MKJ · Automated External Defibrillators (Non-Wearable)

Cardiovascular · 21 CFR 870.5310 · Class 3

Overview

Product CodeMKJ
Device NameAutomated External Defibrillators (Non-Wearable)
Regulation21 CFR 870.5310
Device ClassClass 3
Review PanelCardiovascular

Identification

An automated external defibrillator (AED) system consists of an AED and those accessories necessary for the AED to detect and interpret an electrocardiogram and deliver an electrical shock (e.g., battery, pad electrode, adapter, and hardware key for pediatric use). An AED system analyzes the patient's electrocardiogram, interprets the cardiac rhythm, and automatically delivers an electrical shock (fully automated AED), or advises the user to deliver the shock (semi-automated or shock advisory AED) to treat ventricular fibrillation or pulseless ventricular tachycardia.

Classification Rationale

Class III (premarket approval)

Recent Cleared Devices (20 of 245)

Showing 20 most recent of 245 cleared devices.

RecordDevice NameApplicantDecision DateDecision
P200005TZ Medical Defibrillation Electrodes, Accessory Cables, and ConnectorsTz Medical, Inc.Jan 9, 2024APPR
P200007HeartSync Multifunction Disposable Single-Use AED Defibrillator PadsGraphic Controls D.B.A. VermedJun 23, 2023APPR
P210015Avive Automated External Defibrillator (AED) SystemAvive Solutions, Inc.Oct 31, 2022APPR
P200004ConMed PadPro Multifunction Electrodes, ConMed PadPro Multifunction Electrode AdaptersConmed CorporationSep 26, 2021APPR
P190013AED Battery Exchange (Models 9146-ABE, G5-ABE, 5070-ABE, FR3-ABE)Aed Battery Exchange, LLCFeb 2, 2021APPR
P190007Cardinal Health Multifunctional Defibrillation ElectrodeCardinalhealthAug 7, 2020APPR
P180028HeartStart FRx DefibrillatorPhilips Medical SystemsMay 11, 2020APPR
P160028Philips HeartStart FR3 DefibrillatorPhilips Medical Systems, Inc.May 11, 2020APPR
P170018LIFEPAK® CR2 DefibrillatorPhysio-Control, Inc.Dec 21, 2018APPR
P160033Powerheart® G5 AED, Powerheart® AED G3 Plus, and Powerheart® AED G3ZOLL Medical CorporationDec 7, 2018APPR
P160034Powerheart® AED G3 ProZOLL Medical CorporationDec 6, 2018APPR
P160026LIFEPAK 1000 DEFIBRILLATOR, LIFEPAK 20 DEFIBRILLATOR/ MONITOR, LIFEPAK 20E DEFIBRILLATOR/ MONITOR, LIFEPAK 15 MONITOR/DEPhysio-Control, Inc.Jul 2, 2018APPR
P160032Lifeline/ReviveR DDU-100, Lifeline/ReviveR AUTO DDU-120, Lifeline/ReviveR VIEW DDU-2300, Lifeline/ReviveR VIEW AUTO DDU-Defibtech, LLCFeb 1, 2018APPR
P160022X Series®, R Series®, AED Pro®, AED 3™ BLS Professional Defibrillators, Pro-Padz Radiotransparent Electrode, SurePower™ZOLL Medical CorporationDec 27, 2017APPR
P160012LIFEPAK CR® Plus Defibrillator, LIFEPAK EXPRESS® Defibrillator, and CHARGE-PAK® Battery ChargerPhysio-Control, Inc.Dec 21, 2017APPR
P160015AED Plus and Fully Automatic AED PlusZOLL Medical CorporationMay 26, 2017APPR
P160008HeartSine Technologies LLC's samaritan Public Access Automated External Defibrillators (SAM 350P, SAM 360P and SAM 450P)Heartsine Technologies, Ltd.Jan 12, 2017APPR
K143714Powerheart G5 AEDCardiac Science CorporationMay 4, 2015SESE
K150198CPR Dura-Padz Reusable Defibrillation Electrode with Dura-padz GelBio-Detek, Inc.May 2, 2015SESE
K150055OneStep Pediatric CPR Multi-Function ElectrodeBio-Detek, Inc.May 2, 2015SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...