CLEVER CHEK BLOOD GLUCOSE MONITORING SYSTEM; ACHTUNG BLOOD GLUCOSE MONITORING SYSTEM
Device Facts
| Record ID | K090185 |
|---|---|
| Device Name | CLEVER CHEK BLOOD GLUCOSE MONITORING SYSTEM; ACHTUNG BLOOD GLUCOSE MONITORING SYSTEM |
| Applicant | Taidoc Technology Corporation |
| Product Code | NBW · Clinical Chemistry |
| Decision Date | Apr 24, 2009 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 862.1345 |
| Device Class | Class 2 |
| Attributes | Pediatric |
Indications for Use
The Achtung TD-4207 no code/Clever Chek TD-4209 one-code/Clever Chek TD-4222 no code/Clever Chek TD-4225 no code/Clever Chek TD-4226 one-code Blood Glucose Monitoring System is intended for use in the quantitative measurement of glucose in fresh capillary whole blood from the finger and the following alternative sites: the palm, the forearm, the upper-arm, the calf and the thigh. It is intended for use by healthcare professionals and people with diabetes mellitus at home as an aid in monitoring the effectiveness of diabetes control program. It is not intended for the diagnosis of or screening for diabetes mellitus, and is not intended for use on neonates. The alternative site testing in above systems can be used only during steady-state blood glucose conditions.
Device Story
Device modification involving integrated circuit upgrade; increased CPU bit size, ROM, RAM, and ADC channels. Modification maintains fundamental scientific technology of previously cleared device. Intended use and labeling remain unchanged. Design control activities, including risk analysis and verification/validation, performed to confirm performance meets acceptance criteria.
Clinical Evidence
No clinical data provided in the summary document; substantial equivalence established via bench testing and comparison to predicate technology.
Technological Characteristics
Integrated circuit hardware upgrade; increased CPU bit size, ROM, RAM, and ADC channels. Fundamental scientific technology unchanged from predicate.
Indications for Use
Indicated for quantitative glucose measurement in fresh capillary whole blood (finger, palm, forearm, upper-arm, calf, thigh) for healthcare professionals and patients with diabetes mellitus to monitor glycemic control. Contraindicated for neonates and for diabetes diagnosis or screening. Alternative site testing restricted to steady-state glucose conditions.
Regulatory Classification
Identification
A glucose test system is a device intended to measure glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.
Special Controls
*Classification.* Class II (special controls). The device, when it is solely intended for use as a drink to test glucose tolerance, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.
Related Devices
- K073494 — CLEVER CHEK BLOOD GLUCOSE MONITORING SYSTEM, MODELS TD-4209, -4222, -4225 AND -4226 AND ACHTUNG BLOOD GLUCOSE MONITORING · Taidoc Technology Corporation · Apr 2, 2008
- K042005 — ACHTUNG TD-4207, CLEVER CHEK TD-4209, CLEVER CHEK TD-4222 · Taidoc Technology Corporation · Aug 27, 2004
- K082482 — FORA TD-4251/U-RIGHT TD-4252/U-RIGHT TD-4254 BLOOD GLUCOSE MONITORING SYSTEM, MODEL TD-4251/TD-4252A/TD-4252B/TD-4254 · Taidoc Technology Corporation · Jan 30, 2009
- K083570 — U-RIGHT TD-4249/U-RIGHT TD-4250 BLOOD GLUCOSE MONITORING SYSTEM · Taidoc Technology Corporation · Mar 11, 2009
- K063212 — CLEVER CHEK TD-4231 AND TD-4223 BLOOD GLUCOSE MONITORING SYSTEM · Taidoc Technology Corporation · Nov 22, 2006