AEROGEAR ASTHMA ACTION KIT

K964130 · Monaghan Medical Corp. · BZH · Jan 10, 1997 · Anesthesiology

Device Facts

Record IDK964130
Device NameAEROGEAR ASTHMA ACTION KIT
ApplicantMonaghan Medical Corp.
Product CodeBZH · Anesthesiology
Decision DateJan 10, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 868.1860
Device ClassClass 2
AttributesTherapeutic

Intended Use

The AeroGear Asthma Action Kit is a product containing the AeroChamber Aerosol Holding Chamber, TruZone Peak Flow Meter, a fanny pack and educational materials used in an asthma management program. This kit is intended to be marketed to hospitals, outpatient clinics and physicians.

Device Story

AeroGear Asthma Action Kit; contains AeroChamber Aerosol Holding Chamber, TruZone Peak Flow Meter, fanny pack, and educational materials. Used in clinical settings (hospitals, outpatient clinics) by physicians to facilitate asthma management programs. Kit components function as established in their respective clearances; AeroChamber delivers aerosolized medication; TruZone measures peak expiratory flow. Output used by clinicians to monitor patient respiratory status and manage asthma treatment plans.

Clinical Evidence

No clinical data; bench testing only via reliance on predicate device clearances.

Technological Characteristics

Kit assembly of two cleared medical devices. No modifications to individual device function or materials. Standalone components.

Indications for Use

Indicated for use in asthma management programs for patients requiring aerosol medication delivery and peak flow monitoring.

Regulatory Classification

Identification

A peak-flow meter for spirometry is a device used to measure a patient's maximum ventilatory flow rate.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} K964130 JAN 10 1997 # SECTION 2 - SUMMARY AND CERTIFICATION ## 510(k) SUMMARY Monaghan Medical Corporation 5 Latour Ave., Suite 1600 P.O. Box 2805 Plattsburgh, NY 12901-0299 Phone: 518-561-7330 Fax: 518-561-5660 Contact: James A. Cochie QA/RA Manager **Date Prepared:** October 1, 1996 **Device Proprietary Name:** AeroGear Asthma Action Kit **Device Classification name:** Unknown **Legally Marketed Device Identity:** AeroChamber w/FLOWSIGnal, 510(k) #872037/A TruZone Peak Flow Meter, 510(k) #926307 **Device Description:** The AeroGear Asthma Action Kit is a product containing the AeroChamber Aerosol Holding Chamber, TruZone Peak Flow Meter, a fanny pack and educational materials used in an asthma management program. This kit is intended to be marketed to hospitals, outpatient clinics and physicians. The two devices indicated above are currently marketed devices which have been cleared through the 510(k) process.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...