Cardiac Allograft Gene Expression Profiling Test System

Page Type
Product Code
Definition
In vitro diagnostic multivariate index assay (ivdmia) test service, performed in a single laboratory, for assessing the gene expression profile of rna isolated from peripheral blood mononuclear cells (pbmc) and indicated for use to aid in the identification of heart transplant recipients with stable allograft function who have a low probability of moderate/severe acute cellular rejection (acr) at the time of testing in conjunction with standard clinical assessment.
Physical State
laboratory based test
Technical Method
quantitative real-time polymerase chain reaction technology (qRT-PCR)
Target Area
cardiac allograft
Regulation Medical Specialty
Cardiovascular
Review Panel
Chemistry
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
862.1163
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 862.1163 Cardiac allograft gene expression profiling test system

§ 862.1163 Cardiac allograft gene expression profiling test system.

(a) Identification. A cardiac allograft gene expression profiling test system is a device that measures the ribonucleic acid (RNA) expression level of multiple genes and combines this information to yield a signature (pattern, classifier, index, score) to aid in the identification of a low probability of acute cellular rejection (ACR) in heart transplant recipients with stable allograft function.

(b) Classification. Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: Cardiac Allograft Gene Expression Profiling Test Systems.” See § 862.1(d) for the availability of this guidance document.

[74 FR 53885, Oct. 21, 2009]

Cardiac Allograft Gene Expression Profiling Test System

Page Type
Product Code
Definition
In vitro diagnostic multivariate index assay (ivdmia) test service, performed in a single laboratory, for assessing the gene expression profile of rna isolated from peripheral blood mononuclear cells (pbmc) and indicated for use to aid in the identification of heart transplant recipients with stable allograft function who have a low probability of moderate/severe acute cellular rejection (acr) at the time of testing in conjunction with standard clinical assessment.
Physical State
laboratory based test
Technical Method
quantitative real-time polymerase chain reaction technology (qRT-PCR)
Target Area
cardiac allograft
Regulation Medical Specialty
Cardiovascular
Review Panel
Chemistry
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
862.1163
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 862.1163 Cardiac allograft gene expression profiling test system

§ 862.1163 Cardiac allograft gene expression profiling test system.

(a) Identification. A cardiac allograft gene expression profiling test system is a device that measures the ribonucleic acid (RNA) expression level of multiple genes and combines this information to yield a signature (pattern, classifier, index, score) to aid in the identification of a low probability of acute cellular rejection (ACR) in heart transplant recipients with stable allograft function.

(b) Classification. Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: Cardiac Allograft Gene Expression Profiling Test Systems.” See § 862.1(d) for the availability of this guidance document.

[74 FR 53885, Oct. 21, 2009]