SYNCHRON LX20 CLINICAL SYSTEMS, CREATININE TEST SYSTEMS

K071277 · Beckman Coulter, Inc. · CGX · Jun 1, 2007 · Clinical Chemistry

Device Facts

Record IDK071277
Device NameSYNCHRON LX20 CLINICAL SYSTEMS, CREATININE TEST SYSTEMS
ApplicantBeckman Coulter, Inc.
Product CodeCGX · Clinical Chemistry
Decision DateJun 1, 2007
DecisionSESE
Submission TypeSpecial
Regulation21 CFR 862.1225
Device ClassClass 2

Indications for Use

CREm reagent, when used in conjunction with SYNCHRON LX® System(s), UniCel® DxC 800 System and SYNCHRON® Systems AQUA CAL 1 and 2, is intended for the quantitative determination of Creatinine concentration in human serum, plasma or urine. The Beckman Coulter AQUA CAL 1, 2, and 3 are intended for use on SYNCHRON LX® and UniCel® DxC Systems for the calibration of Sodium, Potassium, Chloride, Urea Nitrogen, Urea, Glucose Creatinine, Calcium, Carbon Dioxide, and Phosphorus.

Device Story

The SYNCHRON LX20 Clinical System is an automated clinical chemistry analyzer. It measures creatinine concentration in human serum, plasma, or urine using the Jaffe rate method. The system injects a sample into a reaction cup containing CREm reagent (picric acid); absorbance is measured at 520 nm between 19 and 25 seconds post-injection. Calibration is performed using aqueous-based AQUA Cal 1 and 2, which are traceable to NIST reference materials. The device is operated by laboratory personnel in a clinical setting. Output consists of quantitative creatinine concentration values, which clinicians use to diagnose and monitor renal disease and dialysis. This specific submission involves a modification to the chemistry database calibrator set points, updated via correlation to Isotope Dilution Mass Spectrometry (IDMS).

Clinical Evidence

Bench testing only; no clinical data provided. Verification and validation activities performed per design control procedures (21 CFR 820.30) to confirm that modified calibration values meet predetermined acceptance criteria.

Technological Characteristics

Calibration materials (AQUA Cal levels 1 & 2) for creatinine assays. Modification: assigned values traceable to Isotope Dilution Mass Spectrometry (IDMS).

Indications for Use

Indicated for quantitative determination of creatinine in human serum, plasma, or urine to aid in diagnosis and treatment of renal diseases and monitoring of renal dialysis.

Regulatory Classification

Identification

A creatinine test system is a device intended to measure creatinine levels in plasma and urine. Creatinine measurements are used in the diagnosis and treatment of renal diseases, in monitoring renal dialysis, and as a calculation basis for measuring other urine analytes.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} SPECIAL 510(k): Device Modification ODE Review Memorandum (Decision Making Document is Attached) To: THE FILE RE: DOCUMENT NUMBER K071277 This 510(k) submission contains information/data on modifications made to the SUBMITTER'S own Class II, Class III or Class I devices requiring 510(k). The following items are present and acceptable (delete/add items as necessary): 1. The name and 510(k) number of the SUBMITTER'S previously cleared device. (For a preamendments device, a statement to this effect has been provided.) k965240 2. Submitter's statement that the INDICATION/INTENDED USE of the modified device as described in its labeling HAS NOT CHANGED along with the proposed labeling which includes instructions for use, package labeling, and, if available, advertisements or promotional materials (labeling changes are permitted as long as they do not affect the intended use). 3. A description of the device MODIFICATION(S), including clearly labeled diagrams, engineering drawings, photographs, user's and/or service manuals in sufficient detail to demonstrate that the FUNDAMENTAL SCIENTIFIC TECHNOLOGY of the modified device has not changed. This change was for : The values assigned to AQUA Cal levels 1 & 2 will be modified to be traceable to Isotope Dilution Mass Spectrometry (IDMS) for creatinine recovery, instead of being traceable to NIST materials. 4. Comparison Information (similarities and differences) to applicant's legally marketed predicate device including, labeling, intended use, physical characteristics, and performance characteristics. 5. A Design Control Activities Summary which includes: a) Identification of Risk Analysis method(s) used to assess the impact of the modification on the device and its components, and the results of the analysis FMEA b) Based on the Risk Analysis, an identification of the verification and/or validation activities required, including methods or tests used and acceptance criteria to be applied c) A declaration of conformity with design controls. The declaration of conformity should include: i) A statement signed by the individual responsible, that, as required by the risk analysis, all verification and validation activities were performed by the designated individual(s) and the results demonstrated that the predetermined acceptance criteria were met, and ii) A statement signed by the individual responsible, that the manufacturing facility is in conformance with design control procedure requirements as specified in 21 CFR 820.30 and the records are available for review. 6. A Truthful and Accurate Statement, a 510(k) Summary or Statement and the Indications for Use Enclosure (and Class III Summary for Class III devices). The labeling for this modified subject device has been reviewed to verify that the indication/intended use for the device is unaffected by the modification. In addition, the submitter's description of the particular modification(s) and the comparative information between the modified and unmodified devices demonstrate that the fundamental scientific technology has not changed. The submitter has provided the design control information as specified in The New 510(k) Paradigm and on this basis, I recommend the device be determined substantially equivalent to the previously cleared (or their preamendment) device.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...