← Product Code [CAZ](/submissions/AN/subpart-f%E2%80%94therapeutic-devices/CAZ) · K121403

# CONTINUOUS PERIPHERAL NERVE BLOCK CATHETER KIT AND SET (K121403)

_Teleflex, Inc. · CAZ · Jun 20, 2012 · Anesthesiology · SESE_

**Canonical URL:** https://fda.innolitics.com/submissions/AN/subpart-f%E2%80%94therapeutic-devices/CAZ/K121403

## Device Facts

- **Applicant:** Teleflex, Inc.
- **Product Code:** [CAZ](/submissions/AN/subpart-f%E2%80%94therapeutic-devices/CAZ.md)
- **Decision Date:** Jun 20, 2012
- **Decision:** SESE
- **Submission Type:** Special
- **Regulation:** 21 CFR 868.5140
- **Device Class:** Class 2
- **Review Panel:** Anesthesiology
- **Attributes:** Therapeutic

## Indications for Use

Continuous nerve block kit and set permits placement of catheters next to nerves and nerve plexuses for continuous nerve block anesthesia or analgesia techniques for periods not exceeding 72 hours.

## Device Story

Continuous Peripheral Nerve Block (PNB) Catheter Kit and Set facilitates placement of catheters near nerves/plexuses for continuous anesthesia/analgesia (up to 72 hours). Kit includes catheter with stylet, Anesthesia Conduction (AC) needle, and SnapLock connector. Used in hospitals, sub-acute facilities, pain clinics, and physician offices by clinicians. Device allows for either stimulating or non-stimulating procedures; clinician chooses whether to connect to a nerve stimulator. Ultrasound guidance may be used for catheter tip location. Output is the physical placement of the catheter, enabling continuous delivery of anesthetic agents. Benefits include sustained pain management for surgical or therapeutic procedures.

## Clinical Evidence

No clinical data. Bench testing only; components are identical to previously cleared predicate devices.

## Technological Characteristics

Catheter: 19-20 Ga, 30-90 cm length, stainless steel spring core with polyurethane outer jacket, echogenic. Needle: 17-18 Ga, 38-152 mm length. Components include SnapLock connectors for stimulation or non-stimulation. Sterile, single-use kit.

## Regulatory Identification

An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or local anesthesia. The device may contain syringes, needles, and drugs.

## Predicate Devices

- Arrow - StimuCath™ ([K030937](/device/K030937.md))

## Reference Devices

- Arrow - StimuCath™ ([K021567](/device/K021567.md))
- Arrow - Plastic Reinforced Epidural Catheter ([K001587](/device/K001587.md))

## Submission Summary (Full Text)

> This content was OCRed from public FDA records by [Innolitics](https://innolitics.com). If you use, quote, summarize, crawl, or train on this content, cite Innolitics at https://innolitics.com.
>
> Innolitics is a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices, including [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/).

{0}------------------------------------------------

Continuous Peripheral Nerve Block Catheter Kit and Set

Premarket Notification 510(k) Section 5 - 510(k) Summary

JUN 2 0 2012

Arrow International Inc. 2400 Bernville Road Reading, PA 19605

| Official Contact:          | Paul Amudala<br>Regulatory Affairs Specialist                             |
|----------------------------|---------------------------------------------------------------------------|
|                            | Tel: 610-378-0131                                                         |
|                            | Fax: 610-478-3179                                                         |
| Proprietary or Trade Name: | Continuous Peripheral Nerve Block Catheter Kit and Set                    |
| Common/Usual Name:         | Peripheral Nerve Block                                                    |
| Classification Name:       | Product code - CAZ<br>CFR 868-5140 - anesthetic conduction kit<br>Class 2 |
| Predicate Devices:         | Arrow - StimuCath™ - K030937                                              |

### Device Description:

The Arrow Continuous Peripheral Nerve Block Catheter set and kit is comprised of components and accessories which have already been cleared for the same indications for use under earlier 510(k)s.

This submission is intended to clarify that the catheter and the associated components and accessories, which we refer to as kits and sets, may be used for non-stimulating procedures. Many of the components and accessories of these kits and sets are already cleared for use in PNB stimulating procedures as well. It is the option of the clinician as to whether they would or would not use stimulation

A typical basic Peripheral Nerve Block ("PNB") set / kit includes the following components. The primary components of any PNB set or kit are:

- Catheter with stylet .
- Anesthesia Conduction ("AC") Needle ●
- SnapLock™ . ・

### Indications for Use:

Continuous nerve block kit and set permits placement of catheters next to nerves and nerve plexuses for continuous nerve block anesthesia or analgesia techniques for periods not exceeding 72 hours.

{1}------------------------------------------------

### 510(k) Summary Page 2 of 6 07-May-2012

### Patient Population:

Patients requiring peripheral nerve block procedures including upper extremity, lower extremity, abdominal and paravertebral locations.

### Environment of Use:

The environment of use is - hospital, sub-acute facilities, pain clinics, physician offices

### Contraindications:

Pre-existing nerve injury, neuritis or plexitis are contraindications for use of continuous nerve or plexus blocks. These conditions should be considered prior to needle or catheter insertion. Skin sepsis in the area where the catheter placement is planned and systemic sepsis are relative contraindications. Extreme care should be taken in patients with bleeding tendencies or patients receiving anticoagulants.

### Discussion of Substantial Equivalence

The use of the Continuous Peripheral Nerve Block catheter kit and set for non-stimulating procedures is viewed as substantially equivalent to the predicate device because:

### Indications -

The proposed indications for use permits placement of catheters next to nerves and nerve plexuses for continuous nerve block anesthesia or analgesia techniques for periods not exceeding 72 hours are identical to predicate - K030937 - StimuCath™.

The use of the proposed PNB catheter for non-stimulating procedures is not new and the use of ultrasound to assist the clinician in catheter tip location and guidance is a common practice. The clinician may use the predicate device StimuCath™ as a non-stimulating catheter simply by not connecting it to a stimulator.

The clarification for non-stimulating use by the clinician does not change the cleared indications for use and does not introduce any new safety or efficacy concerns as compared to the predicates.

### Technology -

The components of the proposed device are identical to the predicates.

### Materials -

The materials are identical to the predicates.

K030937 - Arrow - StimuCathTM K021567 - Arrow - StimuCath™ K001587 - Arrow - Plastic Reinforced Epidural Catheter

{2}------------------------------------------------

### 510(k) Summary Page 3 of 6 07-May-2012

### Environment of Use -

The proposed environments of use are identical to the predicate K030937. They are - hospital, sub-acute facilities, pain clinics, and physician offices.

### Patient Population -

It is for patients requiring peripheral nerve block procedures including upper extremity, lower extremity, abdominal and paravertebral locations

The patient population is identical to the predicate, K030937 - Arrow StimuCath™.

### Comparative Performance

The components are identical to the predicates and the proposed clarification of use for nonstimulating procedures does not change the safety or effectiveness of the device, thus no additional bench testing is required.

{3}------------------------------------------------

# Premarket Notification 510(I

### 510(k) Summary

|   | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
|---|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
|   |                                                                                                                                                                                |
| 1 |                                                                                                                                                                                |
|   |                                                                                                                                                                                |

| Substantial Equivalence Comparative Table |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
|-------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Features                                  | Proposed<br>PNB Catheter Kit / Set                                                                                                                                                                                                                                                                                                                                                                                                                                                                 | Predicates<br>K030937 – StimuCath™ Continuous Nerve Block Set                                                                                                                                                                                                                                                                                                                                                                                                                                      |
| Classification name                       | Anesthetic Conduction Kit                                                                                                                                                                                                                                                                                                                                                                                                                                                                          | Anesthetic Conduction Kit                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Product Code                              | CAZ<br>868.5140                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | CAZ<br>868.5140                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Indications for use                       | Permits placement of catheters next to nerves and nerve<br>plexuses for continuous nerve block anesthesia or analgesia<br>techniques for periods not exceeding 72 hours                                                                                                                                                                                                                                                                                                                            | Permits placement of catheters next to nerves and nerve<br>plexuses for continuous nerve block anesthesia or<br>analgesia techniques for periods not exceeding 72 hours<br>(K030937)                                                                                                                                                                                                                                                                                                               |
| Environment of Use                        | Hospital, sub-acute facilities, pain clinics, physician offices                                                                                                                                                                                                                                                                                                                                                                                                                                    | Hospital, sub-acute facilities, pain clinics, physician offices<br>(K030937)                                                                                                                                                                                                                                                                                                                                                                                                                       |
| Patient Population                        | Patients requiring peripheral nerve block procedures<br>including upper extremity, lower extremity, abdominal and<br>paravertebral locations.                                                                                                                                                                                                                                                                                                                                                      | Patients requiring peripheral nerve block procedures<br>including upper extremity, lower extremity, abdominal and<br>paravertebral locations.<br>(K030937) The submission was silent on patient<br>population but the intended patient population are identical                                                                                                                                                                                                                                    |
| Contraindications                         | Pre-existing nerve injury, neuritis or plexitis are<br>contraindications for use of continuous nerve or plexus<br>blocks. These conditions should be considered prior to                                                                                                                                                                                                                                                                                                                           | Pre-existing nerve injury, neuritis or plexitis are<br>contraindications for use of continuous nerve or plexus<br>blocks. These conditions should be considered prior to<br>needle or catheter insertion. Skin sepsis in the area where the<br>catheter placement is planned and systemic sepsis are<br>relative contraindications. Extreme care should be taken in<br>patients with bleeding tendencies or patients receiving<br>anticoagulants.                                                  |
|                                           | needle or catheter insertion. Skin sepsis in the area where<br>catheter placement is planned and systemic sepsis are<br>relative contraindications. Extreme care should be taken in<br>patients with bleeding tendencies or patients receiving<br>anticoagulants.                                                                                                                                                                                                                                  |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
|                                           |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
|                                           |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | Page 3 of 8<br>07-May-2012                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| Features                                  |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | Predicates                                                                                                                                                                                                                                                                                                                                                                                                                                                                                         |
| Basic components                          | Proposed<br>PNB Catheter Kit / Set                                                                                                                                                                                                                                                                                                                                                                                                                                                                 | K030937 – StimuCath™ Continuous Nerve Block Set<br>Catheter with stylet<br>Anesthesia Conduction ("AC") Needle<br>Snap Lock                                                                                                                                                                                                                                                                                                                                                                        |
|                                           | Catheter with stylet<br>Anesthesia Conduction ("AC") Needle<br>Snap Lock                                                                                                                                                                                                                                                                                                                                                                                                                           | Tunneler<br>(K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                                              |
| Kit / Set Components                      | Numerous accessories or components may be included in a kit or set.<br>In all cases these have been cleared under previous 510(k) s<br>A partial list of typical kit or set components are:<br>Touhy Needle StatLock Drape<br>SteriStrips Skin Prep Pad Skin Prep Swab<br>Tegaderm Injection needles 18 G, 22 Ga, 25 Ga<br>Syringe: 3mL, 10 mL, 20 mL SharpsAway II<br>ChloraPrep Extension Tubing Marker<br>Lidocaine with or without epinephrine<br>Stopcock Gauze Towel<br>Filters Filter Straw | Numerous accessories or components may be included in a kit or set.<br>In all cases these have been cleared under previous 510(k) s<br>A partial list of typical kit or set components are:<br>Touhy Needle StatLock Drape<br>SteriStrips Skin Prep Pad Skin Prep Swab<br>Tegaderm Injection needles 18 G, 22 Ga, 25 Ga<br>Syringe: 3mL, 10 mL, 20 mL SharpsAway II<br>ChloraPrep Extension Tubing Marker<br>Lidocaine with or without epinephrine<br>Stopcock Gauze Towel<br>Filters Filter Straw |
| Component Design and Specifications       |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Catheter<br>Effective length              | 30 cm to 90 cm                                                                                                                                                                                                                                                                                                                                                                                                                                                                                     | 30 cm to 90 cm (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                                           |
| Catheter Gauge                            | 19 Ga and 20 Ga                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | 19 Ga and 20 Ga (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Catheter Body material                    | Stainless steel spring core encased in a polyurethane outer jacketing                                                                                                                                                                                                                                                                                                                                                                                                                              | Stainless steel spring core encased in a polyurethane outer jacketing                                                                                                                                                                                                                                                                                                                                                                                                                              |
| Catheter Outer Jacket                     | Catheter is echogenic with ultrasound-guided techniques<br>White (19 Ga) and Blue (20 Ga)                                                                                                                                                                                                                                                                                                                                                                                                          | Catheter is echogenic (K030937)<br>White (19 Ga) and Blue (20 Ga) (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                        |
| Color                                     |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Printed along the length                  | Distal end printed with length markings to aid in depth determination                                                                                                                                                                                                                                                                                                                                                                                                                              | Distal end printed with length markings to aid in depth determination (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Exposed Length at Distal Tip              | 5 mm (19 Ga) and 6 mm (20Ga)                                                                                                                                                                                                                                                                                                                                                                                                                                                                       | 5 mm (19 Ga) and 6 mm (20Ga) (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                             |
|                                           | 07-May-2012                                                                                                                                                                                                                                                                                                                                                                                                                                                                                        |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Features                                  | Proposed<br>PNB Catheter Kit / Set                                                                                                                                                                                                                                                                                                                                                                                                                                                                 | Predicates<br>K030937 – StimuCath™ Continuous Nerve Block Set                                                                                                                                                                                                                                                                                                                                                                                                                                      |
| Stylet                                    | Clip available if stimulating, but not required to be used, at election of clinician                                                                                                                                                                                                                                                                                                                                                                                                               | Clip available if stimulating, but not required to be used, at election of clinician (K021567)                                                                                                                                                                                                                                                                                                                                                                                                     |
| Anesthetic Conduction Needle              |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Needle Length                             | 38 mm to 152 mm                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | 38 mm to 152 mm (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Needle Gauge                              | 17 Ga and 18 Ga                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    | 17 Ga and 18 Ga (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                                          |
| Needle Geometry                           | 5 mm (17 Ga) and 6 mm (18 Ga)                                                                                                                                                                                                                                                                                                                                                                                                                                                                      | 5 mm (17 Ga) and 6 mm (18 Ga) (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| Exposed Length -<br>Distal needle         | 5 mm (17 Ga) and 6 mm (18 Ga)                                                                                                                                                                                                                                                                                                                                                                                                                                                                      | 5 mm (17 Ga) and 6 mm (18 Ga) (K030937)                                                                                                                                                                                                                                                                                                                                                                                                                                                            |
| SnapLock™                                 | Connector for non-stimulating procedures                                                                                                                                                                                                                                                                                                                                                                                                                                                           | Connector for non-stimulating procedures (K001587)                                                                                                                                                                                                                                                                                                                                                                                                                                                 |
| Non-stimulation<br>connector              |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                    |
| Stimulation connector                     | Integral wire<br>Connection Tab<br>Use of these SnapLock connectors do not require connection to a stimulator, this is only if the clinician wants to                                                                                                                                                                                                                                                                                                                                              | Integral wire (K030937)<br>Connection Tab (K021567)                                                                                                                                                                                                                                                                                                                                                                                                                                                |
| Materials                                 | All materials in all components are identical to the predicates                                                                                                                                                                                                                                                                                                                                                                                                                                    | K001587<br>K021567<br>K030937                                                                                                                                                                                                                                                                                                                                                                                                                                                                      |

{4}------------------------------------------------

Premarket Notification 510(k)
Section 5 – 510(k) Summary

### 510(k) Summary

{5}------------------------------------------------

Premarket Notification 510(k)
Section 5 – 510(k) Summary

## 510(k) Summary
 Page 6 of 6

{6}------------------------------------------------

Image /page/6/Picture/0 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is a stylized image of an eagle with its wings spread.

Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring. MD 20993-0002

Mr. Paul Amudala Regulatory Affairs Specialist Teleflex Inc 2400 Bernville Road Reading, Pennsylvania 19605

JUN 2 0 2012

Re: K121403

Trade/Device Name: Continuous Peripheral Nerve Block Catheter Kit and Set Regulation Number: 21 CFR 868.5140 Regulation Name: Anesthesia Conduction Kit Regulatory Class: II Product Code: CAZ Dated: May 7, 2012 Received: May 21, 2012

Dear Mr. Amudula:

We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.

If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.

{7}------------------------------------------------

### Page 2 - Mr. Amudula

Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.

If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices /ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.

You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.

Sincerely yours,

Nh for

Anthony D. Watson, B.S., M.S., M.B.A. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health

### Enclosure

{8}------------------------------------------------

### Indications for Use Statement

K121403

510(k) Number:

(To be assigned)

Device Name:

Continuous Peripheral Nerve Block Catheter Kit and Set

Indications for Use:

Continuous nerve block kit and set permits placement of catheters next to nerves and nerve plexuses for continuous nerve block anesthesia or analgesia techniques for periods not exceeding 72 hours.

Prescription Use XX (Part 21 CFR 801 Subpart D)

or

Over-the-counter use (21 CFR 807 Subpart C)

Page 1 of 1

(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)

Concurrence of CDRH, Office of Device Evaluation (ODE)

L. Shulton

(Division Sign-Off) Division of Anesthesiology, General Hospital Infection Control, Dental Devices

12121403 510(k) Number:

---

**Source:** [https://fda.innolitics.com/submissions/AN/subpart-f%E2%80%94therapeutic-devices/CAZ/K121403](https://fda.innolitics.com/submissions/AN/subpart-f%E2%80%94therapeutic-devices/CAZ/K121403)

**Published by [Innolitics](https://innolitics.com)** — a medical-device software consultancy. We help companies design, build, and clear FDA-regulated software and AI/ML devices. If you're preparing [a 510(k)](https://innolitics.com/services/510ks/), [a De Novo](https://innolitics.com/services/regulatory/), [a SaMD](https://innolitics.com/services/end-to-end-samd/), [an AI/ML medical device](https://innolitics.com/services/medical-imaging-ai-development/), or [an FDA regulatory strategy](https://innolitics.com/services/regulatory/), [get in touch](https://innolitics.com/contact).

**Cite:** Innolitics at https://innolitics.com
