BRW
Protector, Dental
1
Product Code
BSF
Absorber, Carbon-Dioxide
1
Product Code
BSJ
Mask, Gas, Anesthetic
1
Product Code
BSK
Cuff, Tracheal Tube, Inflatable
2
Product Code
BSN
Filter, Conduction, Anesthetic
2
Product Code
BSO
Catheter, Conduction, Anesthetic
2
Product Code
BSP
Needle, Conduction, Anesthetic (W/Wo Introducer)
2
Product Code
BSR
Stylet, Tracheal Tube
1
Product Code
BSZ
Gas-Machine, Anesthesia
2
Product Code
BTB
Hook, Ether
1
Product Code
BTC
Bag, Reservoir
1
Product Code
BTK
Strap, Head, Gas Mask
1
Product Code
BTL
Ventilator, Emergency, Powered (Resuscitator)
2
Product Code
BTM
Ventilator, Emergency, Manual (Resuscitator)
2
Product Code
BTO
Tube, Tracheostomy (W/Wo Connector)
2
Product Code
BTP
Dropper, Ether
1
Product Code
BTQ
Airway, Nasopharyngeal
1
Product Code
BTR
Tube, Tracheal (W/Wo Connector)
2
Product Code
BTS
Tube, Bronchial (W/Wo Connector)
2
Product Code
BTT
Humidifier, Respiratory Gas, (Direct Patient Interface)
2
Product Code
BWB
Forceps, Tube Introduction
1
Product Code
BWC
Needle, Emergency Airway
2
Product Code
BWF
Spirometer, Therapeutic (Incentive)
2
Product Code
BWL
Apparatus, Electronanesthesia
3
Product Code
BYD
Condenser, Heat And Moisture (Artificial Nose)
1
Product Code
BYE
Attachment, Breathing, Positive End Expiratory Pressure
2
Product Code
BYF
Mask, Oxygen, Low Concentration, Venturi
1
Product Code
BYG
Mask, Oxygen
1
Product Code
BYH
Drain, Tee (Water Trap)
1
Product Code
BYI
Percussor, Powered-Electric
2
Product Code
BYJ
Unit, Liquid-Oxygen, Portable
2
Product Code
BYK
Tent, Oxygen, Electrically Powered
2
Product Code
BYL
Tent, Oxygen
1
Product Code
BYN
Chair, Posture, For Cardiac And Pulmonary Treatment
1
Product Code
BYO
Bottle, Blow
1
Product Code
BYP
Mouthpiece, Breathing
1
Product Code
BYT
Ventilator, External Body, Negative Pressure, Adult (Cuirass)
2
Product Code
BYW
Device, Rebreathing
1
Product Code
BYX
Tubing, Pressure And Accessories
1
Product Code
BZA
Connector, Airway (Extension)
1
Product Code
BZB
Catheter, Nasal, Oxygen
1
Product Code
BZD
Ventilator, Non-Continuous (Respirator)
2
Product Code
BZE
Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
2
Product Code
BZO
Set, Tubing And Support, Ventilator (W Harness)
1
Product Code
BZR
Mixer, Breathing Gases, Anesthesia Inhalation
2
Product Code
CAD
Vaporizer, Anesthesia, Non-Heated
2
Product Code
K
24
0375
V80 Anesthetic Vaporizer (V80)
2
Cleared 510(K)
K
17
2702
Tec 820, Tec 850
2
Cleared 510(K)
K
15
0167
V60 Anesthetic Vaporizer
2
Cleared 510(K)
K
11
0608
SEVOFLURANE VAPORIZER ADAPTOR
2
Cleared 510(K)
K
06
0331
SIGMA ALPHA VAPORIZER
2
Cleared 510(K)
K
05
3564
KEYED FILLER BOTTLE ADAPTOR, MODELS 53450, 53452, 53453, 53454
2
Cleared 510(K)
K
05
1666
GAV - GENERAL ANAESTHETIC VAPORIZER
2
Cleared 510(K)
K
04
2276
D-VAPOR
2
Cleared 510(K)
K
04
1076
DELTA T
2
Cleared 510(K)
K
03
1027
DATEX-OHMEDA TEC 7 ANESTHESIA VAPORIZER (ENFLURANE)
2
Cleared 510(K)
K
01
2924
DATEX-OHMEDA TEC 7 ANESTHESIA VAPORIZER
2
Cleared 510(K)
K
00
2343
SIGMA DELTA
2
Cleared 510(K)
K
00
2878
DATEX-OHMEDA D-TEC PLUS ANESTHESIA VAPORIZER
2
Cleared 510(K)
K
00
0275
DATEX-OHMEDA TEC 6 PLUS ANESTHESIA VAPORIZER, DATEX-OHMEDA TEC 6 PLUS NAD VARIANT ANESTHESIA
2
Cleared 510(K)
K
99
0132
DATEX-OHMEDA ANESTHESIA VAPORIZER, MODEL D-TEC
2
Cleared 510(K)
K
98
0489
VAPAMASTA 6
2
Cleared 510(K)
K
98
0884
SIEMENS SEVOFLURANE VAPORIZER SV 953
2
Cleared 510(K)
K
98
1773
DRAGER-VAPOR 19.3
2
Cleared 510(K)
K
98
1472
DRAGER-VAPOR 19.1 W/PLUG SYSTEM S PLUS
2
Cleared 510(K)
K
97
3051
DRAGER-VAPOR 19.1 W/PLUG SYSTEM S PLUS
2
Cleared 510(K)
K
97
1923
DRAGER-VAPOR 2000
2
Cleared 510(K)
K
95
2083
TEC IV AND TEC V ANESTHESIA VAPORIZERS FOR SEVOFLURANE
2
Cleared 510(K)
K
96
1468
QUIK-FIL VAPORIZER KEYED FILLER
2
Cleared 510(K)
K
96
0944
PPV VAPORIZER (MODIFICATION)
2
Cleared 510(K)
K
95
4801
TECHFIL
2
Cleared 510(K)
K
95
3748
TECHNOFIL
2
Cleared 510(K)
K
94
2799
DATUM
2
Cleared 510(K)
K
94
2091
OHMEDA TEC 5 VAPORIZER FOR USE WITH SEVOFLURANE
2
Cleared 510(K)
K
94
5993
VAPOFIL
2
Cleared 510(K)
K
94
2545
SIGMA ELITE
2
Cleared 510(K)
K
94
2055
DRAGER-VAPOR 19.1
2
Cleared 510(K)
K
93
6046
SIGMA ELITE
2
Cleared 510(K)
K
92
3265
FUNNEL ADAPTOR
2
Cleared 510(K)
K
91
3593
OHMEDA TEC 6 CONTINUOUS FLOW VAPORIZER
2
Cleared 510(K)
K
89
2057
OHMEDA TEC 5 CONTINUOUS FLOW VAPORIZER
2
Cleared 510(K)
K
88
4686
VAPAMASTA 5
2
Cleared 510(K)
K
88
4090
LUNDY VAPORIZER SYSTEM
2
Cleared 510(K)
K
88
2500
VAPORIZER, ANESTHESIA, NON-HEATED
2
Cleared 510(K)
K
87
2053
KEYFILL
2
Cleared 510(K)
K
86
4605
VAPLOK
2
Cleared 510(K)
K
86
1839
VAPOFIL
2
Cleared 510(K)
K
86
0545
VAPORIZER SPACER
2
Cleared 510(K)
K
85
4202
ANESTHESIA VENTILATOR MODEL 100
2
Cleared 510(K)
K
84
4007
PENLON PPV VAPORIZER
2
Cleared 510(K)
K
84
3993
ANAESLOCK THREE VAPORIZER INTERLOCK HVA003
2
Cleared 510(K)
K
84
1157
HALOTHANE VAPORIZER 950, ENFLURANE
2
Cleared 510(K)
K
83
1427
CYPRANE TEC 4 CONTINUOUS FLOW VAPOR.
2
Cleared 510(K)
K
82
1966
MODULUS VERNI-TROL ANESTHETIC VAPORIZER
2
Cleared 510(K)
K
82
1650
DRAGER VAPOR 19.1 ANESTHETIC VAPORIZERS
2
Cleared 510(K)
K
81
0289
MODULUS VERNI-TROL ANESTHETIC VAPORIZER
2
Cleared 510(K)
K
79
0359
HALOTHANE VAPORIZER 950, & ENFLURANE 951
2
Cleared 510(K)
K
77
1892
VALVE ANESTHETIC
2
Cleared 510(K)
K
77
1899
VAPOR 19
2
Cleared 510(K)
K
77
1150
COPPER KETTLE VAPORIZER PLUS
2
Cleared 510(K)
K
77
0021
MASK, FACE, SURGICAL
2
Cleared 510(K)
K
76
1160
MODEL CNA-1 VAPORIZER
2
Cleared 510(K)
K
76
0668
SELECTATEC SYSTEM
2
Cleared 510(K)
CAE
Airway, Oropharyngeal, Anesthesiology
1
Product Code
CAF
Nebulizer (Direct Patient Interface)
2
Product Code
CAG
Circulator, Breathing-Circuit
2
Product Code
CAI
Circuit, Breathing (W Connector, Adaptor, Y Piece)
1
Product Code
CAL
Laryngoscope, Non-Rigid
1
Product Code
CAO
Airway, Esophageal (Obturator)
2
Product Code
CAT
Cannula, Nasal, Oxygen
1
Product Code
CAW
Generator, Oxygen, Portable
2
Product Code
CAZ
Anesthesia Conduction Kit
2
Product Code
CBF
Chamber, Hyperbaric
2
Product Code
CBG
Spreader, Cuff
1
Product Code
CBH
Device, Fixation, Tracheal Tube
1
Product Code
CBI
Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector)
2
Product Code
CBK
Ventilator, Continuous, Facility Use
2
Product Code
CBL
Absorbent, Carbon-Dioxide
1
Product Code
CBN
Apparatus, Gas-Scavenging
2
Product Code
CBO
Attachment, Intermittent Mandatory Ventilation (Imv)
2
Product Code
CBP
Valve, Non-Rebreathing
2
Product Code
MOD
Accessory To Continuous Ventilator (Respirator)
2
Product Code
CCO
Bed, Rocking, Breathing Assist
2
Product Code
CCQ
Nebulizer, Medicinal, Non-Ventilatory (Atomizer)
1
Product Code
CCT
Applicator (Laryngo-Tracheal), Topical Anesthesia
2
Product Code
CCW
Laryngoscope, Rigid
1
Product Code
EPE
Brush, Cleaning, Tracheal Tube
1
Product Code
FNC
Tent, Pediatric Aerosol
2
Product Code
FOG
Hood, Oxygen, Infant
1
Product Code
JAY
Support, Breathing Tube
1
Product Code
JOH
Tube Tracheostomy And Tube Cuff
2
Product Code
KFZ
Humidifier, Non-Direct Patient Interface (Home-Use)
1
Product Code
KGB
Mask, Oxygen, Non-Rebreathing
1
Product Code
KHA
Mask, Scavenging
1
Product Code
LNZ
Changer, Tube, Endotracheal
2
Product Code
MIA
Needle, Spinal, Short Term
2
Product Code
MNS
Ventilator, Continuous, Non-Life-Supporting
2
Product Code
MNT
Ventilator, Continuous, Minimal Ventilatory Support, Facility Use
2
Product Code
MRN
Apparatus, Nitric Oxide Delivery
2
Product Code
MRO
Apparatus, Nitric Oxide, Backup Delivery
2
Product Code
MZT
Device, Heimlich Maneuver Assist
2
Product Code
NFB
Conserver, Oxygen
2
Product Code
NHJ
Device, Positive Pressure Breathing, Intermittent
2
Product Code
NHK
Resuscitator, Manual, Non Self-Inflating
2
Product Code
NMA
Tube, Tracheal, Reprocessed
2
Product Code
NMC
Mask, Ventilator, Non-Continuous, Reprocessed
2
Product Code
NMR
Needle, Spinal, Short Term, Reprocessed
2
Product Code
NNH
Needle, Conduction, Anesthesia, Reprocessed
2
Product Code
NOU
Continuous, Ventilator, Home Use
2
Product Code
NQY
Ventilator, Continuous, Minimal Ventilatory Support, Home Use
2
Product Code
NVO
Spacer, Direct Patient Interface
2
Product Code
NVP
Holding Chambers, Direct Patient Interface
2
Product Code
NXA
Tracheotomy Care Kit
2
Product Code
OBN
Humidifier, Respiratory, Mask (Direct Patient Interface)
2
Product Code
OFQ
Anesthesia Kit
2
Product Code
OFT
Spinal Epidural Anesthesia Kit
2
Product Code
OFU
Spinal Anesthesia Kit
2
Product Code
OFV
Regional Anesthesia Kit
2
Product Code
OGA
Brachial Plexus Anesthesia Kit
2
Product Code
OGB
Caudal Anesthesia Kit
2
Product Code
OGC
Continuous Brachial Plexus Block Tray
2
Product Code
OGD
Custom Anesthesia Tray
2
Product Code
OGE
Epidural Anesthesia Kit
2
Product Code
OGF
Glossopharyngeal Anesthesia Kit
2
Product Code
OGG
Humidifier Nebulizer Kit
2
Product Code
OGH
Laryngoscope Kit
1
Product Code
OGI
Nasal Endotracheal Tube Holder Kit
1
Product Code
OGJ
Nerve Block Tray
2
Product Code
OGL
Oxygen Administration Kit
2
Product Code
OLF
Medevac Use Oxygen Generator
2
Product Code
ONZ
Mechanical Ventilator
2
Product Code
OQU
Airway Monitoring System
2
Product Code
PHS
Oral Airway Assist
1
Product Code
PMB
External Airway
2
Product Code
QAV
High Flow/High Velocity Humidified Oxygen Delivery Device
2
Product Code
QBY
Positive Airway Pressure System
2
Product Code
QCX
Retrograde Intubation Set
2
Product Code
OZR
Intraoral Pressure Gradient Device
2
Product Code
QFB
Isocapnic Ventilation Device
2
Product Code
SDS
Compression-Based Airway Clearance Device
2
Product Code
SDT
Intra-Pulmonary Percussive Vibration (Ipv) Devices
2
Product Code
SFP
Ventilator-Compatible Nebulizer
2
Product Code
Subpart G—Miscellaneous
CFR Sub-Part
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 12 October 2025 at 8:21 pm
AN
/
subpart-f—therapeutic-devices
/
CAD
/
K841157
View Source
HALOTHANE VAPORIZER 950, ENFLURANE
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K841157
510(k) Type
Traditional
Applicant
SIEMENS ELEMA AB
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/7/1984
Days to Decision
80 days
FDA Browser
by
Innolitics
Anesthesiology
Miscellaneous
Subpart B—Cardiovascular Diagnostic Devices
Subpart B—Diagnostic Devices
Subpart B—Neurological Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—Monitoring Devices
Subpart D—Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—Cardiovascular Therapeutic Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Subpart F—Therapeutic Devices
BRW
Protector, Dental
BSF
Absorber, Carbon-Dioxide
BSJ
Mask, Gas, Anesthetic
BSK
Cuff, Tracheal Tube, Inflatable
BSN
Filter, Conduction, Anesthetic
BSO
Catheter, Conduction, Anesthetic
BSP
Needle, Conduction, Anesthetic (W/Wo Introducer)
BSR
Stylet, Tracheal Tube
BSZ
Gas-Machine, Anesthesia
BTB
Hook, Ether
BTC
Bag, Reservoir
BTK
Strap, Head, Gas Mask
BTL
Ventilator, Emergency, Powered (Resuscitator)
BTM
Ventilator, Emergency, Manual (Resuscitator)
BTO
Tube, Tracheostomy (W/Wo Connector)
BTP
Dropper, Ether
BTQ
Airway, Nasopharyngeal
BTR
Tube, Tracheal (W/Wo Connector)
BTS
Tube, Bronchial (W/Wo Connector)
BTT
Humidifier, Respiratory Gas, (Direct Patient Interface)
BWB
Forceps, Tube Introduction
BWC
Needle, Emergency Airway
BWF
Spirometer, Therapeutic (Incentive)
BWL
Apparatus, Electronanesthesia
BYD
Condenser, Heat And Moisture (Artificial Nose)
BYE
Attachment, Breathing, Positive End Expiratory Pressure
BYF
Mask, Oxygen, Low Concentration, Venturi
BYG
Mask, Oxygen
BYH
Drain, Tee (Water Trap)
BYI
Percussor, Powered-Electric
BYJ
Unit, Liquid-Oxygen, Portable
BYK
Tent, Oxygen, Electrically Powered
BYL
Tent, Oxygen
BYN
Chair, Posture, For Cardiac And Pulmonary Treatment
BYO
Bottle, Blow
BYP
Mouthpiece, Breathing
BYT
Ventilator, External Body, Negative Pressure, Adult (Cuirass)
BYW
Device, Rebreathing
BYX
Tubing, Pressure And Accessories
BZA
Connector, Airway (Extension)
BZB
Catheter, Nasal, Oxygen
BZD
Ventilator, Non-Continuous (Respirator)
BZE
Heater, Breathing System W/Wo Controller (Not Humidifier Or Nebulizer
BZO
Set, Tubing And Support, Ventilator (W Harness)
BZR
Mixer, Breathing Gases, Anesthesia Inhalation
CAD
Vaporizer, Anesthesia, Non-Heated
K
24
0375
V80 Anesthetic Vaporizer (V80)
K
17
2702
Tec 820, Tec 850
K
15
0167
V60 Anesthetic Vaporizer
K
11
0608
SEVOFLURANE VAPORIZER ADAPTOR
K
06
0331
SIGMA ALPHA VAPORIZER
K
05
3564
KEYED FILLER BOTTLE ADAPTOR, MODELS 53450, 53452, 53453, 53454
K
05
1666
GAV - GENERAL ANAESTHETIC VAPORIZER
K
04
2276
D-VAPOR
K
04
1076
DELTA T
K
03
1027
DATEX-OHMEDA TEC 7 ANESTHESIA VAPORIZER (ENFLURANE)
K
01
2924
DATEX-OHMEDA TEC 7 ANESTHESIA VAPORIZER
K
00
2343
SIGMA DELTA
K
00
2878
DATEX-OHMEDA D-TEC PLUS ANESTHESIA VAPORIZER
K
00
0275
DATEX-OHMEDA TEC 6 PLUS ANESTHESIA VAPORIZER, DATEX-OHMEDA TEC 6 PLUS NAD VARIANT ANESTHESIA
K
99
0132
DATEX-OHMEDA ANESTHESIA VAPORIZER, MODEL D-TEC
K
98
0489
VAPAMASTA 6
K
98
0884
SIEMENS SEVOFLURANE VAPORIZER SV 953
K
98
1773
DRAGER-VAPOR 19.3
K
98
1472
DRAGER-VAPOR 19.1 W/PLUG SYSTEM S PLUS
K
97
3051
DRAGER-VAPOR 19.1 W/PLUG SYSTEM S PLUS
K
97
1923
DRAGER-VAPOR 2000
K
95
2083
TEC IV AND TEC V ANESTHESIA VAPORIZERS FOR SEVOFLURANE
K
96
1468
QUIK-FIL VAPORIZER KEYED FILLER
K
96
0944
PPV VAPORIZER (MODIFICATION)
K
95
4801
TECHFIL
K
95
3748
TECHNOFIL
K
94
2799
DATUM
K
94
2091
OHMEDA TEC 5 VAPORIZER FOR USE WITH SEVOFLURANE
K
94
5993
VAPOFIL
K
94
2545
SIGMA ELITE
K
94
2055
DRAGER-VAPOR 19.1
K
93
6046
SIGMA ELITE
K
92
3265
FUNNEL ADAPTOR
K
91
3593
OHMEDA TEC 6 CONTINUOUS FLOW VAPORIZER
K
89
2057
OHMEDA TEC 5 CONTINUOUS FLOW VAPORIZER
K
88
4686
VAPAMASTA 5
K
88
4090
LUNDY VAPORIZER SYSTEM
K
88
2500
VAPORIZER, ANESTHESIA, NON-HEATED
K
87
2053
KEYFILL
K
86
4605
VAPLOK
K
86
1839
VAPOFIL
K
86
0545
VAPORIZER SPACER
K
85
4202
ANESTHESIA VENTILATOR MODEL 100
K
84
4007
PENLON PPV VAPORIZER
K
84
3993
ANAESLOCK THREE VAPORIZER INTERLOCK HVA003
K
84
1157
HALOTHANE VAPORIZER 950, ENFLURANE
K
83
1427
CYPRANE TEC 4 CONTINUOUS FLOW VAPOR.
K
82
1966
MODULUS VERNI-TROL ANESTHETIC VAPORIZER
K
82
1650
DRAGER VAPOR 19.1 ANESTHETIC VAPORIZERS
K
81
0289
MODULUS VERNI-TROL ANESTHETIC VAPORIZER
K
79
0359
HALOTHANE VAPORIZER 950, & ENFLURANE 951
K
77
1892
VALVE ANESTHETIC
K
77
1899
VAPOR 19
K
77
1150
COPPER KETTLE VAPORIZER PLUS
K
77
0021
MASK, FACE, SURGICAL
K
76
1160
MODEL CNA-1 VAPORIZER
K
76
0668
SELECTATEC SYSTEM
CAE
Airway, Oropharyngeal, Anesthesiology
CAF
Nebulizer (Direct Patient Interface)
CAG
Circulator, Breathing-Circuit
CAI
Circuit, Breathing (W Connector, Adaptor, Y Piece)
CAL
Laryngoscope, Non-Rigid
CAO
Airway, Esophageal (Obturator)
CAT
Cannula, Nasal, Oxygen
CAW
Generator, Oxygen, Portable
CAZ
Anesthesia Conduction Kit
CBF
Chamber, Hyperbaric
CBG
Spreader, Cuff
CBH
Device, Fixation, Tracheal Tube
CBI
Tube, Tracheal/Bronchial, Differential Ventilation (W/Wo Connector)
CBK
Ventilator, Continuous, Facility Use
CBL
Absorbent, Carbon-Dioxide
CBN
Apparatus, Gas-Scavenging
CBO
Attachment, Intermittent Mandatory Ventilation (Imv)
CBP
Valve, Non-Rebreathing
MOD
Accessory To Continuous Ventilator (Respirator)
CCO
Bed, Rocking, Breathing Assist
CCQ
Nebulizer, Medicinal, Non-Ventilatory (Atomizer)
CCT
Applicator (Laryngo-Tracheal), Topical Anesthesia
CCW
Laryngoscope, Rigid
EPE
Brush, Cleaning, Tracheal Tube
FNC
Tent, Pediatric Aerosol
FOG
Hood, Oxygen, Infant
JAY
Support, Breathing Tube
JOH
Tube Tracheostomy And Tube Cuff
KFZ
Humidifier, Non-Direct Patient Interface (Home-Use)
KGB
Mask, Oxygen, Non-Rebreathing
KHA
Mask, Scavenging
LNZ
Changer, Tube, Endotracheal
MIA
Needle, Spinal, Short Term
MNS
Ventilator, Continuous, Non-Life-Supporting
MNT
Ventilator, Continuous, Minimal Ventilatory Support, Facility Use
MRN
Apparatus, Nitric Oxide Delivery
MRO
Apparatus, Nitric Oxide, Backup Delivery
MZT
Device, Heimlich Maneuver Assist
NFB
Conserver, Oxygen
NHJ
Device, Positive Pressure Breathing, Intermittent
NHK
Resuscitator, Manual, Non Self-Inflating
NMA
Tube, Tracheal, Reprocessed
NMC
Mask, Ventilator, Non-Continuous, Reprocessed
NMR
Needle, Spinal, Short Term, Reprocessed
NNH
Needle, Conduction, Anesthesia, Reprocessed
NOU
Continuous, Ventilator, Home Use
NQY
Ventilator, Continuous, Minimal Ventilatory Support, Home Use
NVO
Spacer, Direct Patient Interface
NVP
Holding Chambers, Direct Patient Interface
NXA
Tracheotomy Care Kit
OBN
Humidifier, Respiratory, Mask (Direct Patient Interface)
OFQ
Anesthesia Kit
OFT
Spinal Epidural Anesthesia Kit
OFU
Spinal Anesthesia Kit
OFV
Regional Anesthesia Kit
OGA
Brachial Plexus Anesthesia Kit
OGB
Caudal Anesthesia Kit
OGC
Continuous Brachial Plexus Block Tray
OGD
Custom Anesthesia Tray
OGE
Epidural Anesthesia Kit
OGF
Glossopharyngeal Anesthesia Kit
OGG
Humidifier Nebulizer Kit
OGH
Laryngoscope Kit
OGI
Nasal Endotracheal Tube Holder Kit
OGJ
Nerve Block Tray
OGL
Oxygen Administration Kit
OLF
Medevac Use Oxygen Generator
ONZ
Mechanical Ventilator
OQU
Airway Monitoring System
PHS
Oral Airway Assist
PMB
External Airway
QAV
High Flow/High Velocity Humidified Oxygen Delivery Device
QBY
Positive Airway Pressure System
QCX
Retrograde Intubation Set
OZR
Intraoral Pressure Gradient Device
QFB
Isocapnic Ventilation Device
SDS
Compression-Based Airway Clearance Device
SDT
Intra-Pulmonary Percussive Vibration (Ipv) Devices
SFP
Ventilator-Compatible Nebulizer
Subpart G—Miscellaneous
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
AN
/
subpart-f—therapeutic-devices
/
CAD
/
K841157
View Source
HALOTHANE VAPORIZER 950, ENFLURANE
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K841157
510(k) Type
Traditional
Applicant
SIEMENS ELEMA AB
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
6/7/1984
Days to Decision
80 days