The test is designed for the qualitative detection of hCG in human unine and serum as an early indication of pregnancy. This test is for use in clinical laboratories by health care professionals.
Device Story
Advantage hCG Test is an immunochromatographic in vitro assay. It detects human chorionic gonadotropin (hCG) in urine and serum samples. Used in clinical laboratories by healthcare professionals for early pregnancy detection. The test utilizes specific antibodies to identify hCG at concentrations of 20ng/mL or greater. Results provide qualitative confirmation of pregnancy status to assist clinical decision-making.
Clinical Evidence
Bench testing only. Comparative study evaluated 100 serum samples (51 positive, 49 negative) and 105 urine samples (40 positive, 65 negative) from pregnant and non-pregnant women. Results showed 100% correlation with the predicate device. Sensitivity and specificity are comparable to the predicate.
Technological Characteristics
Immunochromatographic assay; lateral flow format. Detects hCG in human urine and serum. Sensitivity threshold: 20ng/mL. No electronic components, software, or external energy sources required.
Indications for Use
Indicated for qualitative detection of hCG in human urine and serum for early pregnancy detection in clinical laboratory settings by healthcare professionals.
Regulatory Classification
Identification
A human chorionic gonadotropin (HCG) test system is a device intended for the early detection of pregnancy is intended to measure HCG, a placental hormone, in plasma or urine. A human chorionic goadotropin (HCG) test system is a device intended for any uses other than early detection of pregnancy (such as an aid in the diagnosis, prognosis, and management of treatment of persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or urine.
Predicate Devices
PS-Unit Cassette/Serum and Urine Combo HCG
Related Devices
K020438 — SAS VALUE HCG · Sa Scientific, Inc. · Mar 8, 2002
K990684 — MODIFICATION OF SAS SERUM/URINE HCG · Sa Scientific, Inc. · May 10, 1999
K964155 — CONTRAST HCG URINE/SERUM TEST AND RAPID HCG URINE/SERUM TEST · Genzyme Diagnostics · Nov 25, 1996
K061257 — DBEST HCG PANEL TEST KIT · Ameritek USA, Inc. · May 4, 2007
K965116 — ABBOTT TESTPACK PLUS HCG COMBO WITH OBC · Abbott Laboratories · Feb 20, 1997
Submission Summary (Full Text)
{0}------------------------------------------------
#### 3 2000 FEB
# 510(k) Summary
This summary of 510(k) safety and effectiveness information is being submitted in accordance with the requirements of the SMDA 1990 and 21 CFR Part 807.92.
The assigned 510(k) number is K994227
1. Date of summary: January 31, 2000
- Advantage Diagnostics Corporation 2. Submitted by: 2440 Leghorn Street Mountain View CA, 94043
- Advantage hCG Test (Urine/Serum) 3. Device Name:
4. Device Classification: Class II, 862.1155 Product Code JHI
5. Device description: The Advantage hCG Test (Urine/Serum) is an immunochromatographic based one step in vitro test.
6. Intended Use: The test is designed for the qualitative detection of hCG in human unine and serum as an early indication of pregnancy. This test is for use in clinical laboratories by health care professionals.
7. Substantial Equivalence: The Advantage hCG Test (Urine/Serum) was found substantially equivalent to the PS-Unit Cassette/Serum and Urine Combo HCG manufactured by International Newtech Development, Inc. Both products are immunoassays and use specific antibodies to detect the hQG in human urine and serum. The sensitivity of the tests are similar, the Advantage hCG Test detects hCG in serum and urine, at 20ng/mL or greater while the prodicate device detects hCG in serum and urine at concentrations greater than 20ng/mL. The tests demonstrated 100% correlation when 100 serum (51 positive and 49 negative) and 105 urine samples (40 positive and 65 negative) from pregnant and non pregnant women were evaluated and compared. The tests are similar in sensitivity, specificity and accuracy.
## Conclusion:
The Advantage hCG Test (Urine /Serum) and the PS-Unit Cassette/Serum and Urine Combo HCG are substantially equivalent in performance characteristics. The correlation of the two tests was 100%.
{1}------------------------------------------------
Image /page/1/Picture/1 description: The image is a black and white logo for the Department of Health & Human Services - USA. The logo features a stylized symbol resembling a person with outstretched arms, composed of three curved lines. The symbol is enclosed within a circular border, with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter of the circle. The text is in uppercase letters and is evenly spaced around the circle.
Food and Drug Administration 2098 Gaither Road Rockville MD 20850
### FEB 3 2000
Ms. Janis Freestone Director, Regulatory Affairs Advantage Diagnostics Corporation 2440 Leghorn Street Mountain View, California 94043
Re: K994227
> Trade Name: Advantage hCG Test (Urine/Serum) Regulatory Class: II Product Code: JHI Dated: December 3, 1999 Received: December 15, 1999
Dear Ms. Freestone:
We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the Current Good Manufacturing Practice requirements, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic QS inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal laws or regulations.
{2}------------------------------------------------
# Page 2
This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsma/dsmamain.html".
Sincerely yours,
Steven Sutman
Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{3}------------------------------------------------
510k Number: K994227
Device Name: Advantage hCG Test (Urine/Serum)
Indications for Use:
The Advantage hCG Test (Urine/Serum) is a qualitative, rapid immunochromatographic assay used to detect the presence of hCG in human urine and serum for the early detection of pregnancy. The test is intended for use in clinical laboratories by health care professionals.
Jean Cooper.
(Division Sign-Off)
Division of Clinical Laboratory Levices
510(k) Number K994227
Concurrence of CDRH, Office of Device Evaluation (ODE)
**Prescription Use** √
(Per 21 CFR 801.109)
OR
Over the counter use
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.