ELECSYS CALCHECK FSH

K964829 · Boehringer Mannheim Corp. · JIX · Dec 16, 1996 · Clinical Chemistry

Device Facts

Record IDK964829
Device NameELECSYS CALCHECK FSH
ApplicantBoehringer Mannheim Corp.
Product CodeJIX · Clinical Chemistry
Decision DateDec 16, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1150
Device ClassClass 2

Indications for Use

The Boehringer Mannheim Elecsys CalCheck FSH is used to verify the calibration assignment for the Boehringer Mannheim Elecsys FSH assay.

Device Story

Calibration verification material; used to verify calibration assignment for Elecsys FSH assay. Manufactured using human serum albumin, follicle stimulating hormone, and stabilizers. Analyte spiked into matrix to specific concentration levels. Quality controlled against Enzymun FSH assay kit calibrators. Used in clinical laboratory settings by laboratory personnel. Provides verification of assay calibration accuracy.

Clinical Evidence

Bench testing only. Evaluated for value assignment and stability.

Technological Characteristics

Matrix: human serum albumin, follicle stimulating hormone, stabilizers. Analyte spiked to specific concentration levels. Quality control performed against Enzymun FSH assay kit calibrators.

Indications for Use

Indicated for use as a calibration verification material for the Boehringer Mannheim Elecsys FSH assay to verify calibration assignment.

Regulatory Classification

Identification

A calibrator is a device intended for medical purposes for use in a test system to establish points of reference that are used in the determination of values in the measurement of substances in human specimens. (See also § 862.2 in this part.)

Special Controls

*Classification.* Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 862.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} 12/12/96 12:43 510 574 8523 003/006 K964829 DEC 16 1996 # 510(k) Summary | Introduction | According to the requirements of 21 CFR 807.92, the following information provides sufficient detail to understand the basis for a determination of substantial equivalence. | | --- | --- | | 1. Submitter name, address, contact | Boehringer Mannheim Corporation 2400 Bisso Lane Concord, CA 94524-4117 (510) 674-0690 extension 8413 Fax number: (510) 687-1850 Contact Person: Yvette Lloyd Date Prepared: December 12, 1996 | | 2. Device Name | Proprietary name: Elecsys CalCheck FSH Common name: Calibration Verification Material Classification name: Single (specified) analyte controls (assayed + unassayed) | | 3. Predicate device | The Boehringer Mannheim Elecsys CalCheck FSH is substantially equivalent to the Tosoh Medic AIA Pack for FSH. (K924863) | | 4. Device Description | The Boehringer Mannheim Elecsys CalCheck FSH are manufactured using human serum albumin, follicle stimulating hormone, and stabilizers. The analyte is appropriately spiked into the calcheck matrix to the correct calcheck concentration levels. The calcheck are in process checked and quality controlled against the Enzymun® FSH assay kit calibrators (prepared using a similar procedure). | Continued on next page {1} 12/12/96 12:44 510 674 8523 SMC CONCORD 004/006 # 510(k) Summary, Continued 5. Intended use The Boehringer Mannheim Elecsys CalCheck FSH is used to verify the calibration assignment for the Boehringer Mannheim Elecsys FSH assay. 6. Comparison to predicate device. **Performance Characteristics:** - The Elecsys® CalCheck™ FSH were evaluated for value assignment and stability. 3
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...