K140370 · Besmed Health Business Corp · CAP · Jun 19, 2014 · Anesthesiology
Device Facts
Record ID
K140370
Device Name
DISPOSABLE PRESSURE MANOMETER
Applicant
Besmed Health Business Corp
Product Code
CAP · Anesthesiology
Decision Date
Jun 19, 2014
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 868.2600
Device Class
Class 2
Attributes
Pediatric
Indications for Use
To provide visual indication of a patient's airway pressure during ventilation. It may be attached to the manometer port or proximal port on ventilation devices such as resuscitation bags, CPAP mask, or CPAP circuits. For patients that the clinician desires to monitor or measure airway or circuit pressure, including neonates to adults. Home, Physician office, Hospital, Subacute Institutions, Emergency services or anywhere measurement of airway pressure is desired.
Device Story
Disposable pressure manometer provides visual indication of airway pressure during ventilation. Device connects to sampling/pressure ports on resuscitation bags, hyperinflation bags, CPAP masks, or CPAP circuits via flexible nipple. Mechanical design features clear housing, internal spring, and float indicator; positive pressure in circuit displaces float against spring, displaying pressure on calibrated scale (0-40 or 0-60 cm H2O). Used by clinicians in hospitals, clinics, emergency services, or home settings. Provides real-time visual feedback to assist clinicians in monitoring airway pressure, helping to avoid over-pressurization via a fixed leak mechanism. Benefits include simple, portable, single-patient use monitoring of ventilation pressures.
Clinical Evidence
Bench testing only. No clinical data provided. Testing included comparative pressure accuracy across the full range, 5-year simulated age testing, environmental testing (high/low temperature and humidity per MIL-STD-810E), and mechanical drop testing. Results demonstrated no statistical difference in accuracy performance compared to the predicate device.
Technological Characteristics
Mechanical airway pressure monitor. Components: clear housing, float, spring, pressure scale. Materials: biocompatible for limited duration (<24 hours) indirect/tissue contact. Energy source: pneumatic (passive). Connectivity: none. Sterilization: non-sterile. Models: 0-40 cm H2O and 0-60 cm H2O ranges. Features fixed leak for over-pressurization protection.
Indications for Use
Indicated for patients from neonates to adults requiring airway or circuit pressure monitoring during ventilation. Used in home, clinical, hospital, and emergency settings. No specific contraindications listed.
Regulatory Classification
Identification
An airway pressure monitor is a device used to measure the pressure in a patient's upper airway. The device may include a pressure gauge and an alarm.
Predicate Devices
Engineered Medical Systems - Pressure Monitor (K003497)
Submission Summary (Full Text)
{0}------------------------------------------------
# JUN 1 9 2014
# 510(k) Summary Page 1 of 4
| Date Prepared: | 19-Jun-2014 | |
|-------------------------------------------------------------------------------------------------------------|-------------------------------------------------------------|--|
| Besmed Health Business Corp.<br>No. 5, Lane 116, Wu-Kong 2nd Rd,<br>Wu-Ku District, New Taipei City, Taiwan | Tel - 011-886-2-2290-3959<br>Fax - 011-886-2-2299-9076 | |
| Official Contact: | Winnie Chung<br>Regulatory Affairs Associate | |
| Proprietary or Trade Name: | Disposable Pressure Manometer | |
| Common/Usual Name: | Airway Pressure Monitor | |
| Classification Name: | 21CFR 868.2600<br>CAP - Airway Pressure Monitor<br>Class II | |
| Predicate Devices: | K003497 - Engineered Medical Systems - Pressure Monitor | |
# Device Description:
The Besmed disposable pressure manometer is a means of providing visual indication of patient airway pressure during ventilation.
The device consists of:
- 1. A flexible nipple for attachment to a sampling / pressure port.
- 2. Clear housing with a printed pressure scale
- 3. A float with indicator
- 4. Spring
When positive pressure is present in the ventilation device, the manometer displays the pressure in the "circuit". The proposed design incorporates a calibrated spring, which has demonstrated reasonable accuracy over the expected clinical pressure range - 0-60 cm H2O.
Besmed intends offer three (3) models / styles of their disposable pressure manometer.
They are identical in design, function and materials. The differences are:
- Pressure range .
- 0 0 60 cm H2O
- 0 40 cm H2O
- · Rationale some devices which may use a pressure manometer do not produce as high a pressure and the user often would like a lower limit pressure design
- Note the accuracy and performances are identical
- . Indicator strip
.
- O All models have the pressure range embossed on the housing
- o A color strip / indicator may also be included to indicate the pressure
{1}------------------------------------------------
# 510(k) Summary Page 2 of 4 19-Jun-2014
It is a single patient, disposable, packaged non-sterile device.
### Indications for Use:
To provide visual indication of a patient's airway pressure during ventilation. It may be attached to the manometer port or proximal port on ventilation devices such as resuscitation bags, hyperinflation bags, CPAP mask, or CPAP circuits, For patients that the clinician desires to monitor or measure airway or circuit pressure, including neonates to adults. Home. Physician office, Hospital, Sub-acute Institutions, Emergency services or anywhere measurement of airway pressure is desired.
### Substantial Equivalence Discussion:
Table 1 compares the key features of the proposed Besmed Disposable Pressure Manometer with the identified predicate and demonstrates that the device can be found to be substantially equivalent. In summary one can conclude that substantial equivalence is met based upon the following:
### Indications for Use -
The indications for use are identical for the proposed device when compared to the predicate -K003497 - EMS pressure manometer.
Discussion - Each device is indicated for use to measure pressure in a circuit or airway.
### Technology and construction -
The design, components, shape, size, etc., are equivalent to the predicate - K003497 - EMS pressure manometer.
Discussion ~ The design is simple housing with a float that sits on a spring that goes up or down based upon the pressure in the device. It has markings to indicate the pressure observed as well as a fixed leak to avoid over pressurization.
### Environment of Use -
The environments of use are identical to predicate - K003497 - EMS pressure manometer. Discussion - The environments of use are identical to the predicate - K003497 - EMS pressure manometer.
### Patient Population -
The patient population is defined as patient where the clinician wants to measure or monitor circuit or airway pressure. The specific patient population is the same as the device to which it is attached which could be neonates to adults.
Discussion - The patient populations are equivalent to the predicate - K003497 - EMS pressure manometer.
{2}------------------------------------------------
# 510(k) Summary
| Attribute | Predicate | Proposed |
|--------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| | EMS – K003497 Pressure Manometer | Besmed DPM |
| Indications for Use | To provide visual indication of a<br>patient's airway pressure during<br>ventilation. It may be attached to the<br>manometer port or proximal port on<br>ventilation devices such as resuscitation<br>bags, hyperinflation bags, CPAP mask,<br>or CPAP circuits. | To provide visual indication of a<br>patient's airway pressure during<br>ventilation. It may be attached to the<br>manometer port or proximal port on<br>ventilation devices such as resuscitation<br>bags, hyperinflation bags, CPAP mask,<br>or CPAP circuits. |
| Patient population | Patient that the clinician desires to<br>monitor or measure pressure, neonates to<br>adults | Patient that the clinician desires to<br>monitor or measure pressure. |
| Environments of use | Home, Physician office, Hospital, Sub-<br>acute Institutions, Emergency services or<br>anywhere measurement of airway<br>pressure is desired. | Home, Physician office, Hospital, Sub-<br>acute Institutions, Emergency services or<br>anywhere measurement of airway<br>pressure is desired. |
| Prescriptive | Yes | Yes |
| Single patient, disposable | Yes | Yes |
| Connects to a sampling<br>port of any device, i.e.<br>resuscitator, etc. | It may be attached to the manometer port<br>or proximal port on ventilation devices<br>such as resuscitation bags, hyperinflation<br>bags, CPAP mask, or CPAP circuits. | It may be attached to the manometer port<br>or proximal port on ventilation devices<br>such as resuscitation bags, hyperinflation<br>bags, CPAP mask, or CPAP circuits. |
| Basic components | Housing<br>Float<br>Spring<br>Pressure markings<br>Fixed leak in the unit | Housing<br>Float<br>Spring<br>Pressure markings<br>Fixed leak in the unit |
| Pressure range | 0 - 50 cm H₂O | 0 - 60 cm H₂O |
| Models | Only one | Three 0-40, 0-60 with indicator stripe<br>0-60 with embossed pressure but no<br>indicated stripe |
| Performance testing | Accuracy<br>• ± 1 cm H₂O from 0-10 cm H₂O<br>• ± 2 cm H₂O from 10-40 cm H₂O<br>• ± 3 cm H₂O above 40 cm H₂O | Accuracy<br>• ± 1 cm H₂O from 0-10 cm H₂O<br>• ± 2 cm H₂O from 10-40 cm H₂O<br>• ± 3 cm H₂O above 40 cm H₂O<br>Age Testing – 5 years<br>Pre and post- exposure<br>Environmental Testing<br>High / Low and Humidity conditions<br>Drop test |
| Biocompatibility | | • External Communication (Indirect<br>contact) for all materials not in<br>direct contact<br>• Tissue communicating<br>• Limited duration (<24 hours)<br>• Identical materials to Besmed<br>predicate |
Table 1 - Comparison to Predicates
-
·
{3}------------------------------------------------
# 510(k) Summary Page 4 of 4 19-Jun-2014
## Non-Clinical Testing Summary -
We performed a number of tests including comparative pressure accuracy and the results demonstrated equivalent performance demonstrating the proposed device is equivalent to the -K003497 - EMS pressure manometer.
Testing included:
- . Accuracy of pressure across the full pressure range to meet the pass / fail criteria
- Comparative accuracy testing showed no statistical difference in accuracy performance . between the proposed device and the predicate, K003497 - EMS
- . Age testing simulated to be equivalent to 5 years
- . Environmental testing at high and low temperatures (MIL-STD-810E)
- Mechanical testing Drop test .
All testing demonstrated that the proposed device is substantially equivalent to the predicate device.
### Substantial Equivalence Conclusion:
The proposed device has been found to be substantially equivalent to the predicate. Differences between the proposed device and the predicate do not raise new questions of safety or efficacy.
{4}------------------------------------------------
Image /page/4/Picture/0 description: The image shows the logo for the Department of Health and Human Services (HHS) in the United States. The logo features a stylized depiction of an eagle with three stripes forming its body and wing. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular pattern around the eagle.
Public Health Service
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
June 19, 2014
Besmed Health Business Corp. c/o Paul Dryden Consultant No. 5. Lane 116. Wu-Kong 2nd Rd. Wu-Ku District, New Taipei City, Taiwan
Re: K140370
Trade/Device Name: Disposable Pressure Manometer (RE-21466, RE-21464 and RE-21460) Regulation Number: 21 CFR 868.2600 Regulation Name: Airway Pressure Manometer Regulatory Class: Class II Product Code: CAP Dated: May 10, 2014 Received: May 13, 2014
Dear Mr. Dryden:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration. Ilsting of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRFI does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA). it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{5}------------------------------------------------
# Page 2 -- Paul Dryden
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely yours.
. . . . Tejashri Purohit-Sheth, M.D. Tejashri Purofit-Sheth, M.D. Clinical Deputy Director DAGRID/ODE/CDRH FOR
Erin J. Keith. MS Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control, and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{6}------------------------------------------------
DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
# Indications for Use
Form Approved: OMB No. 0910-0120 Expiration Date: December 31, 2013 See PRA Statement on last page.
### 510(k) Number (if known) K140370
Device Name Disposable Pressure Manometer
#### Indications for Use (Describe)
To provide visual indication of a patient's airway pressure during ventilation. It may be attached to the manometer port or proximal port on ventilation devices such as resuscitation bags, CPAP mask, or CPAP circuits. For patients that the clinician desires to monitor or measure airway or circuit pressure, including neonates to adults. Home, Physician office, Hospital, Subacute Institutions, Emergency services or anywhere measurement of airway pressure is desired.
Type of Use (Select one or both, as applicable)
区 Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
## PLEASE DO NOT WRITE BELOW THIS LINE -- CONTINUE ON A SEPARATE PAGE IF NEEDED,
# FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
Anya C. Harry -S 2014.06.19 09:14:08 -04'00'
FORM FDA 3881 (9/13)
PSC Publishone Scrinces (101) 445-674)
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Guidance alerts
New and changed FDA guidance documents, emailed as a daily digest.
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.
Copy this now. It will not be shown again.
Connected apps
Apps you authorized through browser sign-in. Disconnecting revokes their access immediately.
Learn the FDA Browser
Two short videos show you everything — or skip straight to the written tutorial if you'd rather read. You can reopen this any time from the ? button in the top bar.
Part 1 — Search, results, and everyday workflows 16 min
Part 2 — Embeddings: the galaxy map 3 min
1. Search: exact and fuzzy
Type a phrase like "coronary artery calcification" into the search box. You get two kinds of results. Exact results match the literal phrase — prefix searches work ("coronary artery calcificati") but suffix searches do not. Fuzzy results match on the meaning and intent of your phrase rather than the exact words, and are sorted by relevance score. Hover over the Exact or Fuzzy badge on any row to see exactly why it matched.
Use the checkboxes above the results to narrow: SaMD keeps only Software as a Medical Device, AI / ML keeps only devices with AI.
Exact vs. fuzzy search: what's the difference?
Exact matches on the literal phrase (prefix search works, suffix does not). Fuzzy matches on the meaning and intent of the phrase rather than the exact words. Hover over the badge on any row to see why it matched.
You search "coronary artery calcification" and want only software devices with AI. What two filters do you apply?
Narrow by SaMD (Software as a Medical Device), then narrow by AI/ML (devices with AI).
2. The results table
Scroll right in the results table. The intended use is extracted for you — no need to open the PDF. The device story gives a high-level snapshot of what the device does and how it's used. The AI Performance sub-table shows each output name, acceptance criteria, observed values, and development/test dataset descriptions — the same format Innolitics uses for regulatory strategy outputs, and the fastest high-level fingerprint of an AI device. It is AI-generated but has been very reliable in practice.
Where do you find a device's intended use without opening the PDF?
Scroll right in the search results table. The intended use column is extracted for you; no need to dig into the 510(k) summary PDF.
What does the AI Performance sub-table show, and why is it useful?
Output name, acceptance criteria, observed values, development dataset description, and test dataset description. It's the same format we use for regulatory strategy output and Fast 510(k) input, and the fastest high-level fingerprint of an AI device. AI-generated but reliable in practice.
3. Judging fuzzy relevance
Fuzzy results trail off in relevance as you scroll. Use three signals to decide how far down to go: the fuzzy badge explanations, the intended use column, and whether your target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, you're past the relevant zone. A top hit with a low score (~0.4) and a stretched explanation is a hint the closest predicates are far away — the project may be headed for De Novo. Note the fuzzy search is a pattern match: it doesn't handle negation ("not") well, and hardware devices can appear — filter by SaMD/AI ML to cut them.
How do you judge how far down fuzzy search results to go?
Use the relevancy signals: the fuzzy badge explanations, the intended use column, and whether the target output (e.g., Cobb angle) still appears in the AI Performance sub-table. Once it stops appearing, results are trailing off in relevancy.
4. Device detail page: chat and citations
Click a device name to open its detail page: device facts on the left, a chat window on the right. Ask something like "Describe the training data". The answer carries little citation bubbles — click one to jump to the highlighted passage in the source PDF, so you can verify every AI answer against the document. There's also a Download PDF button for sharing.
How do you verify an AI chat answer on the device detail page?
Click the citation bubbles to jump to the relevant highlight in the source document.
Reading rule for every project: how many summaries do you read in full?
At least the three most relevant 510(k) or De Novo summaries, in full. After that, use targeted chat questions to confirm your memory quickly. The tool supports this professional habit — it doesn't replace it.
5. Side-by-side comparison
Select multiple rows in the results table (aim for under ~10), then open the PDF Viewer tab. Ask one question — it goes to all selected devices in parallel, each with citations. This is the fastest way to compare and contrast devices: training data, PCCP scope, how they handled adding new scanners, and so on.
What does the side-by-side PDF viewer mode do?
Select multiple devices, open the PDF viewer tab, and ask one question (e.g., "Describe the training data"). It queries all selected devices simultaneously with citations, so you can compare and contrast quickly.
6. Collections
With rows selected, go to the Collections tab and create a labeled collection (e.g., "Cobb Angle Project"). Reload that selection any time — before a client call, pull up the collection and ask questions across all of its devices at once.
How do you save a set of selected devices for later use?
Select the rows, go to the Collections tab, and create a labeled collection (e.g., "Cobb Angle Project"). You can reload the selection anytime and carry it into the PDF viewer and other tabs that support selections.
7. Product codes and the regulations tree
Click a product code in the results to jump to it in the regulations tree — identification text, sibling product codes, and devices you can open in a PDF viewer on the right. Click a regulation number to see its identification, special controls, and related product codes. You can also search by product code or regulation number at the top of the tree. Always read the special controls if any exist for your device — it broadens your search and sharpens pre-kickoff research.
What can you do from the regulations tree view?
Browse product codes and regulation numbers, read the identification text and special controls, browse sibling product codes, open device PDFs on the right, and search by product code or regulation number at the top of the tree.
8. Chart view
Click Show Chart and segment by regulation number (or product code) to see which regulations dominate your result set. Clicking a regulation takes you into the regulations tree. Great for spotting that most matches are, say, hardware laparoscopic devices — a cue to go back and filter.
How do you see which regulations dominate a search result set?
Click "Show Chart" and segment by Regulation Number. Clicking a regulation takes you to the regulations tree.
9. The predicate graph
Open the Predicates tab for a family-tree view of predicate relationships. Click a node to trace its parents and children; selections from search carry over pre-selected. Commonly predicated devices are worth reading — a lot of people predicated them for a reason. The visual lineage is also handy on client calls, e.g. to show how a predicate family evolved and justify why your predicate still holds.
In the predicate graph, why are commonly predicated devices worth reading?
A lot of people predicated them for a reason. Clicking a node traces parents and children, and selections from search carry over pre-selected.
10. Embeddings: the galaxy map
The Embeddings tab plots every matching document in a 2-D "galaxy map" where semantically similar devices cluster together. Hover or click clusters to explore, and let AI label the clusters for you. Embeddings beat product codes for grouping: two devices can carry different product codes (LLZ vs. QIH) yet do the same thing — the embedding captures the meaning of the intended use and device story. This is also exactly how retrieval-augmented generation (RAG) works under the hood, and it makes a great visual on client calls.
Try it yourself
Head to the search page and work through a few of these AI/ML fuzzy searches to build intuition: perivascular fat on CT · aortic valve calcification opportunistic screening on noncontrast CT · breast cancer prediction on digital pathology slides · autism detection · gestational age prediction · a hearing aid that can also detect a pulse · foundation model based analysis of ECG · large language models · penetration test. Watch how the relevance scores, intended use, and AI Performance tables tell you when results stop being meaningful.