ACCESS ESTRADIOL REAGENTS ON THE ACCESS IMMUNOASSAY ANALYZER (33550,33540,33545)
K970126 · Bio-Rad Laboratories, Inc. · CHP · Feb 25, 1997 · Clinical Chemistry
Device Facts
Record ID
K970126
Device Name
ACCESS ESTRADIOL REAGENTS ON THE ACCESS IMMUNOASSAY ANALYZER (33550,33540,33545)
Applicant
Bio-Rad Laboratories, Inc.
Product Code
CHP · Clinical Chemistry
Decision Date
Feb 25, 1997
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 862.1260
Device Class
Class 1
Indications for Use
The ACCESS® Estradiol assay is a paramagnetic particle chemiluminescent immunoassay for the quantitative determination of Estradiol levels in human serum using the ACCESS® Immunoassay System.
Device Story
ACCESS® Estradiol assay; paramagnetic particle chemiluminescent immunoassay; used with ACCESS® Immunoassay Analyzer. Input: human serum samples. Principle: simultaneous assay format using polyclonal rabbit anti-estradiol antibodies for capture and alkaline phosphatase conjugate; chemiluminescent reaction using dioxetane-based substrate. Output: quantitative estradiol concentration. Used in clinical laboratory settings by trained personnel. Results assist clinicians in assessing estradiol levels. Benefits: provides quantitative measurement of estradiol for diagnostic evaluation.
Clinical Evidence
Bench testing only. Precision: within-run CV 2.7-11.6%, total imprecision 5.2-21.1%. Accuracy: spiking recovery 92-106%; dilution recovery mean 105% (SD 7%). Correlation: n=214 samples vs. Abbott IMx, r=0.958, y=-39+0.983x. Analytical sensitivity: 23 pg/ml (95% confidence). Specificity: Estrone sulfate not detectable at 3600 pg/ml; Estriol sulfate cross-reactivity 0.04% at 10,000,000 pg/ml.
Indicated for the quantitative determination of Estradiol levels in human serum for clinical diagnostic purposes.
Regulatory Classification
Identification
An estradiol test system is a device intended to measure estradiol, an estrogenic steroid, in plasma. Estradiol measurements are used in the diagnosis and treatment of various hormonal sexual disorders and in assessing placental function in complicated pregnancy.
Predicate Devices
Abbott IMx® Estradiol Kit
Related Devices
K973743 — ACCESS ESTRADIOL REAGENTS ON THE ACCESS IMMUNOASSAY ANALYZER · Beckman Instruments, Inc. · Oct 31, 1997
K041349 — LUMINESCENT IMMUNOASSAY KIT FOR THE DETECTION OF ESTRADIOL IN SALIVA AND SERUM · Ibl GmbH · Sep 24, 2004
K970386 — ACS ESTADIOL-6 II · Chiron Diagnostics Corp. · Jun 4, 1997
Submission Summary (Full Text)
{0}
K970126
FEB 25 1997
# APPENDIX D - Summary of Safety and Effectiveness Information
## 1. General Information
January 13, 1997
Device Generic Name: Enzyme Immunoassay, Estradiol
Device Trade Name: ACCESS® Estradiol assay
Applicant's Name and Address: Sanofi Diagnostics Pasteur, Inc.
1000 Lake Hazeltine Drive
Chaska, MN 55318
Contact: Robert McCormack, Ph.D.
612-368-1384
## 2. Predicate Device
Abbott IMx® Estradiol Kit
Abbott Laboratories
Diagnostics Division
Abbott Park, IL 94547
## 3. Device Description
The ACCESS® Estradiol reagents and the ACCESS® Immunoassay Analyzer comprise the ACCESS® Immunoassay System for the quantitative determination of Estradiol levels in human serum.
## 4. Indications for Use
The ACCESS® Estradiol assay is a paramagnetic particle chemiluminescent immunoassay for the quantitative determination of Estradiol levels in human serum using the ACCESS® Immunoassay System.
## 5. Comparison of Technological Characteristics
The ACCESS® Estradiol assay and the Abbott IMx® Estradiol Kit are for the measurement of estradiol in human serum. Both tests utilize polyclonal rabbit anti-estradiol antibodies for capture and an alkaline phosphatase conjugate. Both tests use multi-point liquid calibrators. The ACCESS® Estradiol assay uses a dioxetane based chemiluminescent substrate while the Abbott IMx® Estradiol Kit uses 4-methylumbelliferyl phosphate as the substrate. The ACCESS® Estradiol assay measures light production from a chemiluminescent reaction, while the Abbott IMx® Estradiol Kit measures a fluorescent product. The ACCESS® Estradiol assay uses calibrators prepared in a human serum matrix while the Abbott IMx® Estradiol Kit uses calibrators prepared in Tris buffer with protein stabilizers. The ACCESS® Estradiol assay uses a simultaneous assay format while the Abbott IMx® Estradiol Kit uses a sequential assay format.
## 6. Summary of Studies
**Precision studies:** Within run precision ranges from 11.6% CV (117 pg/ml) to 2.7% CV (3041 pg/ml). Total imprecision ranges from 21.1% CV (72 pg/ml) to 5.2% CV (1456 pg/ml).
**Accuracy:** Spiking recovery studies performed by spiking estradiol into ten serum samples results in recovery ranging from 92% to 106%. Dilution recovery studies performed by diluting 18 patient samples containing estradiol 1:2 with Estradiol Calibrator S0 results in a mean recovery of 105% with a standard deviation of 7%.
**Correlation:** A comparison of estradiol values from 214 samples run in both the ACCESS® Estradiol assay and the Abbott IMx® Estradiol Kit test gives the following statistical data: r = 0.958, y = -39 + 0.983x.
**Analytical Sensitivity:** The lowest detectable level of estradiol distinguishable from zero (Estradiol Calibrator S0) with 95% confidence is 23 pg/ml.
**Analytical Specificity:** Estrone sulfate is not detectable when spiked into the S0 calibrator at 3600 pg/ml. Estriol sulfate gives an apparent cross reactivity of 0.04% when spiked into the S0 calibrator at 10,000,000 pg/ml.
## 7. Conclusion
The ACCESS® Estradiol reagents when used with the ACCESS® Immunoassay Analyzer are substantially equivalent to another test for the measurement of estradiol levels now in commercial distribution.
21
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.