RUSCH REINFORCED TRACHAEL TUBE CUFFED, STERILE

K955495 · Rusch, Inc. · BTR · Jun 27, 1996 · Anesthesiology

Device Facts

Record IDK955495
Device NameRUSCH REINFORCED TRACHAEL TUBE CUFFED, STERILE
ApplicantRusch, Inc.
Product CodeBTR · Anesthesiology
Decision DateJun 27, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 868.5730
Device ClassClass 2
AttributesTherapeutic

Indications for Use

The device is a single use, sterile, cuffed tracheal tube for tracheal intubation and indicated for airway management.

Device Story

Single-use, sterile, cuffed tracheal tube; used for airway management via tracheal intubation. Device consists of clear, implant-tested PVC tube with encapsulated stainless steel reinforcing spiral; includes graduated markings for intubation depth monitoring; terminated with fully inserted connector. Features low-pressure, high-volume cuff inflated via luer-activated valve, pilot balloon, and inflation lumen. Used by clinicians in hospital settings to maintain patent airway; output is physical airway access; benefits include secure ventilation and airway protection.

Clinical Evidence

Bench testing only; no clinical data provided.

Technological Characteristics

Materials: Implant-tested PVC, stainless steel reinforcing spiral. Design: Cuffed tracheal tube with graduated markings, luer-activated valve, pilot balloon, and inflation lumen. Sizes: 5.0 mm to 11.0 mm ID. Sterilization: Sterile, single-use.

Indications for Use

Indicated for airway management in patients requiring tracheal intubation. Available in sizes 5.0 mm to 11.0 mm internal diameters.

Regulatory Classification

Identification

A tracheal tube is a device inserted into a patient's trachea via the nose or mouth and used to maintain an open airway.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} U RUSCH. INTERNATIONAL Group Regulatory Affairs A Subsidiary of Teleflex Incorporated (USA) K955495 Tall Pines Park Jaffrey, NH 03452 (603) 532-7706 FAX (603) 532-8211 or 6108 JUN 27 1995 To: Whom it may concern ## Substantial Equivalence 510(k) Summary Reference: Rüsch Reinforced Tracheal Tube - Cuffed, sterile The Rüsch Reinforced Endotracheal Tube - Cuffed, sterile for tracheal intubation applied for in this application is substantially equivalent in design, use and materials to the: Sheridan Reinforced Cuffed Tracheal Tube - K844296 SIMS/Concord/Portex Reinforced Cuffed Silicone Tracheal Tube - K830352 NCC/Mallinckrodt Reinforced Tracheal Tube Cuffed currently being marketed and sold in inter-state commerce. The device, which is equivalent to other devices currently being marketed, consists of a clear, implant tested, P.V.C. tube with an encapsulated stainless steel reinforcing spiral. The tube is graduated with multiple centimeter markings to allow easy determination of the intubated length, and is terminated with a fully inserted connector. The tube is fitted with a low pressure, high volume cuff, which is inflated through a luer-activated valve, pilot balloon, inflation tube and lumen in the wall of the main tube. The device is a single use, sterile, cuffed tracheal tube for tracheal intubation and indicated for airway management. It will be available in a variety of sizes from 5.0 mm to 11.0 mm internal diameters in steps of 0.5 mm.. Based upon the equivalence in materials, design and intended use between this tube and others presently being marketed and sold, no difference in safety and effectiveness is forecasted. signed ![img-0.jpeg](img-0.jpeg) Authorized, Regulatory Affairs Department October 10, 1995
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...