AS/3 NMT MODULE

K955026 · Datex Medical Instrumentation, Inc. · KOI · Apr 28, 1997 · Anesthesiology

Device Facts

Record IDK955026
Device NameAS/3 NMT MODULE
ApplicantDatex Medical Instrumentation, Inc.
Product CodeKOI · Anesthesiology
Decision DateApr 28, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 868.2775
Device ClassClass 2

Indications for Use

The product is designed to be used for monitoring relaxation of patient during and after anesthesia and for regional block stimulation for nerve location. The intended environment of use is anesthesia department, including operation rooms (OR) and post-anesthesia care units (PACU) etc.

Device Story

AS/3 M-NMT module; component of AS/3 anesthesia monitoring system. Function: neuromuscular transmission monitoring and nerve location via regional block stimulation. Operation: module stimulates patient; measures response; transmits data to AS/3 anesthesia or compact monitor central unit. Central unit software calculates NMT values, displays data, manages trends, and provides monitoring features. Used in OR and PACU by anesthesia clinicians. Output assists in assessing patient relaxation levels and guiding nerve block procedures.

Clinical Evidence

No clinical data provided; bench testing only.

Technological Characteristics

Modular anesthesia monitoring component; hardware-based stimulation and response measurement; integrates with AS/3 anesthesia or compact monitor central unit; software-driven calculation and display.

Indications for Use

Indicated for monitoring neuromuscular relaxation in patients undergoing anesthesia and for regional block stimulation for nerve location in clinical settings including OR and PACU.

Regulatory Classification

Identification

An electrical peripheral nerve stimulator (neuromuscular blockade monitor) is a device used to apply an electrical current to a patient to test the level of pharmacological effect of anesthetic drugs and gases.

Submission Summary (Full Text)

{0} K955086 510(k) SUMMARY 23.02.96 APR 28 1997 Datex Division Instrumentarium Corp. P.O. Box 446 FIN-00101 Helsinki Finland Tel: +358 0 39411 Fax: +358 0 1463310 Contact person: Rauno Ruoho # PRODUCT NAMES Device name: $\mathrm{AS} / 3^{\mathrm{TM}}$ M-NMT Common name: Neuromuscular transmission Device # DESCRIPTION OF THE DEVICE The AS/3™ NMT Module is a part of the modular anesthesia monitoring system AS/3™. It provides relaxation measurement of patient. The product is designed to be used for monitoring relaxation of patient during and after anesthesia and for regional block stimulation for nerve location. The intended environment of use is anesthesia department, including operation rooms (OR) and post-anesthesia care units (PACU) etc. The NMT measurement hardware is in the NMT module. The NMT Module stimulates the patient controlled by the AS/3™ Anaesthesia or Compact Monitor central unit. Then the NMT Module measures the response of the stimulation and sends it to the AS/3™ Anaesthesia or Compact Monitor central unit. The AS/3™ monitor software receives the responses from the NMT module, calculates the NMT values, displays the NMT values, handles NMT trending and NMT monitor features.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...