centrifuge System for Bone Marrow Processing ## Page 1 of 1 Submitter's Name and Address: Harvest Technologies Corp. 40 Grissom Road, Suite 100 Plymouth, MA Phone Number: 508-732-7530 Telefax Number: 503-732-0400 Contact Person: John D. Bonasera, Director, Regulatory Affairs Date Summary Prepared: September 20, 2005 Device Trade Name: SmartPReP2 Centrifuge System Common Name: Centrifuge for Clinical Use Classification Name: General Purpose Laboratory Centrifuge Labeled or Promoted for a Specific Medical Use Regulation Number: 21 CFR 862.2050 Substantial Equivalence: The proposed device is substantially equivalent to SmartPReP Centrifuge System described in K991430 and other table-top centrifuges previously cleared by the FDA via the 510(k) Notification process. Device Description: The Harvest Technologies SmartPReP2 System includes a table-top, self-decanting swinging bucket centrifuge. The SmartPReP2 Bone Marrow Procedure Pack includes a Process Disposable and other accessories to allow for separation of cells from bone marrow aspirate. Intended Use: The SmartPReP2 Centrifuge System is intended to be used in the clinical laboratory or intraoperatively at pointof-care for the safe and rapid preparation of platelet poor plasma and platelet concentrate from a small sample of blood and for preparation of a cell concentrate from bone marrow. Technological Characteristics: The proposed device has the same technological characteristics and is similar in design and configuration compared with the predicate devices. Performance Testing: Results of biocompatibility and performance testing have established that the SmartPReP2 System is suitable for the intended use indicated.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...