3mensio Workstation

K250330 · Pie Medical Imaging BV · QIH · Nov 3, 2025 · Radiology

Device Facts

Record IDK250330
Device Name3mensio Workstation
ApplicantPie Medical Imaging BV
Product CodeQIH · Radiology
Decision DateNov 3, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesAI/ML, Software as a Medical Device, Real-World Evidence

Real-World Evidence

SubmissionDeviceSponsorRWD SourcesRWE Use SummaryKey Tags
K250330 · Nov 3, 20253mensio WorkstationPie Medical Imaging BVRetrospective MSCT clinical datasetsRetrospective clinical MSCT datasets from 65 patients were used to evaluate the accuracy and performance of the device's automated segmentation and measurement algorithms against expert-derived ground truth.Retrospective cohort; MSCT; Algorithm validation; Clinical performance

Clinical Evidence

Study DesignPopulationComparatorKey Endpoints
Multi-centric observational cohort study; Retrospective observational cohort study65 patients indicated for valvular intervention (age 38-99, 50% female); Sample Size: 65 patients; Number of Sites: Multi-centricExpert manual measurements (ground-truth)Dice scores for segmentation accuracy; Bland-Altman analysis and ICC for measurement accuracy

AI Performance

OutputAlgorithmAcceptanceObservedDev DSDev ReadersTest DSTest Readers
Cardiovascular structure segmentation——Dice scores: 0.94 ± 0.07 (mitral annulus), 0.87 ± 0.12 (tricuspid annulus); Average distance: -/- 0.64 ± 1.07 mm——Multi-centric observational cohort study: 65 patients indicated for valvular intervention.>1 (experts)
Cardiovascular structure measurements——ICC: 0.99 (aortic annulus), 0.94+ (mitral annulus), 0.97+ (tricuspid annulus)——Multi-centric observational cohort study: 65 patients indicated for valvular intervention.>1 (experts)

Indications for Use

Standalone diagnostic bioimaging software is intended to measure and visualize cardiovascular structures.

Device Story

3mensio Workstation is a software package for advanced visualization and quantitative analysis of cardiovascular images (CT, X-Ray, ultrasound). It processes DICOM images to segment cardiovascular structures, detect centerlines, and perform measurements (diameters, lengths, areas, volumes, angles). The device supports pre-operational planning, postoperative evaluation, and clinical diagnosis. It is used by cardiologists and radiologists in clinical settings, deployed as a standalone PC application or a web-based solution (network/cloud). The software includes machine learning features for automated segmentation and measurement. Healthcare providers use the output—visualizations, measurements, and reports—to assist in clinical decision-making for cardiovascular interventions and surgery. Benefits include reliable, efficient preparation for vascular and structural heart procedures through automated quantification and visualization.

Clinical Evidence

Bench testing only. Multi-centric observational cohort study using 65 MSCT datasets (age 38-99, 50% female) from diverse CT manufacturers. Primary endpoints: segmentation accuracy (Dice score) and measurement agreement (Bland-Altman, ICC) against expert manual ground truth. Results: Dice scores 0.94 ± 0.07 (mitral annulus), 0.87 ± 0.12 (tricuspid annulus); ICC values 0.99 (aortic annulus), ≥0.94 (mitral), ≥0.97 (tricuspid). Performance met all predefined acceptance criteria, showing high accuracy and reliability comparable to the predicate device.

Technological Characteristics

Software as a medical device (SaMD). Deployment: standalone PC (Windows) or web-based (network/cloud). Data: DICOM (CT, X-Ray, 2D/3D Ultrasound). Features: segmentation (AI/ML and manual), centerline detection, visualization (MPR, Volume Rendering, MIP, etc.), and measurement tools. Standards: ISO 13485, ISO 14971, IEC 62304, IEC 62366-1, IEC 82304-1. Cybersecurity measures implemented for web/cloud access.

Indications for Use

Indicated for advanced visualization and quantitative analysis for diagnostics in cardiology or radiology, enabling visualization and measurement of heart and vessel structures for pre-operational planning/sizing for cardiovascular interventions/surgery, postoperative evaluation, and support of clinical diagnosis by quantifying coronary artery dimensions and calcifications (calcium scoring).

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Predicate Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION November 3, 2025 Pie Medical Imaging B.V. Annemiek Bouts Regulatory Affairs Coordinator Philipsweg 1 Maastricht, Limburg 6227 AJ Netherlands Re: K250330 Trade/Device Name: 3mensio Workstation Regulation Number: 21 CFR 892.2050 Regulation Name: Medical image management and processing system Regulatory Class: Class II Product Code: QIH, LLZ Dated: September 29, 2025 Received: September 29, 2025 Dear Annemiek Bouts: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K250330 - Annemiek Bouts Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory- {2} K250330 - Annemiek Bouts Page 3 assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, Jessica Lamb Assistant Director Imaging Software Team DHT8B: Division of Radiologic Imaging Devices and Electronic Products OHT8: Office of Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. Submission Number (if known) K250330 Device Name 3mensio Workstation Indications for Use (Describe) Standalone software for medical image analysis intended for advanced visualization and quantitative analysis for diagnostics in the field of cardiology or radiology by means of enabling visualization and measurement of structures of the heart and vessels for: - Pre-operational planning and sizing for cardiovascular interventions and surgery - Postoperative evaluation - Support of clinical diagnosis by quantifying dimensions in coronary arteries - Support of clinical diagnosis by quantifying calcifications (calcium scoring) To facilitate the above, the 3mensio Workstation provides general functionality such as: - Segmentation of cardiovascular structures - Automatic and manual centerline detection - Visualization and image reconstruction techniques: 2D review, Volume Rendering, MPR, Curved MPR, Stretched CMRP, Slabbing, MIP, AIP, MinIP - Measurement and annotation tools - Reporting tools Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov “An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number.” {4} PIE MEDICAL IMAGING 510(k) Summary – K250330 3mensio Workstation 510(k) Summary K250330 3mensio Workstation Pie Medical Imaging BV # I - General Information Submitter/Owner Name: Pie Medical Imaging BV Address: Demertdwarsstraat 8A01, 6227 AK Maastricht, The Netherlands Phone Number: +31 43 32 81 328 Contact Person: Annemiek Bouts, Regulatory Affairs Coordinator Email Address: regulatory@pie.nl Trade Name: 3mensio Workstation Classification: - Regulation Name: Medical Image Management and Processing System - Regulation Class: Class II - Regulation Number: 21 CFR 892.2050 - Classification Product Code: QIH, LLZ Predicate Devices: - Primary predicate device: 3mensio Workstation (K153736, 21 CFR 892.2050, LLZ) - Secondary predicate device: TOMTEC-ARENA (K213544, 21 CFR 892.2050, LLZ, QIH) # II - Device Description 3mensio Workstation is an image post-processing software package for advanced visualization and analysis for diagnostics in the field of cardiology and radiology and offers functionality to view CT/X-Ray angiographic and ultrasound images, to segment cardiovascular structures in these images and to analyze and quantify these cardiovascular structures and to present the results in different formats. 3mensio Workstation can be deployed as a web-based solution intended for usage in a network or cloud environment or as a standalone package and runs on a PC with a Windows operating system. It can read DICOM images from an accessible file system, hard disk (local directory), or (indirectly) received from the CT or PACS system. 3mensio Workstation provides the functionality to import the DICOM images and to organize the loaded DICOM images into patients, studies, and series. 3mensio Workstation contains two analysis modules: 3mensio Vascular and 3mensio Structural Heart: - 3mensio Vascular enables assessment of vessels and can help to measure calcifications, aneurysms and other anomalies to quickly and reliably prepare for various types of vascular procedures. - 3mensio Structural Heart enables assessment and measurement of different structures of the heart, e.g., the heart valves, coronary arteries and the ventricles. It provides analysis of different approach routes to cardiovascular structures for replacement or repair procedures. In addition, it can help in the quantification of calcifications. Results can be displayed on the screen, printed, or saved in a variety of formats to hard disk, network or PACS system. Results and clinical images with overlay can also be printed as a hardcopy and exported in various electronic formats. # III - Intended Use and Indications for Use ## Intended Use Standalone diagnostic bioimaging software is intended to measure and visualize cardiovascular structures. ## Indications for Use Standalone software for medical image analysis intended for advanced visualization and quantitative analysis for diagnostics in the field of cardiology or radiology by means of enabling visualization and measurement of the heart and vessels for: - Pre-operational planning and sizing for cardiovascular interventions and surgery - Postoperative evaluation - Support of clinical diagnosis by quantifying dimensions of coronary arteries - Support of clinical diagnosis by quantifying calcifications (calcium scoring) Pie Medical Imaging BV {5} PIE MEDICAL IPRIGHTS 510(k) Summary – K250330 3mensio Workstation To facilitate the above, the 3mensio Workstation provides general functionality such as: - Segmentation of cardiovascular structures - Automatic and manual centerline detection - Visualization and image reconstruction techniques: 2D review, Volume Rendering, MPR, Curved MPR, Stretched CMPR, Slabbing, MIP, AIP, MinIP - Measurement and annotation tools - Reporting tools ## IV - Substantial equivalence comparison The devices 3mensio Workstation (K153736) and TOMTEC-ARENA (K213544) have been selected as predicate devices for 3mensio Workstation. The selected devices have technological features and characteristics comparable to 3mensio Workstation and are intended to be used by or under supervision of a cardiologist or radiologist to support clinical decision making of cardiovascular conditions. The primary predicate device, 3mensio Workstation (K153736), is an earlier version of the current 3mensio Workstation product. The indications for use of the two devices are similar. The two products provide the same functionalities for advanced visualization and measurements of structures of the heart, heart valves and vessels to assist in pre-operational planning and sizing for cardiovascular interventions and surgery and postoperative evaluation. Additionally they both feature functionality for segmentation of cardiovascular structures, quantify dimensions and calcifications in coronary arteries and have measurement and annotation tools. All these functionalities are supported in both the new 3mensio Workstation product and the predicate device 3mensio Workstation (K153736). Therefore, the predicate device 3mensio Workstation (K153736) is selected as the primary predicate device. The differences in technological characteristics between the predicate device K153736 and the device 3mensio Workstation are that the new 3mensio Workstation runs from a web browser intended for usage in a network or cloud environment. Predicate device K153736 is only a standalone usage device. Furthermore, 3mensio Workstation includes calcium quantification of more cardiovascular structures than the predicate device K153736 which only included calcium quantification in the coronary arteries. In addition, the 3mensio Workstation includes machine learning (ML) features for some of the functionalities already available in the primary predicate device. Another difference between the previous generation of the 3mensio Workstation product, 3mensio Workstation (K153736) and the current device is a workflow for mitral valve analysis on 3D ultrasound images (3D US mitral valve). The selected secondary predicate device, TOMTEC-ARENA (K213544), offers similar functionality and is therefore selected as a secondary predicate device. Both software applications use the same types of data and operating principles for the user and technology regarding data import, analysis, image display and storage of results. A summary of the technological characteristics of the subject device and predicate devices is demonstrated in the Table below. | | Subject Device | Primary predicate device | Secondary predicate device | Comparison | | --- | --- | --- | --- | --- | | Device Name | 3mensio Workstation | 3mensio Workstation | TOMTEC | / | | 510(k) Number | K250330 | K153736 | K213544 | / | | Product Code | QIH, LLZ | LLZ | LLZ, QIH | Similar, the subject device implements AI/ML algorithms | | Classification | Medical image management and processing system | Medical image management and processing system | Medical image management and processing system | Same | | Regulation Number | 21 CFR 892.2050 | 21 CFR 892.2050 | 21 CFR 892.2050 | Same | | Intended Use | Standalone diagnostic bioimaging software is intended to measure and visualize cardiovascular structures. | 3mensio Workstation is a software solution that is intended to provide Cardiologists, Radiologists and Clinical Specialists additional information to aid them in reading and interpreting DICOM compliant medical images of structures of the heart and vessels. | TOMTEC-ARENA software is a clinical software package designed for review, quantification and reporting of structures and function based on multi-dimensional digital medical data acquired with different modalities. TOMTEC-ARENA is not intended to | Same, both the subject device and primary predicate device generally share the intended use to enable visualization and measurement of cardiovascular structures. | Pie Medical Imaging BV {6} PIE MEDICAL IMAGING 510(k) Summary – K250330 3mensio Workstation | | | 3mensio Structural Heart enables the user to: • Visualize and measure (diameters, lengths, areas, volumes, angles) structures of the heart and vessels • Quantify calcium (volume, density) 3mensio Vascular enables the user to: • Visualize and assess stenosis, aneurysms and vascular structures • Measure the dimensions of vessels (diameters, lengths, areas, volumes, angles) | be used for reading of mammography images. | | | --- | --- | --- | --- | --- | | Indications for Use | Standalone software for medical image analysis intended for advanced visualization and quantitative analysis for diagnostics in the field of cardiology or radiology by means of enabling visualization and measurement of the heart and vessels for: • Pre-operational planning and sizing for cardiovascular interventions and surgery • Postoperative evaluation • Support of clinical diagnosis by quantifying dimensions of coronary arteries • Support of clinical diagnosis by quantifying calcifications (calcium scoring) To facilitate the above, the 3mensio Workstation provides general functionality such as: • Segmentation of cardiovascular structures • Automatic and manual centerline detection • Visualization and image reconstruction techniques: 2D review, Volume Rendering, MPR, Curved MPR, Stretched CMPR, Slabbing, MIP, AIP, MinIP • Measurement and annotation tools • Reporting tools | 3mensio Workstation enables visualization and measurement of structures of the heart and vessels for: • Pre-operational planning and sizing for cardiovascular interventions and surgery • Postoperative evaluation • Support of clinical diagnosis by quantifying dimensions in coronary arteries To facilitate the above, the 3mensio Workstation provides general functionality such as: • Segmentation of cardiovascular structures • Automatic and manual centerline detection • Visualization and image reconstruction techniques: 2D review, Volume Rendering, MPR, Curved MPR, Stretched CMPR, Slabbing, MIP, AIP, MinI • Measurement and annotation tool • Reporting tools | Indications for use of TomTec-Arena TTA2 software are quantification and reporting of cardiovascular, fetal, abdominal structures and function of patients with suspected disease to support the physician in the diagnosis. | Same for the subject device and primary predicate device. Additionally, the subject device includes functionality for calcium quantification in in other cardiovascular structures then only coronary arteries. For the secondary predicate device, only quantification and reporting of cardiovascular structures is applicable for this comparison. Other anatomical structures are not relevant for the comparison. | | Anatomical Site | Segmentation, quantification, review, and reporting of cardiovascular structures | Segmentation, quantification, review, and reporting of cardiovascular structures | Segmentation, quantification, review, and reporting of cardiovascular, fetal and abdominal structures. | Same for the subject device and primary predicate device. For the secondary predicate device, only quantification and reporting | Pie Medical Imaging BV Page 3 of 5 {7} PIE MEDICAL IMAGING 510(k) Summary – K250330 3mensio Workstation | | | | | of cardiovascular structures is applicable for this comparison. Other anatomical structures are not relevant for the comparison. | | --- | --- | --- | --- | --- | | Design | Software as a medical device: standalone and web-based (on-premise and in the cloud) | Software as a medical device (standalone) | Software as a medical device (standalone) | The subject device can be deployed either standalone or web-based (on-premise and in the cloud) but this difference does not impact the intended use, indications for use, safety and performance of the device. Any risks related to web-based availability (both on-premise and in the cloud) are mitigated by cybersecurity measures. | | Data Import and Type | • Vendor independent • CT data in DICOM format • X-Ray data in DICOM format • Ultrasound data (2D and 3D) in DICOM format | • Vendor independent • CT data in DICOM format • X-Ray data in DICOM format • Ultrasound data (2D) in DICOM format | • Vendor independent • Ultrasound data (2D and 3D) in DICOM format | Same, the subject device includes data types of both predicate device combined. | | Data Management | • Study list overview • Deleting • Exporting • Anonymizing • Search | • Study list overview • Deleting • Exporting • Anonymizing • Search | Note: features not mentioned since they are not relevant for this comparison. | Same, the subject device and primary predicate device use the same types of data management functionality. | | Image Processing and Contour Definition | • Realign orthogonal MPR's • Segmentation toolset: - Automatic segmentation (both AI and non-AI) - Manual segmentation - Automatic centerline - Manual centerline - Growing centerline - Centerline editing • Volume sculpting | • Realign orthogonal MPR's • Segmentation toolset: - Automatic segmentation (non-AI) - Manual segmentation - Automatic centerline - Manual centerline - Growing centerline - Centerline editing Volume sculpting | Note: features not mentioned since they are not relevant for this comparison. | Both the subject and primary predicate device include automated and manual segmentation functionality and both devices include the option for the physician to review and edit the segmentation. The segmentation toolset in the subject device additionally includes ML features. | | Image Assessment | • Linear (length and diameter), area and angle measurements • Volume measurements • C-arm angulation calculation • Text, arrow and 3D annotations • Calcium scoring • Valve assessment | • Linear (length and diameter), area and angle measurements • Volume measurements • C-arm angulation calculation • Text, arrow and 3D annotations • Calcium scoring • Valve assessment | • Linear (length and diameter), area and angle measurements • Volume measurements • Text, arrow and 3D annotations | Same, the subject device and primary predicate device use the same image assessment functionality. Also the secondary predicate device uses relevant image assessment types for analysis of 3D ultrasound images. | | Image Display | • Orthogonal, oblique, double-oblique, curved, cross-curved, stretched MPR, curved MPR views • MIP, AIP, MinIP and color volume slabs • Volume rendering • 2D slice review and stack comparison • 4D cine • Multi-tissue color and opacity control • Virtual device displays | • Orthogonal, oblique, double-oblique, curved, cross-curved, stretched MPR, curved MPR views • MIP, AIP, MinIP and color volume slabs • Volume rendering • 2D slice review and stack comparison • 4D cine • Multi-tissue color and opacity control Virtual device displays | • Oblique, double-oblique views • Volume rendering • 4D cine | Same, both the subject device and primary predicate device use the same types of image display. The secondary predicate device uses relevant image display features for analysis of 3D ultrasound images. | | Storage and Export of Results | Session states PDF reports | Session states PDF reports | Not relevant for comparison. | Same. | Pie Medical Imaging BV Page 4 of 5 {8} PIE MEDICAL IPRIGHTS 510(k) Summary – K250330 3mensio Workstation # V - Performance Data Verification and validation of the 3mensio Workstation showed that the system requirements – derived from the indications for use and defined user needs – as well as risk control measures were implemented correctly, and that the device meets its specifications including conformance to the international recognized process standards (i.e., ISO 13485, ISO 14971, IEC 62304, IEC 62366-1, and IEC 82304-1). Documentation is provided as recommended by FDA’s Guidance “Guidance for the Content of Premarket Submissions for Software Contained in Medical Devices” and verification and validation was performed per the FDA Guidance “Technical Performance Assessment of Quantitative Imaging in Radiological Device Premarket Submission”. Performance testing was conducted where the results of automatically determined segmentation and measurements was evaluated against ground-truth values manually obtained by experts with the primary predicate device. The results showed high accuracy and agreement with the predicate device, meeting all predefined acceptance criteria. The performance tests included statistical methods such as Bland-Altman analysis, intraclass correlation coefficient (ICC) calculations and Dice coefficient. ## Testing Characteristics The performance testing was based upon a multi-centric observational cohort study involving MSCT datasets of 65 patients indicated for valvular intervention. The cohort comprised of at least 50% datasets from USA. The age range of the studied cohort was 38-99 years, with 50% female subjects. The cohort included CT scans from different CT manufacturers and covered imaging parameters such as different slice thickness and contrast enhancement. No datasets were included that were used for training the machine learning models. ## Testing Methodology and Statistical Approach The accuracy of the automatically determined segmentations was evaluated using Dice scores. The segmentations covered various cardiovascular structures including the aortic nadir positions, mitral annulus plane tricuspid annulus. The accuracy of automatically determined measurements was evaluated using Bland-Altman analysis and the intraclass correlation coefficient (ICC). ## Segmentation Results The resulting Dice scores ranged from 0.94 ± 0.07 for the mitral annulus, 0.87 ± 0.12 for the tricuspid annulus. The average distance from the automatically detected nadir positions towards the ground truth annular plane was -/- 0.64 ± 1.07 mm. These values demonstrate that a high accuracy is achieved for the automatically determined segmentations meeting the pre-defined acceptance criteria. ## Measurements Results: The ICC values were 0.99 for the measurements on the aortic annulus plane derived from the aortic nadir positions, 0.94 and above for the measurements on the mitral annulus and 0.97 and above for the measurements on the tricuspid annulus indicating excellent agreement with the ground-truth values obtained by experts. Bland-Altman analysis shows excellent agreement between the automatically determined measurements and the measurements obtained by experts. Based on the above it can be concluded that the automatically determined segmentations and measurements are as accurate and reliable as those obtained using the predicate device. Overall, comparable performance was achieved on all variability factors including geographic location, scanners, slice thickness, age, and gender. The verification and validation results demonstrate the safety and effectiveness of 3mensio Workstation in relation to its intended use and indications for use and therefore 3mensio Workstation can be considered as safe and effective as its predicate devices. # VI - Conclusion Based on the application of risk management and performance testing inherent to PMI’s QA system (compliant with recognized standards as stated above) the conclusion is that 3mensio Workstation is as safe and effective as its predicate device in terms of indications for use, technological characteristics, measurements, and operating environment and does not raise any new issues related to safety and effectiveness compared to the predicate devices. Pie Medical Imaging BV
Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...