BIOSTRIP HCG I-ONE STEP PREGNANCY TEST ACCUSTRIP HCG 1-ONE STEP PREGNANCY TEST STRIP

K981444 · Princeton BioMeditech Corp. · JHI · Jul 22, 1998 · Clinical Chemistry

Device Facts

Record IDK981444
Device NameBIOSTRIP HCG I-ONE STEP PREGNANCY TEST ACCUSTRIP HCG 1-ONE STEP PREGNANCY TEST STRIP
ApplicantPrinceton BioMeditech Corp.
Product CodeJHI · Clinical Chemistry
Decision DateJul 22, 1998
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 862.1155
Device ClassClass 2

Indications for Use

Immunoassay for in vitro diagnostic use in hospital, clinical laboratories and physicians' offices for the qualitative determination of Human Chorionic Gonadotropin (hCG) in urine for the early detection of pregnancy.

Device Story

BioStrip hCG 1 is a lateral flow immunoassay for qualitative detection of hCG in urine; used for early pregnancy detection. Device is intended for professional use in hospitals, clinical laboratories, and physicians' offices. Principle of operation involves immunochromatographic capture of hCG; visual interpretation of test lines by healthcare provider. Provides rapid diagnostic result to confirm pregnancy status.

Clinical Evidence

No clinical data provided; device is an in vitro diagnostic immunoassay.

Technological Characteristics

Lateral flow immunochromatographic test strip; qualitative detection of hCG in urine; visual readout.

Indications for Use

Indicated for the qualitative detection of human chorionic gonadotropin (hCG) in urine to aid in the early detection of pregnancy. Intended for use in hospital, clinical laboratories, and physicians' offices.

Regulatory Classification

Identification

A human chorionic gonadotropin (HCG) test system is a device intended for the early detection of pregnancy is intended to measure HCG, a placental hormone, in plasma or urine. A human chorionic goadotropin (HCG) test system is a device intended for any uses other than early detection of pregnancy (such as an aid in the diagnosis, prognosis, and management of treatment of persons with certain tumors or carcinomas) is intended to measure HCG, a placental hormone, in plasma or urine.

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/2 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES USA" around the perimeter. Inside the circle is an abstract symbol that resembles an eagle or a stylized human figure. ## JUL 22 1998 Food and Drug Administration 2098 Gaither Road Rockville MD 20850 Jemo Kanq, Ph.D. President Princeton BioMeditech Corporation P.O. Box 7139 Princeton, New Jersey 08543-7139 Re : K981444 Trade Name: BioStrip® hCGI One Step Pregnancy Test Strip Requlatory Class: II Product Code: JHI Dated: June 19, 1998 Received: June 22, 1998 Dear Dr. Kang: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. A substantially equivalent determination assumes compliance with the current Good Manufacturing Practice requirement, as set forth in the Quality System Regulation (QS) for Medical Devices: General regulation (21 CFR Part 820) and that, through periodic (QS) inspections, the Food and Drug Administration (FDA) will verify such assumptions. Failure to comply with the GMP regulation may result in regulatory action. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under sections 531 through 542 of the Act for devices under the Electronic Product Radiation Control provisions, or other Federal Laws or Regulations. {1}------------------------------------------------ ## Page 2 Under the Clinical Laboratory Improvement Amendments of 1988 (CLIA-88), this device may require a CLIA complexity categorization. To determine if it does, you should contact the Centers for Disease Control and Prevention (CDC) at (770)488-7655. This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801 and additionally 809.10 for in vitro diagnostic devices), please contact the Office of Compliance at (301) 594-4588. Additionally, for questions on the promotion and " advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers Assistance at its toll free number (800) 638-2041 or at (301) 443-6597 or at its internet address "http://www.fda.gov/cdrh/dsmamain.html" Sincerely yours, Steven Putman Steven I. Gutman, M.D., M.B.A. Director Division of Clinical Laboratory Devices Office of Device Evaluation Center for Devices and Radioloqical Health Enclosure {2}------------------------------------------------ 510(k) Number (if known): h981444 BioStrip hCG 1 - One Step Pregnancy Test Strip evice Name: __________________________________________________________________________________________________________________________________________________________________ Indications For Use: Immunoassay for in vitro diagnostic use in hospital, Immunousbur ror fries and physicians' offices for the Crimical raboracorios and Phorionic Gonadotropin (hCG) in urine for the early detection of pregnancy. (PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office | of Device Evaluation (ODE) | | |-----------------------------------------|---------| | (Division Sign-Off) | | | Division of Clinical Laboratory Devices | | | 510(k) Number | k981444 | Prescription Use X Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Formal 1-2-96)
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...