Diaphragmatic/Phrenic Nerve Laparoscopically-Implanted Stimulator

Page Type
Product Code
Definition
The device is intended for use in patients with stable, high spinal cord injuries with stimulatable diaphragms, but who lack control of their diaphragms. The device is indicated to allow the patients to breathe without the assistance of a mechanical ventilator for at least 4 continuous hours a day. For use only in patients 18 years of age or older.
Physical State
implanted electrodes, stimulator control, clinical programming station
Technical Method
provides electrical stimulation for diaphragm movement
Target Area
diaphragm
Review Panel
Anesthesiology
Submission Type
HDE - Humanitarian Device Exemption
Device Classification
F
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
Yes
Third Party Review
Not Third Party Eligible

No Linked CFR Text

The FDA has not linked product code OIR to any particular section of the CFR (Code of Federal Regulations). There are multiple reasons why this might be the case:

  • The product code was created for a class III submission that does not follow the normal PMN or PMA path - e.g., for a device that falls under HDE (Humanitarian Device Exemption) or EUA (Emergency Use Authorization).
  • The FDA has generated the product code for an existing Class III device, as a result of a PMA supplement that modifies the device in a way that it can't fit under the existing product code originally assigned
  • The product code was created for internal use at the FDA, and not for classification or regulatory-related purposes.

Diaphragmatic/Phrenic Nerve Laparoscopically-Implanted Stimulator

Page Type
Product Code
Definition
The device is intended for use in patients with stable, high spinal cord injuries with stimulatable diaphragms, but who lack control of their diaphragms. The device is indicated to allow the patients to breathe without the assistance of a mechanical ventilator for at least 4 continuous hours a day. For use only in patients 18 years of age or older.
Physical State
implanted electrodes, stimulator control, clinical programming station
Technical Method
provides electrical stimulation for diaphragm movement
Target Area
diaphragm
Review Panel
Anesthesiology
Submission Type
HDE - Humanitarian Device Exemption
Device Classification
F
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
Yes
Life-Sustain/Support Device
Yes
Third Party Review
Not Third Party Eligible

No Linked CFR Text

The FDA has not linked product code OIR to any particular section of the CFR (Code of Federal Regulations). There are multiple reasons why this might be the case:

  • The product code was created for a class III submission that does not follow the normal PMN or PMA path - e.g., for a device that falls under HDE (Humanitarian Device Exemption) or EUA (Emergency Use Authorization).
  • The FDA has generated the product code for an existing Class III device, as a result of a PMA supplement that modifies the device in a way that it can't fit under the existing product code originally assigned
  • The product code was created for internal use at the FDA, and not for classification or regulatory-related purposes.