NARKOMED GS ANESTHESIA SYSTEM
Device Facts
| Record ID | K963994 |
|---|---|
| Device Name | NARKOMED GS ANESTHESIA SYSTEM |
| Applicant | Draeger Medical, Inc. |
| Product Code | BSZ · Anesthesiology |
| Decision Date | Mar 19, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 868.5160 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The NMGS may be used for spontaneous, manually assisted, or automatic ventilation, and delivery of gases and anesthetic vapor. The NMGS can monitor oxygen concentration, breathing pressure, and respiratory volume.
Device Story
Narkomed GS (NMGS) is a continuous flow gas anesthesia system; provides spontaneous, manually assisted, or automatic ventilation; delivers anesthetic gases and vapors. Integrated monitors track oxygen concentration, breathing pressure, and respiratory volume. Used in clinical settings (OR) by anesthesia providers. Incorporates AV2+ anesthesia ventilator as integral subassembly. Features optional two or three vaporizer configurations. Includes serial interface (Vitalink protocol) for communication with external monitors (Vitalert 2000/3000). Supports clinical decision-making by providing real-time respiratory and gas delivery data to the clinician.
Clinical Evidence
Bench testing only. Qualification included hazard analysis, software verification, environmental testing, and electromagnetic compatibility testing.
Technological Characteristics
Continuous flow gas anesthesia system. Integrated monitors for O2, pressure, and volume. Serial interface (Vitalink protocol). Optional two or three vaporizer configurations. Software-controlled ventilation via AV2+ subassembly.
Indications for Use
Indicated for patients requiring spontaneous, manually assisted, or automatic ventilation and delivery of anesthetic gases/vapors during anesthesia procedures.
Regulatory Classification
Identification
A gas machine for anesthesia is a device used to administer to a patient, continuously or intermittently, a general inhalation anesthetic and to maintain a patient's ventilation. The device may include a gas flowmeter, vaporizer, ventilator, breathing circuit with bag, and emergency air supply. A gas machine for analgesia is a device used to administer to a patient an analgesic agent, such as a nitrous oxide-oxygen mixture (maximum concentration of 70 percent nitrous oxide).
Predicate Devices
Reference Devices
- Vitalert 2000 monitor
- Vitalert 3000 monitor
Related Devices
- K980553 — NARKOMED 6000 MODEL NUMBER NM6000 · Draeger Medical, Inc. · Aug 4, 1998
- K151954 — A7 Anesthesia System · Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · Oct 27, 2015
- K971425 — NARKOMED M ANESTHESIA SYSTEM (M) · Draeger Medical, Inc. · Sep 10, 1997
- K081844 — GE DATEX-OHMEDA AVANCE · Datex-Ohmeda, Inc. · Aug 29, 2008
- K042154 — GE DATEX-OHMEDA AISYS CARESTATION · Datex-Ohmeda, Inc. · Aug 31, 2004