ABL90
Device Facts
| Record ID | K111897 |
|---|---|
| Device Name | ABL90 |
| Applicant | Radiometer Medical Aps |
| Product Code | CHL · Clinical Chemistry |
| Decision Date | Jul 19, 2011 |
| Decision | SESE |
| Submission Type | Special |
| Regulation | 21 CFR 862.1120 |
| Device Class | Class 2 |
Indications for Use
The ABL90 FLEX is a portable, automated analyzer that measures pH, blood gases, electrolytes, glucose, lactate and oximetry in heparinized whole blood. The ABL90 FLEX is intended for use by trained technologists, nurses, physicians and therapists. It is intended for use in a laboratory environment, near patient or point-of-care setting. These tests are only performed under a physician's order: pH, pO2 and pCO2 : pH, pCO2 and pO2 measurements are used in the diagnosis and treatment of life-threatening acid-base disturbances. Potassium (cK+): potassium measurements are used to monitor electrolyte balance in the diagnosis and treatment of disease conditions characterized by low or high blood potassium levels. Sodium (cNa+): sodium measurements are used in the diagnosis and treatment of aldosteronism, diabetes insipidus, adrenal hypertension, Addison's disease, dehydration, inappropriate antidiuretic secretion, or other diseases involving electrolyte imbalance. Calcium (cCa2+): calcium measurements are used in the diagnosis and treatment of parathyroid disease, a variety of bone diseases, chronic renal disease and tetany. Chloride (cCI-): chloride measurements are used in the diagnosis and treatment of electrolyte and metabolic disorders such a cystic fibrosis and diabetic acidosis. Glucose (cGlu): glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma. Lactate (cLac): The lactate measurements measure the concentration of lactate in plasma. Lactate measurements are used to evaluate the acid-base status and are used in the diagnosis and treatment of lactic acidosis (abnormally high acidity of the blood.) Total Hemoglobin (ctHb): total hemoglobin measurements are used to measure the hemoglobin content of whole blood for the detection of anemia. sO2: oxygen saturation, more specifically the ratio between the concentration of oxyhemoglobin and oxyhemoglobin plus reduced hemoglobin. FO2Hb: oxyhemoglobin as a fraction of total hemoglobin. FCOHb: carboxyhemoglobin measurements are used to determine the carboxyhemoglobin content of human blood as an aid in the diagnosis of carbon monoxide poisoning. FMetHb: methemoglobin as a fraction of total hemoglobin. FHHb: reduced hemoglobin as a fraction of total hemoglobin. Fraction of Fetal Hemoglobin (FHbF): FHbF indicates the amount of fetal hemoglobin. FHbF is seldom used clinically.
Device Story
Portable, automated blood gas analyzer for point-of-care or laboratory use. Analyzes heparinized whole blood samples via aspiration. Measures pH, pO2, pCO2, electrolytes (K+, Na+, Ca2+, Cl-), metabolites (glucose, lactate), and oximetry parameters (total hemoglobin, oxygen saturation, hemoglobin fractions) using potentiometry, amperometry, and spectrophotometry. Modification adds rechargeable battery pack and charging status indicators (LEDs/screen symbols). Operated by trained technologists, nurses, physicians, or therapists. Output displayed on touch screen to assist clinical decision-making for life-threatening conditions and metabolic disorders.
Clinical Evidence
No clinical data provided. Performance characteristics are unchanged from the predicate device (K092686); bench testing only.
Technological Characteristics
Portable, automated analyzer. Measurement principles: potentiometry (pH, blood gases, electrolytes), amperometry (glucose, lactate), and spectrophotometry (hemoglobin). Power: 24 Vdc, 48W input; 24Vdc, 2250mAh output. Interface: menu-driven touch screen with LED status indicators. Software: Microsoft XPE operating system.
Indications for Use
Indicated for patients requiring blood gas, electrolyte, metabolite, and oximetry analysis in heparinized whole blood. Used by clinicians for diagnosis/treatment of acid-base disturbances, electrolyte imbalances, metabolic disorders (e.g., diabetes, cystic fibrosis), anemia, and carbon monoxide poisoning. Prescription use only.
Regulatory Classification
Identification
A blood gases (PCO2 , PO2 ) and blood pH test system is a device intended to measure certain gases in blood, serum, plasma or pH of blood, serum, and plasma. Measurements of blood gases (PCO2 , PO2 ) and blood pH are used in the diagnosis and treatment of life-threatening acid-base disturbances.
Predicate Devices
- ABL90 Flex (K092686)