PEAK EXPIRATORY FLOW METER

K912866 · Health Products, Inc. · BZH · Aug 13, 1992 · Anesthesiology

Device Facts

Record IDK912866
Device NamePEAK EXPIRATORY FLOW METER
ApplicantHealth Products, Inc.
Product CodeBZH · Anesthesiology
Decision DateAug 13, 1992
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 868.1860
Device ClassClass 2

Device Story

Personal Best Peak Flow Meter; handheld device for measuring peak expiratory flow rate (PEFR). Patient exhales into device; mechanical mechanism measures airflow; provides numerical output on scale. Used by patients for self-monitoring of respiratory function; assists in asthma management and clinical decision-making regarding medication adjustments. Portable design; intended for home or clinical use.

Clinical Evidence

No clinical data provided in the document; bench testing only.

Technological Characteristics

Mechanical peak flow meter; handheld form factor; non-electronic; no software or algorithm; no external energy source.

Regulatory Classification

Identification

A peak-flow meter for spirometry is a device used to measure a patient's maximum ventilatory flow rate.

Submission Summary (Full Text)

{1} DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service AUG 13 1992 Food and Drug Administration 1390 Piccard Drive Rockville, MD 20850 Mr. Frank J. Alvino Healthscan Products, Inc. 908 Pompton Avenue Unit B2 Cedar Grove, New Jersey 07009-1292 Re: K912866/D Personal Best Peak Flow Meter Dated: July 15, 1992 Received: July 17, 1992 Regulatory Class: II Dear Mr. Alvino: We have reviewed your Section 510(k) notification of intent to market the device referenced above and we have determined the device is substantially equivalent to devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments. You may, therefore, market the device, subject to the general controls provisions of the Federal Food, Drug, and Cosmetic Act (Act). The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, and labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (Premarket Approval) it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 895. In addition, the Food and Drug Administration (FDA) may publish further announcements concerning your device in the Federal Register. Please note: this response to your premarket notification submission does not affect any obligation you might have under the Radiation Control for Health and Safety Act of 1968, or other Federal laws or regulations. This letter immediately will allow you to begin marketing your device as described. An FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and permits your device to proceed to the market, but it does not mean that FDA approves your device. Therefore, you may not promote or in any way represent your device or its labeling as being approved by FDA. If you desire specific advice on the labeling for your device, please contact the Division of Compliance Operations, Device Labeling Compliance Branch (HFZ-326) at (301) 427-1165. Other general information on your responsibilities under the Act, may be obtained from the Division of Small Manufacturers Assistance at their toll free number (800) 638-2041 or at (301) 443-6597. Abhijit Acharya Abhijit Acharya, Ph.D. Director Division of Cardiovascular, Respiratory, and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health ①
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...